We reserve the right to make changes in design or add improvements without incurring the obligation to make such changes in equipment
previously manufactured.
TO:
ALL HYSTER INDUSTRIAL TRUCK DEALER PRINCIPALS, SERVICE MANAGERS
AND PARTS MANAGERS
Subject : EOAS (End Of Aisle Stop) System Operation, Magnet Installation and Sensor
Adjustment
EOAS (End Of Aisle Stop) System Operation
Cont …
PARTS - SERVICE
GRAM
FF00062
March 12, 1999
V30/35/40XMU
FF00062
Page 2
Cont …
FF00062
Page 3
Cont …
FF00062
Page 4
Magnet Installation
Referring to Figure A, The magnets are to be placed at the entrance/exit of every rack aisle. Magnet position is critical,
dimensions given on drawing have to be followed for proper operation of the system.
The center of the Magnet is to be 6000mm into the aisle and 162.5mm from the centerline of the aisle.
Figure A
Cont …
FF00062
Page 5
Magnet Sensor Placement/Adjustment on the VNA Unit
Referring to Figure B and C, The magnet sensor bracket centerline is to be mounted 162.5mm from the centerline of the VNA
unit (this will put the magnet sensor directly over the center of the magnet in the floor when the truck is fully in the aisle).
Figure C shows the correct distance from the floor the Magnet Sensor is to be mounted (this is a critical adjustment that allow
+/- 1mm deviation). If the Magnet Sensor is to low or high , it will not properly sense the magnet and thus not activate.
Figure B
Figure C