EV–100ZX SCR MOTOR CONTROLLER,
Parameter Tables
REGISTER PARAMETERS
General
This section must be used with the following sections of
this motor controller:
•
EV–100ZX SCR MOTOR CONTROLLER,
Description, Adjustments, Troubleshooting,
Repairs, and Theory, 2200 SRM 557
•
TROUBLESHOOTING AND ADJUST-
MENTS WITH A COMPUTER For
EV–100ZX And EV–T100 Motor Controllers,
2200 SRM XXX
The “ZX” series of control cards have an electronic de-
vice called an EEPROM (Electrically–Erasable–Pro-
grammable–Read–Only–Memory). The EEPROM has
a number of memory elements called registers. These
registers can have electronic data stored in them to con-
trol an operation. The range of data that can be stored in
the registers is called a parameter. A parameter is a
measurement number that works with other measure-
ment numbers (parameters) to define a system. The EE-
PROM in the control card is a control system for the op-
eration of the lift truck.
The EEPROM used in the “ZX” series of control cards
has 128 registers.
WARNING
Each register in each control card has a range of
numbers so that the control card can be used on dif-
ferent models of lift trucks. This variation is needed
for lift trucks of different sizes and operating volt-
ages. Adjustment of the register to the wrong num-
ber for your lift truck model can cause the truck to
operate differently than normal. This different oper-
ation of the truck can cause an injury.
Do NOT adjust any of the registers without using the
parameters shown in EV–100ZX SCR MOTOR
CONTROLLER, Parameter Tables, 2200 SRM
XXX.
NOTE: The Parameter Tables show the permitted
ranges and the default setting for each control function.
The Factory Set Parameters are the recommended set-
tings for new units. These settings will give satisfactory
performance for most applications.
Some functions can be adjusted within the permitted
range to change the lift truck operation for a specific
application. Adjustment of a register to a number that is
different than the factory setting is allowed, but follow
the instructions carefully and stay within the minimum
and maximum limits. Adjustments other than the facto-
ry settings will cause the lift truck to operate differently
and can cause increased wear of parts.
Function Numbers
The Function Numbers are code numbers for the differ-
ent parameters that can be set for the “ZX” series control
cards. The Personal Computer or the Hand Set must be
used to adjust the parameters for the control card. There
is a description of the code numbers for the different
control cards in the Parameter Tables. These Parame-
ter Tables have the correct setting numbers for the pa-
rameters on each control card.
CONTROL CARD, CHECKS AND
ADJUSTMENTS
A Personal Computer (PC) or a Hand Set is used to per-
mit Authorized Personnel to make the following
checks and adjustments:
•
Check the system status codes for both traction
and hydraulic pump SCR systems
•
Check for status codes that are not regular nor
constant
•
Check the state of charge of the battery on motor
controllers with type ZH and ZY control cards
•
Check the hourmeter readings on the traction cir-
cuit and hydraulic pump SCR controllers
•
Monitor or adjust the following control func-
tions:
♦
Creep Speed
♦
Controlled Acceleration and 1A Time
♦
Current Limit
♦
Steering pump time delay and define signal
input (seat switch or directional switch)
2
♦
Plugging distance (Current)
♦
Accelerator pedal position, plug range or
disable
♦
1A drop out current or disable
♦
Field Weakening drop–out
♦
Field Weakening pick–up
♦
Regenerative Braking current limit
♦
Regenerative Braking drop–out
♦
Speed limit points (SL1, SL2 and SL3)
♦
Internal resistance compensation for battery
state of charge indication
♦
Battery voltage (36/48V is auto ranging)
•
Selection of type of card operation:
♦
Traction circuit with Field Weakening
♦
Traction circuit with Regenerative Braking
and Field Weakening
♦
High or low current limit for all of the above
functions
REGISTER PARAMETERS
(See TABLE 1. through TABLE 7.)
Parameters must be between the minimum and maxi-
mum numbers shown. Do NOT adjust a parameter to a
number that is not shown in the correct table. Make sure
you use the correct table when you make adjustments. It
is a good procedure to check the parameter and compare
the parameter to the number in the table before making
the adjustment. The factory parameter, and the value
(current, time, etc.) for that parameter, are shown in the
columns indicated as Default. The minimum and maxi-
mum parameters and their values are shown in the col-
umns indicated as Permitted Range.
NOTE: Check the label at the top edge of each card case
to identify the control card on your lift truck. There are
some painted letters and numbers followed by other
numbers and letters on the lower part of the label. The
last two letters on the lower part identify the TYPE of
card installed. The table titles show these card types for
the EV–100ZX motor controllers.
3
TABLE 1. EV–100ZX Parameters – E/J2.00–3.20XM (E/J45–65XM) and N30XMH (36 to 48V)
(Traction Card Type ZH With Regenerative Braking and Field Weakening)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
1
Stored Statue Code
0
1
—
0
1
/255
—
1
Any number other than “zero” can be read as a possible fault.
2
Creep Speed
[E2.00–3.20XM (E45–65XM)]
20
5%
0/255
5% to 15%
2
Creep Speed
[J2.00–3.20XM (J45–65XM)]
0
5%
0/255
5% to 15%
3
Controlled Acceleration and 1A
Time
20
1.8 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
255
max. amp
0/255
max. amperes
5
Plugging Distance (Current)
100
514 amp
0/105
200 to 530 amperes
6
1A Drop–Out Current
138
900 amp
0/250
2
450 to 1260 amperes
2
Settings greater than 250 will disable the 1A Drop–Out function
7
Field Weakening Pick–Up
(Current)
36
110 amp
0/110
110 to 228 amperes
8
Field Weakening Drop–Out
(Current)
130
487 amp
0/140
65 to 520 amperes
9
Regenerative Braking Current
Limit
115
328 amp
0/143
75 to 390 amperes
10
Regenerative Braking Start
(% ON time)
80
30%
0/255
0 to 95% SCR ON time
11
Speed Limit 1 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum motor
speed, Voltage with NC switch
open)
120
64% of
batt. volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
20
3
—
5/25
—
3
Average value for most batteries. See procedure for more accurate value.
15
Battery Volts
200
36/48 V
184/250
36 or 48 volt operation
16
Pedal Position Plugging
40
228 amp
0/134
100 to 530 amperes
17
Card Type Selection
–
42
–
Plugging
Regen.
FW
40
42
44
Select control card with
correct functions:
Plugging only
Regenerative Braking
Field Weakening
4
Type ZH (36 to 48V) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
18
Steering Pump Time Delay
(Seat Switch)
0
25
4
1.5 sec
14 sec
4
0/128
21/128
4
1.5 to 65 sec
12 to 65 sec (Note
4
)
4
Setting of 21 (12 seconds) minimum without seat brake.
19
Maintenance Alert (hours)
0
0 to 99
20
Maintenance Alert (hours)
99
100 to 9900
21
Maintenance Speed Limit
99
None
0
180
22
Mode Reference (Reference
register for the instrument panel
display when the battery is
connected.)
0
None
None
—
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
—
None
(Temporary storage
register.)
26
Monitor Register
0
—
None
(Temporary storage
register.)
27
Battery Volts Data
—
—
None
(Temporary storage register
for battery voltage data.)
28
Fault Count Pointer
(Must be reset to zero to clear
Status Codes)
—
—
None
(Temporary storage register
that points to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0–99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
Function Numbers 31 through 47 can be read and cleared with a Hand Set. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can only be
reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62
enable the lift truck to be set to four performance levels by the
operator. (If the customer does not want this function available to the operator, a service person can
set all four levels to the same setting.) Each time the operator pushes the button on the instrument
panel, the performance level will increase by one step. At the maximum (rabbit) level, the
performance levels will begin at the lowest (turtle) level again.
Fcn.
No.
Minimum
Parameter
Maximum Parameter
MODE 1
48
Controlled Acceleration
40
3.5 sec
Fcn. No. 52
255
49
FW Pick–Up Current
0
None
0
Fcn. No. 53
50
Speed Limit 1
85
80%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
30
2.6 sec
Fcn. No. 56
Fcn. No. 48
5
Type ZH (36 to 48V) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
53
FW Pick–Up Current
0
None
Fcn. No. 49
Fcn. No. 57
54
Speed Limit 1
0
None
Fcn. No. 58
Fcn. No. 50
55
Not Used
MODE 3
56
Controlled Acceleration
20
1.8 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick–Up Current
36
110 amps
Fcn. No. 53
Fcn. No. 61
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
MODE 4
60
Controlled Acceleration
10
0.94 sec
8
Fcn. No. 56
61
FW Pick–Up Current
83
185 amps
Fcn. No. 57
110
62
Speed Limit 1
0
None
0
Fcn. No. 107
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter
(thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter
(tens/units)
Read Only
Secure Auxiliary Hourmeter
(thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by
user (tens/units)
0 to 99
Lift truck number assigned by
user (thousands/hundreds)
100 to 9900
6
TABLE 2. EV–100ZX Parameters – E2.00–3.20XM (E45–65XM) and N30XMH (36 to 48V)
(Traction Card Type ZY NO Regenerative Braking and NO Field Weakening)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
1
Stored Statue Code
0
1
—
0
1
/255
—
1
Any number other than “zero” can be read as a possible fault.
2
Creep Speed
0
5%
0/255
5% to 15%
3
Controlled Acceleration and 1A
Time
20
1.8 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
255
max. amp
0/255
max. amperes
5
Plugging Distance (Current)
65
400 amp
0/70
200 to 416 amperes
6
1A Drop–Out Current
77
700 amp
0/250
2
450 to 1260 amperes
2
Settings greater than 250 will disable the 1A Drop–Out function
7
Field Weakening Pick–Up
(Current)
N/A
N/A
N/A
N/A
8
Field Weakening Drop–Out
(Current)
N/A
N/A
N/A
N/A
9
Regenerative Braking Current
Limit
N/A
N/A
N/A
N/A
10
Regenerative Braking Start
(% ON time)
N/A
N/A
N/A
N/A
11
Speed Limit 1 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum motor
speed, Voltage with NC switch
open)
120
64% of
batt. volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
20
3
—
5/25
—
3
Average value for most batteries. See procedure for more accurate value.
15
Battery Volts
200
36/48 V
184/250
36 or 48 volt operation
16
Pedal Position Plugging
40
228 amp
0/134
100 to 530 amperes
17
Card Type Selection
2
2
Select control card with
correct functions:
Plugging only
18
Steering Pump Time Delay
(Seat Switch)
0
25
4
1.5 sec
14 sec
4
0/128
21/128
4
1.5 sec to 65 sec
12 sec to 65 sec (Note
4
)
4
Setting of 21 (12 seconds) minimum without seat brake.
19
Maintenance Alert (hours)
99
0 to 99
7
Type ZY (36 to 48V) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
20
Maintenance Alert (hours)
99
100 to 9900
21
Maintenance Speed Limit
0
None
0
180
22
Mode Reference (Reference
register for the instrument panel
display when the battery is
connected.)
—
None
None
—
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
—
None
(Temporary storage
register.)
26
Monitor Register
0
—
None
(Temporary storage
register.)
27
Battery Volts Data
—
—
None
(Temporary storage register
for battery voltage data.)
28
Fault Count Pointer
(Must be reset to zero to clear
Status Codes)
—
—
None
(Temporary storage register
that points to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0–99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
Function Numbers 31 through 47 can be read and cleared with a Hand Set. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can only be
reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62
enable the lift truck to be set to four performance levels by the
operator. (If the customer does not want this function available to the operator, a service person can
set all four levels to the same setting.) Each time the operator pushes the button on the instrument
panel, the performance level will increase by one step. At the maximum (rabbit) level, the
performance levels will begin at the lowest (turtle) level again.
Fcn.
No.
Minimum
Parameter
Maximum Parameter
MODE 1
48
Controlled Acceleration
40
3.5 sec
Fcn. No. 52
255
49
FW Pick–Up Current
0
N/A
0
N/A
50
Speed Limit 1
85
80%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
30
2.6 sec
Fcn. No. 56
Fcn. No. 48
53
FW Pick–Up Current
0
None
Fcn. No. 49
Fcn. No. 57
54
Speed Limit 1
0
None
Fcn. No. 58
Fcn. No. 50
55
Not Used
8
Type ZY (36 to 48V) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
MODE 3
56
Controlled Acceleration
20
1.8 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick–Up Current
0
Fcn. No. 53
Fcn. No. 61
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
MODE 4
60
Controlled Acceleration
10
0.94 sec
8
Fcn. No. 56
61
FW Pick–Up Current
0
Fcn. No. 57
110
62
Speed Limit 1
0
None
0
Fcn. No. 58
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter
(thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter
(tens/units)
Read Only
Secure Auxiliary Hourmeter
(thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by
user
Lift truck number assigned by
user
9
TABLE 3. EV–100ZX Parameters – E/J2.00–3.20XM (72 to 80V)
(Traction Card Type ZH With Regenerative Braking and Field Weakening)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
1
Stored Statue Code
0
1
—
0
1
/255
—
1
Any number other than “zero” can be read as a possible fault.
2
Creep Speed
0
5%
0/255
5% to 15%
3
Controlled Acceleration and 1A
Time
20
1.8 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
125
0/130
5
Plugging Distance (Current)
50
357 amp
0/55
200 to 373 amperes
6
1A Drop–Out Current
12
489 amp
0/250
2
450 to 1260 amperes
2
Settings greater than 250 will disable the 1A Drop–Out function
7
Field Weakening Pick–Up
(Current)
22
88 amp
0/36
0 to 110 amperes
8
Field Weakening Drop–Out
(Current)
55
244 amp
0/60
65 to 260 amperes
9
Regenerative Braking Current
Limit
50
185 amp
0/55
75 to 196 amperes
10
Regenerative Braking Start
(% ON time)
10
3.70%
0/255
0 to 95% SCR ON time
11
Speed Limit 1 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum motor
speed, Voltage with NC switch
open)
120
64% of
batt. volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
12
3
—
5/25
—
3
Average value for most batteries. See procedure for more accurate value.
15
Battery Volts
75
72 V
70/80
72 volt operation
15
Battery Volts
85
80 V
81/183
80 volt operation
16
Pedal Position Plugging
40
228 amp
0/85
100 to 373 amperes
17
Card Type Selection
42
Plugging
Regen.
FW
40
42
44
Select control card with
correct functions:
Plugging only
Regenerative Braking
Field Weakening
18
Steering Pump Time Delay
(Seat Switch)
25
14 sec
0/128
1.5 to 65 seconds
19
Maintenance Alert (hours)
99
0 to 99
10
Type ZH (72 to 80V) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
20
Maintenance Alert (hours)
99
100 to 9900
21
Maintenance Speed Limit
0
None
None/0
None to 180
22
Mode Reference (Reference
register for the instrument panel
display when the battery is
connected.)
—
None
None
—
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
—
None
(Temporary storage
register.)
26
Monitor Register
0
—
None
(Temporary storage
register.)
27
Battery Volts Data
—
—
None
(Temporary storage register
for battery voltage data.)
28
Fault Count Pointer
(Must be reset to zero to clear
Status Codes)
—
—
None
(Temporary storage register
that points to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0–99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
Function Numbers 31 through 47 can be read and cleared with a Hand Set. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can only be
reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62
enable the lift truck to be set to four performance levels by the
operator. (If the customer does not want this function available to the operator, a service person can
set all four levels to the same setting.) Each time the operator pushes the button on the instrument
panel, the performance level will increase by one step. At the maximum (rabbit) level, the
performance levels will begin at the lowest (turtle) level again.
Fcn.
No.
Minimum
Parameter
Maximum Parameter
MODE 1
48
Controlled Acceleration
40
3.5 sec
Fcn. No. 52
255
49
FW Pick–Up Current
0
None
0
Fcn. No. 53
50
Speed Limit 1
85
80%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
30
2.6 sec
Fcn. No. 56
Fcn. No. 48
53
FW Pick–Up Current
0
None
Fcn. No. 49
Fcn. No. 57
54
Speed Limit 1
0
None
Fcn. No. 58
Fcn. No. 50
55
Not Used
11
Type ZH (72 to 80V) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
MODE 3
56
Controlled Acceleration
20
1.8 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick–Up Current
[E2.00–3.20XM (E45–65XM)]
22
88 amps
Fcn. No. 53
Fcn. No. 61
57
FW Pick–Up Current
[J2.00–3.20XM (J45–65XM)]
29
99 amps
Fcn. No. 53
Fcn. No. 61
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
MODE 4
60
Controlled Acceleration
10
0.94 sec
8
Fcn. No. 56
61
FW Pick–Up Current
36
110 amps
Fcn. No. 57
110
62
Speed Limit 1
0
None
0
Fcn. No. 58
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter
(thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter
(tens/units)
Read Only
Secure Auxiliary Hourmeter
(thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by
user (tens/units)
0 to 99
Lift truck number assigned by
user (thousands/hundreds)
100 to 9900
12
TABLE 4. EV–100ZX Parameters – E2.00–3.20XM (72 to 80V)
(Traction Card Type ZY With Regenerative Braking and NO Field Weakening)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
1
Stored Statue Code
0
1
—
0
1
/255
—
1
Any number other than “zero” can be read as a possible fault.
2
Creep Speed
0
5%
0/255
5% to 15%
3
Controlled Acceleration and 1A
Time
20
2.6 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
125
max. amp
0/130
max. amperes
5
Plugging Distance (Current)
50
357 amp
0/55
200 to 374 amperes
6
1A Drop–Out Current
12
489 amp
0/250
2
450 to 1260 amperes
2
Settings greater than 250 will disable the 1A Drop–Out function
7
Field Weakening Pick–Up
(Current)
N/A
N/A
N/A
N/A
8
Field Weakening Drop–Out
(Current)
N/A
N/A
N/A
N/A
9
Regenerative Braking Current
Limit
50
0/125
75 to 349 amp
10
Regenerative Braking Start
(% ON time)
10
3.70%
0/255
0% to 96% of battery
voltage
11
Speed Limit 1 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum motor
speed, Voltage with NC switch
open)
120
64% of
batt. volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
12
3
—
5/25
—
3
Average value for most batteries. See procedure for more accurate value.
15
Battery Volts
75
72 V
70/80
72 volt operation
15
Battery Volts
85
80 V
81/183
80 volt operation
16
Pedal Position Plugging
40
228 amp
0/85
100 to 373 amperes
17
Card Type Selection
42
42
Select control card with
correct functions:
Regen. Braking
18
Steering Pump Time Delay
(Seat Switch)
25
14 sec
0/128
1.5 to 65 seconds
19
Maintenance Alert (hours)
99
0 to 99
20
Maintenance Alert (hours)
99
100 to 9900
13
Type ZY (72 to 80V) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
21
Maintenance Speed Limit
0
None
0
180
22
Mode Reference (Reference
register for the instrument panel
display when the battery is
connected.)
—
None
None
—
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
—
None
(Temporary storage
register.)
26
Monitor Register
0
—
None
(Temporary storage
register.)
27
Battery Volts Data
—
—
None
(Temporary storage register
for battery voltage data.)
28
Fault Count Pointer
(Must be reset to zero to clear
Status Codes)
—
—
None
(Temporary storage register
that points to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0–99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
Function Numbers 31 through 47 can be read and cleared with a Hand Set. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can only be
reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62
enable the lift truck to be set to four performance levels by the
operator. (If the customer does not want this function available to the operator, a service person can
set all four levels to the same setting.) Each time the operator pushes the button on the instrument
panel, the performance level will increase by one step. At the maximum (rabbit) level, the
performance levels will begin at the lowest (turtle) level again.
Fcn.
No.
Minimum
Parameter
Maximum Parameter
MODE 1
48
Controlled Acceleration
40
3.5 sec
Fcn. No. 52
255
49
FW Pick–Up Current
0
N/A
0
N/A
50
Speed Limit 1
85
80%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
30
2.6 sec
Fcn. No. 56
Fcn. No. 48
53
FW Pick–Up Current
0
None
Fcn. No. 49
Fcn. No. 57
54
Speed Limit 1
0
None
Fcn. No. 58
Fcn. No. 50
55
Not Used
14
Type ZY (72 to 80V) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
MODE 3
56
Controlled Acceleration
20
1.8 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick–Up Current
0
Fcn. No. 53
Fcn. No. 61
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
MODE 4
60
Controlled Acceleration
10
0.94 sec
8
Fcn. No. 56
61
FW Pick–Up Current
0
Fcn. No. 57
110
62
Speed Limit 1
0
None
0
Fcn. No. 58
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter
(thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter
(tens/units)
Read Only
Secure Auxiliary Hourmeter
(thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by
user
Lift truck number assigned by
user
15
TABLE 5. EV–100ZX Parameters – E2.00–3.20XM (72 to 80V) (Low Energy Usage)
(Traction Card Type ZY With 9–inch Motor, Regenerative Braking and NO Field Weakening)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
1
Stored Statue Code
0
1
—
0
1
/255
—
1
Any number other than “zero” can be read as a possible fault.
2
Creep Speed
0
5%
0/255
5% to 15%
3
Controlled Acceleration and 1A
Time
30
2.6 sec
8/255
0.77 to 22 seconds
4
Current Limit (C/L)
125
max. amp
0/130
max. amperes
5
Plugging Distance (Current)
50
357 amp
0/55
200 to 373 amperes
6
1A Drop–Out Current
12
489 amp
0/250
2
450 to 1260 amperes
2
Settings greater than 250 will disable the 1A Drop–Out function
7
Field Weakening Pick–Up
(Current)
N/A
N/A
N/A
N/A
8
Field Weakening Drop–Out
(Current)
N/A
N/A
N/A
N/A
9
Regenerative Braking Current
Limit
50
185 amp
0/55
75 to 196 amp
10
Regenerative Braking Start
(% ON time)
10
3.70%
0/255
0% to 96% of battery
voltage
11
Speed Limit 1 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum motor
speed, Voltage with NC switch
open)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum motor
speed, Voltage with NC switch
open)
120
64% of
batt. volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
12
3
—
5/25
—
3
Average value for most batteries. See procedure for more accurate value.
15
Battery Volts
75
72 V
70/80
72 volt operation
15
Battery Volts
85
80 V
81/183
80 volt operation
16
Pedal Position Plugging
40
228 amp
0/85
100 to 373 amperes
17
Card Type Selection
42
42
Select control card with
correct functions:
Regen. Braking
18
Steering Pump Time Delay
(Seat Switch)
25
14 sec
0/128
1.5 to 65 seconds
19
Maintenance Alert (hours)
99
0 to 99
20
Maintenance Alert (hours)
99
100 to 9900
16
Type ZY [9–inch Motor (Continued)]
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
21
Maintenance Speed Limit
0
None
0
180
22
Mode Reference (Reference
register for the instrument panel
display when the battery is
connected.)
—
None
None
—
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
—
None
(Temporary storage
register.)
26
Monitor Register
0
—
None
(Temporary storage
register.)
27
Battery Volts Data
—
—
None
(Temporary storage register
for battery voltage data.)
28
Fault Count Pointer
(Must be reset to zero to clear
Status Codes)
—
—
None
(Temporary storage register
that points to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0–99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
Function Numbers 31 through 47 can be read and cleared with a Hand Set. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can only be
reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62
enable the lift truck to be set to four performance levels by the
operator. (If the customer does not want this function available to the operator, a service person can
set all four levels to the same setting.) Each time the operator pushes the button on the instrument
panel, the performance level will increase by one step. At the maximum (rabbit) level, the
performance levels will begin at the lowest (turtle) level again.
Fcn.
No.
Minimum
Parameter
Maximum Parameter
MODE 1
48
Controlled Acceleration
60
5.0 sec
Fcn. No. 52
255
49
FW Pick–Up Current
N/A
N/A
0
N/A
50
Speed Limit 1
120
64%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
40
3.5 sec
Fcn. No. 56
Fcn. No. 48
53
FW Pick–Up Current
N/A
None
0
N/A
54
Speed Limit 1
85
80%
Fcn. No. 58
Fcn. No. 50
55
Not Used
MODE 3
17
Type ZY [9–inch Motor (Continued)]
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
56
Controlled Acceleration
30
2.6 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick–Up Current
N/A
0
N/A
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
MODE 4
60
Controlled Acceleration
20
1.8 sec
8
Fcn. No. 56
61
FW Pick–Up Current
N/A
0
N/A
62
Speed Limit 1
0
None
0
Fcn. No. 58
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter
(thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter
(tens/units)
Read Only
Secure Auxiliary Hourmeter
(thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by
user
Lift truck number assigned by
user
18
TABLE 6. EV–100ZX Parameters –All Lift Trucks (36 to 48 volts)
(Hydraulic Pump Card Type ZP)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
1
Stored Statue Code
0
1
—
0
1
/255
—
1
Any number other than “zero” can be read as a possible fault.
2
Internal Resistance
Compensation Start
10
65 amp.
0/255
3
Controlled Acceleration
50
1.04 sec
25/150
0.52 sec/3.1 sec
4
Current Limit (C/L)
255
max. amp
0/255
max. amperes
5
Not Used
6
Not Used
7
Controlled Acceleration
Compensation
15
8
Not Used
9
Not Used
10
Not Used
11
Speed Limit 1
35
13 volts
30/70
11 to 26 volts
12
Speed Limit 2
55
21 volts
30/70
11 to 26 volts
13
Speed Limit 3
255
Maximum
volts
30/255
11 to maximum volts
14
Speed Limit 4
255
Maximum
volts
30/255
11 to maximum volts
15
Not Used
16
Internal Resistance
Compensation
10
2.28 volts
17
Card Type Selection
with BDI Low Function
63 High Current Limit with lockout function
65 High Current Limit with lockout function
71 High Current Limit with lockout function
17
Card Type Selection
without BDI Function
45 High Current Limit without lockout function
50 High Current Limit without lockout function
53 High Current Limit without lockout function
18
Not Used
19
Not Used
20
Not Used
21
Not Used
22
Not Used
23
Not Used
24
Not Used
19
Type ZP (36 to 48 volts)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
25
Monitor Register
0
—
None
(Temporary storage
register)
26
Monitor Register
0
(Temporary storage
register)
27
Not Used
28
Fault Count Pointer
(Must be reset to zero to clear
Status Codes)
—
—
None
(Temporary storage register
that points to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0–99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
Function Numbers 31 through 47 can be read and cleared with a Hand Set. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can only be
reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62
enable the lift truck to be set to four performance levels by the
operator. (If the customer does not want this function available to the operator, a service person can
set all four levels to the same setting.) Each time the operator pushes the button on the instrument
panel, the performance level will increase by one step. At the maximum (rabbit) level, the
performance levels will begin at the lowest (turtle) level again.
Fcn.
No.
Minimum
Parameter
Maximum Parameter
MODE 1
48
Controlled Acceleration
120
2.5 sec
25
(0.52 sec)
150 (3.1 sec)
49
Speed Limit 2
35
13 volts
30 (11 volts)
70 (26 volts)
50
Speed Limit 3
84
30 volts
30 (11 volts)
255 (Maximum volts)
51
Not Used
MODE 2
52
Controlled Acceleration
80
1.7 sec
25
(0.52 sec)
150 (3.1 sec)
53
Speed Limit 2
48
18 volts
30 (11 volts)
70 (26 volts)
54
Speed Limit 3
96
36 volts
30 (11 volts)
255 (Maximum volts)
55
Not Used
MODE 3
56
Controlled Acceleration
50
1.04 sec
25
(0.52 sec)
150 (3.1 sec)
57
Speed Limit 2
61
23 volts
30 (11 volts)
70 (26 volts)
58
Speed Limit 3
255
Maximum
volts
30 (11 volts)
255 (Maximum volts)
59
Not Used
20
Type ZP (36 to 48 volts)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
MODE 4
60
Controlled Acceleration
25
25
(0.52 sec)
150 (3.1 sec)
61
Speed Limit 2
70
26 volts
30 (11 volts)
70 (26 volts)
62
Speed Limit 3
255
Maximum
volts
30 (11 volts)
255 (Maximum volts)
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter
(thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter
(tens/units)
Read Only
Secure Auxiliary Hourmeter
(thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by
user
Lift truck number assigned by
user
21
TABLE 7. EV–100ZX Parameters –All Lift Trucks (72 to 80 volts)
(Hydraulic Pump Card Type ZP)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
1
Stored Statue Code
0
1
—
0
1
/255
—
1
Any number other than “zero” can be read as a possible fault.
2
Internal Resistance
Compensation Start
10
65 amp.
0/255
3
Controlled Acceleration
50
1.04 sec
25/150
0.52 sec/3.1 sec
4
Current Limit (C/L)
255
max. amp
0/255
max. amperes
5
Not Used
6
Not Used
7
Controlled Acceleration
Compensation
15
8
Not Used
9
Not Used
10
Not Used
11
Speed Limit 1
70
26 volts
60/106
22 to 40 volts
12
Speed Limit 2
80
30 volts
60/106
22 to 40 volts
13
Speed Limit 3
255
Maximum
volts
60/255
22 to maximum volts
14
Speed Limit 4
255
Maximum
volts
60/255
22 to maximum volts
15
Not Used
16
Internal Resistance
Compensation
10
2.28 volts
17
Card Type Selection
with BDI Low Function
54 High Current Limit with lockout function
57 High Current Limit with lockout function
62 High Current Limit with lockout function
17
Card Type Selection
without BDI Function
36 High Current Limit without lockout function
40 High Current Limit without lockout function
44 High Current Limit without lockout function
18
Not Used
19
Not Used
20
Not Used
21
Not Used
22
Not Used
23
Not Used
24
Not Used
22
Type ZP (72 to 80 volts)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
25
Monitor Register
0
—
None
(Temporary storage
register)
26
Monitor Register
0
(Temporary storage
register)
27
Not Used
28
Fault Count Pointer
(Must be reset to zero to clear
Status Codes)
—
—
None
(Temporary storage register
that points to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0–99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
Function Numbers 31 through 47 can be read and cleared with a Hand Set. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can only be
reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62
enable the lift truck to be set to four performance levels by the
operator. (If the customer does not want this function available to the operator, a service person can
set all four levels to the same setting.) Each time the operator pushes the button on the instrument
panel, the performance level will increase by one step. At the maximum (rabbit) level, the
performance levels will begin at the lowest (turtle) level again.
Fcn.
No.
Minimum
Parameter
Maximum Parameter
MODE 1
48
Controlled Acceleration
120
2.5 sec
25
(0.52 sec)
150 (3.1 sec)
49
Speed Limit 2
66
25 volts
60 (22 volts)
106 (40 volts)
50
Speed Limit 3
133
50 volts
70 (26 volts)
255 (Maximum volts)
51
Not Used
MODE 2
52
Controlled Acceleration
80
1.7 sec
25
(0.52 sec)
150 (3.1 sec)
53
Speed Limit 2
80
30 volts
60 (22 volts)
106 (40 volts)
54
Speed Limit 3
160
60 volts
70 (26 volts)
255 (Maximum volts)
55
Not Used
MODE 3
56
Controlled Acceleration
50
1.04 sec
25
(0.52 sec)
150 (3.1 sec)
57
Speed Limit 2
101
38 volts
60 (22 volts)
106 (40 volts)
58
Speed Limit 3
255
Maximum
volts
70 (26 volts)
255 (Maximum volts)
59
Not Used
23
Type ZP (72 to 80 volts)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value (Min/Max)
MODE 4
60
Controlled Acceleration
25
25
(0.52 sec)
150 (3.1 sec)
61
Speed Limit 2
70
26 volts
60 (22 volts)
106 (40 volts)
62
Speed Limit 3
255
Maximum
volts
70 (26 volts)
255 (Maximum volts)
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter
(thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter
(tens/units)
Read Only
Secure Auxiliary Hourmeter
(thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by
user
Lift truck number assigned by
user