background image

66

T H E   A W A X   M O D U L E S

T H E   A W A X   M O D U L E S

background image

67

M U L T I - F U N C T I O N   M O D U L E S

M U L T I - F U N C T I O N   M O D U L E S



Low consumption inputs 



Control of switches with Acotomâ process



Control of mechanical safety systems

(grip switch, foot switch...)



Dip switch 

to choose reset mode

(automatic/manual)



DLC 

system



Dual area control (Awax27XXL)



Power supply 24Vac/dc



22,5 mm or 45 mm housing 



Plug-in terminals

DIMENSIONS

SAFETY CATEGORY

AWAX26XXL :

category 4 according to EN 954-1

AWAX27XXL :

category 4 according to EN 954-1

EN 292, EN 418, EN 1088, EN 60204-1

ADVICE

These safety modules are able to control up to 30
switches when there is an external power supply.

AWAX 26 XXL

13

23

33

41

14

24

34

42

A2

A1

C

V

T11T21T22 T12

SELF CONTROL

DEVICE

24Vacdc

K1

K2

VALIDATION

K1

K2

K3

K3

DIP-SWITCH ON 'N'

AWAX 26XXL AND AWAX 27XXL

AWAX 26XXL AND AWAX 27XXL

22,5

99

111

WIRING DIAGRAM

AWAX 27 XXL

13

23

33

41

14

24

34

42

A2

A1

T33

T34

SELF-CONTROL

DEVICE 2

T11 T21T22 T12

CONTROL AREA 1

43

53

63

81

44

54

64

82

T63

T64

T41 T51T52 T42

SELF CONTROL 

DEVICE 2

(A1/A2=24Vacdc +10%/-15%)

CONTROL AREA 2

K1

K2

K1

K2

K3

K3

K4

K5

K6

K4

K5

K6

AREA 1:DIP-SWITCH ON 'N'

AREA 2:DIP-SWITCH ON 'SR'

VALIDATION

45

99

111

8A/250V

ac

8A/50Vdc

CAT. 4

POLYV

ALENT

PLUG-IN

TERMINALS

DLC

SYSTEM

cat.4

cat.4

UP TO

 8

LINES

A

W

AX 26XXL

A

W

AX 27XXL

background image

68

AWAX 45XXL2

AWAX 45XXL2

M U L T I - F U N C T I O N   M O D U L E  

M U L T I - F U N C T I O N   M O D U L E  

W I T H   8 5 / 2 6 5 V   P O W E R   S U P P L Y  

W I T H   8 5 / 2 6 5 V   P O W E R   S U P P L Y  



Low consumption input 



Control of switches with  Acotom process



Control of mechanical switches 



DLC 

system



Plug-in terminals 



Dip switch 

to choose the reset mode

(automatic/manual)



85~265Vac power supply 



67.5 mm housing 

DIMENSIONS

SAFETY CATEGORY

AWAX45XXL2 :

category 4 according to  EN 954-1

EN 292, EN 418, EN 1088, EN 60204-1

ADVICE

This module can control up to 30 safety switches
with an external supply.

AWAX 45 XXL2

13

23
41

14

24
42

A2

SELF CONTROL

DEVICE

33

34

X1
X2

V1

V2

A1

T11T21T22 T12

DEVICE TO BE

CONTROLLED

K1

K2

K1

VALIDATION

K2

WIRING DIAGRAM

67,5

99

111

8A/250V

ac

8A/50Vdc

CAT. 4

MULTI-

FUNCTION

PLUG-IN

TERMINALS

DLC

SYSTEM

cat.4