O ~{
30,000 DWT LAKE-SIZE DOUBLE-SKIN BULK CARRIER
DETAIL DESIGN
30000DWT 'YVnWSóXce'ć9
ć Ć~ Ą
SC4447(MD)-474-01
WEIGHT
NUM. REVISION NO. SIGN SCALE
MARKS DATE COR. MARKS
F.W.GENERATOR SYSTEM
peę O9eUSS ~{W[ ęę (kg)
h eg V7hh kO
DESIGNED DATE
590
TYPICAL
~ Y[źń eg
6Rmňn|~
CHECK DATE
TOT.AREA PAGE uŚ
1 / 6
0.4375m2
R'YR
!hł[ eg
;`by pe
VERIFIED DATE
SHANGHAI MERCHANT SHIP
e^V{vS
R'YR
Ą[8h eg DESIGN&RESEARCH INSTITUTE,CSSC
APPROVED DATE -N żV 9 6
Nwm96xvzĄb
]NĆ
VlQłS
ybĆQ ?bl eg
^V{vS
This drawing and the information contained is the exclusive property of SDARI and must not be copied or handed over
to third parties without our written permission.
,gVeN ĘS@b+TQą["vwĆżNCg^\N
Nwm96xvzĄb
SDARI 0*g~,gb
fNbSNUON
N_
Y6RblŹńN,{ Nąe0
PAGE
F.W.GENERATOR SYSTEM
SC4447(MD)-474-01
6Rmňn|~
2 / 6
NOTE:
1 ANNOTATED SIZES OF PIPES IN THE DRAWING TO BE DIAMETER X THICK (mm).
2 MATERIAL OF PIPING:
SEA WATER & FRESH WATER PIPE ---- GALV. SEAMLESS STEEL PIPE
COOLING FRESH WATER PIPE ---- SEAMLESS STEEL PIPE
GAUGE PIPE ---- COPPER PIPE
3 PRESSURE TEST: (MPa)
PIPE DESIGN PRESSURE SHOP(HYDR.) TEST BOARD(AIR) TEST
S.W. PUMP OUTLET 0.462 0.693
NO LEAKAGE
F.W. PUMP OUTLET // UNDER WORK
CONDITION
DRAIN //
OTHER PIPE REFER TO THE REQUIREMENTS OF RELEVANT SYSTEM .
4 PRESSURE GAUGE AND COMPOUND GAUGE TO BE WITH COCK.PRESSURE SENSOR
TO BE WITH TEST COCK. THERMOMETER TO BE WITH PROTECTION WELL.
5 AFTER BEING FITTED ON BOARD ,EACH LINE IN THE SYSTEM TO BE BLOWN OUT BY
COMPRESSED AIR.
6 WHERE PIPES PENETRATE THROUGH WATER TIGHT BULKHEADS OR DECKS, TO BE FITTED WITH
PENETRATION PIECES ACCORDING CB/T3480-92 (ISO FLANGE) OR SHIPYARD STANDARD.
7 THE PIPES TO BE SUPPORTED SECURELY ACCORDING TO CB/T3780-97 EVERY 2~3M IN
ORDER TO PREVENT DAMAGES FROM VIBRATION.
8 THE VALVES, FITTINGS AND PIPING IN DOUBLE DASH-DOTTED LINE TO BE SUPPLIED WITH
EQUIPMENTS.
AREA:0.0625m2
PAGE
F.W.GENERATOR SYSTEM
SC4447(MD)-474-01
6Rmňn|~
3 / 6
f
1 V-N@bŁlĄ{P[:\ł[:NY"_xXS(mm)
2 Ą{|Pge
wm4lĄ{ & m4lĄ{
ąeó"Ą{@
m4lQtSĄ{
ąeó"Ą{
ęNhĄ{
+}"Ą{
3 mSՋŚ: (MPa)
Ą{ć ĄSR fŹmS ň9
0.462 0.693
wm4llłcśQćS
//
m4llłcśQćS ]\O`QNąelo
//
l>eĄ{ć
vQYOĄ{ćՋŚSRSłv"^T|~Bl
4 SRh0wzzSRh&^KQSR_sQ&^ NՋŚKQ)nŚ^Ą&^ŻOńbi
5 |~[ňŚ[NT|~Ą{ć(uS)zzlQm
6 Ą{P[Ź4lĆ[2ugb1Xe"^ cCB/T 3480-92(ISOlpQ)b9ShĆQn1Ą{N
7 Ą{P[k"
2~3 cCB/T3780-97MęnĄ{9YŚT
TśgNMQąV/cR@b_wć"v_cOW
8 V-NSąpRż~Q
0D
NĘSĄ{ć1uYFUO0
AREA:0.0625m2
PAGE
30,000 DWT LAKE-SIZE DOUBLE-SKIN BULK CARRIER F.W.GENERATOR SYSTEM
SC4447(MD)-474-01
30000DWT 'YVnWSóXce'ć9
4 / 6
6Rmňn|~
VALVE OR FITTINGS PLATE
DN. PN.
No. MARK
b D
N MATE'L QTY. WE'T STAD. NAMEPLATE LETTERING REMARK
lQy lQy
TYPE/ STANDARD NAME
Ź^S S "_ SR Pg e peę ęę "LrhĆQ " Lr ;R W[ Y Łl
mm MPa kg S
WS0hĆQSbVS
T y
BUTT. VALVE CAST IRON A45-13H
FGV01 100 1 1 F.W. GENERATOR S.W.FILTER INLET
1
CB/T84-1998
ł""
v
BUTT. VALVE CAST IRON
A45-13H
FGV02 100 1 1 F.W. GENERATOR S.W.PUMP INLET
2
CB/T84-1998
ł""
v
STOP CHECK VALVE CAST IRON F.W.GENERATOR S.W. PUMP
A45-13H
FGV03 AS10080 GB/T591-93 80 1 1 25.6
3
CB/T84-1998
ł"" DISCHARGE
*bbkbkV
STOP VALVE BRONZE B50-8H
FGV04 AS25025 GB/T587-93 20 2.5 1 6.2 F.W.GENERATOR F.W. OUTLET
4
CB/T84-1998
R"
*bbk
STOP CHECK VALVE CAST STEEL F.W.GENERATOR S.W. BRINE
A45-13H
FGV05 AS6080 GB/T1853-94 80 0.6 1 24.9 DNV CERT.
5
CB/T84-1998
ł"ó" OVERBOARD
*bbkbkV
BUTT. VALVE CAST IRON A45-13H
FGV06 80 1 1 S.W.BRINE & AIR OUTLET
6
CB/T84-1998
ł""
v
SEA WATER FILTER
FGF01 AS100 CB/T497-94 100 0.1 Q235-A 1 38.4 2mm
7
8TeQ|4lnhV
ASSEMBLY SEA WATOR P.INLET FOR
YZT-100CII -0.1~0.16MPa PRESS. V. GAUGE & VALVE
FGF02 6 4 1 0.72
8
A40006 CB312-75 SRwzzhĘS
~TN
F.W.GENERATOR
YT-100CII 0~0.6MPa PRESS. GAUGE VALVE ASSEMBLY SEA WATOR P.OUTLET FOR
FGF03 6 4 1 0.72
9
A40006 CB312-75 ~TN
SRhĘS
F.W.GENERATOR
YT-100CII 0~0.6MPa PRESS. GAUGE VALVE ASSEMBLY
FGF04 6 4 1 0.72
10 EJECTOR TO OVERBOARD
A40006 CB312-75 ~TN
SRhĘS
THERMOMETER ASSEMBLY
FGF05
11 WNG-11, 0-100! G3/4" 1 0.5
EJECTOR TO OVERBOARD
~TN
)nŚ^h
THERMOMETER ASSEMBLY
FGF06
12 WNG-11, 0-100! G3/4" 1 0.5
JACKET WATER OUTLET
~TN
)nŚ^h
THERMOMETER ASSEMBLY
FGF07
13 WNG-11, 0-100! G3/4" 1 0.5
JACKET WATER INLET
~TN
)nŚ^h
PAGE
F.W.GENERATOR SYSTEM
30,000 DWT LAKE-SIZE DOUBLE-SKIN BULK CARRIER
SC4447(MD)-474-01
30000DWT 'YVnWSóXce'ć9
6Rmňn|~
5
/ 6
Test App. Conn. Connectio
DN.
Thick-
Weight
Description
4lSՋŚ(Mpa) Remark
No. O.D. Y Materail Length Qty. n Standard
lQy ness
Bef Instal. Aft Instal.
Ź^S
T y "_ "_ mm XS Pg e ŃŹ
ŹĄcN ŹĄcNh
ęękg
Ś^(m)
mm mm Npe ĆQ
ň9MR ň9T
Galv.Seamless.St.
1 SEA WATER PIPE wm4lĄ{ 100 114 5 10 134.4 #20 GB8163-87
@ąeó"Ą{
Galv.Seamless.St.
2 SEA WATER PIPE wm4lĄ{ 80 89 4.5 25 234.5 #20 GB8163-87
@ąeó"Ą{
Seamless St. ąe
F.W.COOLING PIPE m4lQtSĄ{
3 80 89 3.5 10 73.8 #20 GB8163-87
ó"Ą{
Galv.Seamless.St.
4 F.W.PIPE m4lĄ{ 20 27 2.5 10 15.1 #20 GB8163-87
@ąeó"Ą{
Galv.Seamless.St.
5 F.W.PIPE m4lĄ{ 15 22 2.5 10 12.0 #20 GB8163-87
@ąeó"Ą{
COPPER
66 8 1 2 0.3 T2 ZB U50 001-90
GAUGE PIPE ęNhĄ{
+}"Ą{
470.2
TOTAL: 470.2 Kg
Wyszukiwarka
Podobne podstrony:
Wind Turbine Generator Systems – Wind Turbine Power Performance Testing
01 Linux Start systemu i związanie z nim procesy
Bertalanffy The History and Status of General Systems Theory
CEI 61400 22 Wind turbine generator systems Required Design Documentation
01 Wiadomości ogólne o systemie elektroenergetycznym
110639 an 01 pl Generator wiatrowy?3 Rutland
IEC 61400 11 Wind turbine generator systems en
monter systemow rurociagowychq3[04]? 01 n
01 06 Systemy liczbowe
monter systemow rurociagowychq3[04] z1 01 n
System sterowania generatorów
Cwiczenie 01 Instalowanie systemu Windows 2003
712[06] S1 01 Rozpoznawanie materiałów stosowanych w systemach suchej zabudowy wnętrz
Cisco Broadband Operating System Chapter 01
więcej podobnych podstron