Analysis of shear wall structures of variable thickness using continuous connection method

background image

CMM-2005 Computer Methods in Mechanics

June 21-24, 2005, Częstochowa, Poland

Analysis of shear wall structures of variable thickness using continuous connection method

Jacek Wdowicki and Elżbieta Wdowicka

Institute of Structural Engineering, Poznań University of Technology

Piotrowo 5, 60-965 Poznań

e-mail:

jacek.wdowicki@put.poznan.pl

Abstract

The paper presents the analysis of shear wall structures of variable thickness using a variant of the continuum method. In the

continuous approach the horizontal connecting beams, floor slabs and vertical joints are substituted by continuous connections. The
differential equation systems for shear wall structure segments of constant cross-section are uncoupled by orthogonal eigenvectors.

The boundary conditions for the whole structure yield the system of linear equations for the determination of all constants of

integration. The results obtained by means of this method show good agreement with those available in literature.

Keywords: shear wall structures, variable thickness, continuous connection method, tall buildings

1. Introduction

In the construction of multistorey reinforced concrete

buildings, shear wall structures are commonly used for resisting

lateral loads due to wind and seismic effects. Two methods

appear to be particularly suitable for the analysis of this type of

structure, namely, the continuum method [7], [17], [20], [19],

[1] and the finite strip method [12], [3]. The continuum method

has proved itself to be extremely practical in structural analysis

and design of tall buildings [10].

It is quite common that a shear wall may have different

thickness along the height of a building. The upper portion of

the wall is subjected to much lower stress than the portion near

the support. Hence, several reductions of the thickness of the

wall, as it goes up, is a common design practice [2]. The

application of the continuum method to the analysis of coupled

shear walls with abrupt changes in the cross-section has been

considered in Ref. [16], [4], [5], [15], [14] with the use of the

analytical method of solving differential equations. In Ref. [11],

[10] the finite difference method has been used. Methods
proposed in Ref. [6], [18] are based on a transfer matrix

technique. In Ref. [9] the iterative technique, based on a

combination of the finite strip method and the continuum

method, has been presented. In Ref. [8] a macro-element for the

analysis of coupled shear wall systems has been introduced. Its

formulation is based on the classical continuum method. The

purpose of the paper is to present the effective algorithm of the

analysis of shear wall structures of variable thickness using the
continuous connection method.

2. Governing differential equations

Equation formulations for a three-dimensional continuous

model of the shear wall structure with the constant cross-section

have been given in Ref. [20]. A structure, which changes its

thickness along the height, can be divided into n

h

segments,

each one having the constant cross-section. For k-th segment

the differential equations can be stated as follows:

),

(

)

(

)

(

,

(

)

(

)

(

)

(

)

(

)

(

1

z

f

z

N

z

N

h

h

z

k

k

N

k

k

N

k

k

k

=

′′

>

A

B

(1)

where B

(k)

is n

w

× n

w

diagonal matrix, containing

continuous connection flexibilities, A

(k)

is n

w

× n

w

symmetric,

positive definite matrix, dependent on a structure, n

w

is the

number of continuous connections which substitute connecting

beam bands and vertical joints, N

N(k)

(z) is a vector containing

unknown functions of the shear force intensity in continuous

connections and f

(k)

(z) is a vector formed on the basis of given

loads for the k-th segment of shear wall structure.

The boundary conditions have the following form [7], [15],

[18], [20]:

,

0

)

(

),

(

)

(

),

(

)

(

,

)

0

(

)

(

)

1

(

)

(

)

1

(

1

)

(

)

1

(

)

(

,

0

1

)

1

(

=

=

=

=

=

+

+

+

H

N

h

N

h

N

h

N

h

N

z

w

w

N

h

n

N

k

k

N

k

k

N

k

k

N

k

k

k

k

N

T

E

N

B

B

S

B

(2)

where S

E

is n

e

× n

w

boolean matrix, related to interaction

between shear walls and continuous connections, z

0

is the vector

containing given settlements of shear walls, n

e

is the number of

shear walls, h

k

is the ordinate of k-th change of the cross-section

and H is the structure height.

After determination of unknown functions of shear force

intensity in continuous connections it is possible to obtain the

function of horizontal displacements of the structure as well as

its derivatives using the following equations:

),

(

)

(

)

(

,

(

)

(

)

(

)

(

)

(

''

'

)

(

1

z

N

z

T

z

V

h

h

z

k

N

k

N

k

K

k

T

k

k

k

V

V

=

>

(3)

where k is the index of a segment of the constant cross

section, V(z) is a vector containing the functions of horizontal

displacements of the structure, measured in the global ordinate

system 0XYZ and T

K

(z) is the vector of the functions of shear

forces and a torque due to the action of lateral loads.

Matrices V

T

, V

N

appearing in the above relation are

described by the following formulae:

,

1

,

)

(

N

T

T

N

Z

T

T

C

L

V

V

L

K

L

V

=

=

background image

CMM-2005 Computer Methods in Mechanics

June 21-24, 2005, Częstochowa, Poland

2

where L is 3n

e

× 3 matrix of coordinates transformation

from the global coordinate system 0XYZ to the local systems,

i.e. systems of principal axes of shear walls, K

Z

is 3n

e

× 3n

e

matrix containing transverse stiffness of shear walls and C

N

is

3n

e

× n

w

matrix containing the coordinates of the points of

contraflexure in connections in the local systems of axes.

The boundary conditions have the following form:

.

0

)

(

,

0

)

0

(

,

0

)

0

(

''

)

(

'

)

1

(

)

1

(

=

=

=

H

V

V

V

h

n

(4)

Besides, at the stations, where the cross sections of the walls

change, the following compatibility conditions can be stated.

From the geometric compatibility consideration we have:

).

(

)

(

),

(

)

(

'

)

1

(

'

)

(

)

1

(

)

(

k

k

k

k

k

k

k

k

h

V

h

V

h

V

h

V

+

+

=

=

(5)

From equilibrium consideration the following condition is

obtained:

),

(

)

(

)

1

(

)

(

k

k

E

k

k

E

h

m

h

m

+

=

(6)

where m

E

(z) is a vector of bending moments in shear walls,

described by the relation:

).

(

)

(

''

z

V

z

m

Z

E

L

K

=

(7)

Substituting (7) in Eqn (6) and next premultiplying by

V

T(k)

L

T

(k)

, the following condition is obtained:

)

(

)

(

''

)

1

(

)

,

1

(

''

)

(

k

k

k

k

V

k

k

h

V

h

V

+

+

=

S

(8)

where:

.

)

1

(

)

1

(

)

(

)

(

)

,

1

(

+

+

+

=

k

k

Z

T

k

k

T

k

k

V

L

K

L

V

S

3. Method of solution

In the proposed method the algorithm of solving the

differential equation system, used for structures of constant

cross-section [20], has been extended so as to enable us to take

into account structures of the variable section.

In order to uncouple differential equation systems auxiliary

functions

g

(k)

(z)

satisfying these relations have been introduced:

),

(

)

(

)

(

)

(

2

/

1

)

(

)

(

z

g

z

N

k

k

k

k

N

Y

B

=

(9)

where Y

(k)

is matrix columns which are eigenvectors of the

symmetric matrix P

(k)

=

B

(k)

-1/2

A

(k)

B

(k)

1/2

.

Consequently, n

w

second-order differential equations have

been obtained in the following form:

)

(

,

)

(

)

(

,

(

)

(

2

/

1

)

(

)

(

)

(

)

(

)

(

)

(

)

(

1

z

f

Y

F

F

z

g

z

g

h

h

z

k

k

T

k

i

k

Bi

k

Bi

k

i

k

i

k

i

k

k

=

=

′′

>

B

λ

(10)


where

)

(k

i

λ

is i-th eigenvalue of matrix

)

(k

P

, and

)

(k

i

Y

is eigenvector corresponding to the i-th eigenvalue. The
eigenvalues and eigenvectors of symmetric matrix

)

(k

P

are

computed by a set of procedures realizing the Householder’s

tridiagonalization and the QL algorithm, which have been

inserted in Ref. [22] and later written in Pascal.

The form of solutions from Eqn (10) is as follows:

),

(

)

(

)

(

)

(

2

)

(

1

)

(

)

(

)

(

z

W

r

e

C

e

C

z

g

S

k

Si

z

k

i

z

k

i

k

i

k

i

k

i

+

+

=

λ

λ

(11)

where C

1i(k)

,C

2i(k)

are integration constants, r

Si(k)

are

particular solution coefficients, calculated by indeterminate

coefficient method and W

S

(z) = col (z

0

, z

1

, ... ,z

s-1

).

Introducing Eqn (11) into the relation (9) and later

considering boundary conditions (2) we will obtain the system

of 2 n

h

n

w

equations for the determination of all constants of

integration in the form:

,

S

W

P

C

=

R

(12)

where R

W

is unsymmetric matrix, C is a vector of

integration constants and P

S

is a vector dependent on loadings.

The solutions are computed by the procedures based on the LU

factorization, where L is lower-triangular and U is upper-

triangular, taken from Ref. [22].

The next step of computations is determining functions of

horizontal displacements of the structure and their derivatives

necessary to calculate internal forces and stresses.

The integration of functions

)

(

'''

z

V

taking into

consideration boundary condition

0

)

(

''

)

(

=

H

V

h

n

and the

compatibility condition (8) yields the following expressions:

,

)

(

)

(

,

(

'''

)

(

''

)

(

1

dt

t

V

z

V

H

h

z

z

H

n

n

n

h

h

h

=

>

(13)

+

+

+

=

>

z

h

k

k

k

k

V

k

k

k

k

k

h

V

dt

t

V

z

V

h

h

z

).

(

)

(

)

(

,

(

''

)

1

(

)

,

1

(

'''

)

(

''

)

(

1

S

Next, integrating the above functions with regard to

boundary conditions V

(1)

(0)

= 0, V

(1)

’(0) = 0 and compatibility

conditions (5), the following is obtained:

>

k

k

h

h

z

,

(

1

,

)

(

)

(

)

(

1

'

)

1

(

''

)

(

'

)

(

1

+

=

k

k

z

h

k

k

h

V

dt

t

V

z

V

k

(14)

+

=

z

h

k

k

k

k

k

h

V

dt

t

V

z

V

1

,

)

(

)

(

)

(

1

)

1

(

'

)

(

)

(


where: k = 1,…,n

h

, h

0

= 0.

Integration is realized numerically.

On the basis of the presented algorithm the software

included in the system for the analysis of shear wall tall

buildings [20], [21] in the Delphi environment has been

implemented.

background image

CMM-2005 Computer Methods in Mechanics

June 21-24, 2005, Częstochowa, Poland

3

4. Numerical

examples

In the course of system testing there has been a good

agreement of our results and those presented in Ref. [16], [14],

[15], [6], [12], [3], [8] and obtained from tests on Araldite

models [6]. To illustrate the correctness of algorithm

realization, three examples of coupled shear walls of variable

thickness have been chosen.

4.1. Example 1: Symmetrical shear wall with step change

in thickness and uniform continuous connection

The 22-storey symmetrical coupled shear wall with a step

change in thickness, previously studied by Rosman [15], is

analysed. The storey height is 2.69 m, depth of walls is 6.50 m

and span of continuous connections is 1.65 m. The shear wall

thickness at the lower 10 storeys is 0.407 m and in the upper

12 storeys is 0.288 m. The floor slabs of depth 0.21 m and

width 6.50 m are considered as continuous connections. The
modulus of elasticity of concrete is taken to be

E = 2.1 10

5

kG/cm

2

, and the shear modulus G = 3/7 E. The wall

is subjected to lateral load due to wind action. In Fig.1 there are

diagrams of horizontal displacements and shear force intensity

in continuous connection. The maximum displacement and

maximum shear force intensity given in Ref. [15] are 0.0132 m

and 5346 kG/m, respectively and it shows a good agreement.

4.2. Example 2: Asymmetrical shear wall with step change

in thickness

In this example, analysed previously in Ref. [2], [3], the

connecting beam as well as walls have step change in thickness.

The 21-storey asymmetrical coupled shear wall consisted of two

segments of different thickness, with a constant storey height of

1.0. All dimensions are given in inches. The shear wall

thickness at the lower 11 storeys is 0.625 and in the upper 10

storeys is 0.375. The depth of the left and right wall is 3.0 and
2.5, respectively. The depth of connecting beams is 0.25. The

effective span length of a beam is taken as 1.5 + 0.25 = 1.75.

The adjustment to the span length of the spandrel beam is to

allow for the fact that the rigid-end condition could not possibly

occur immediately at the junction of the wall and the beam [13].

The shear wall is assumed to be made of isotropic material

having Young’s modulus E of 463 000 lb/sq.in. and Poisson’s

ratio of 0.0. The shear wall is subjected to a unit horizontal

uniformly distributed load at the left side.

In Fig. 2 there is a plan of the shear wall and normal stress

distribution across section at z = 3.375. The obtained diagrams

of horizontal deflection and shear force intensity in continuous

connection are shown in Fig. 3. The computations correlated

well with the results obtained by the finite element method and

the finite strip method [2], [3].

4.3. Example 3: Asymmetrical shear wall consisted of

three segments of different thickness.

Fig. 4 shows the plan of 31-storey asymmetrical shear wall

with two bands of openings created by the extension of

Example 2. In the modified structure the wall of depth 2.5,

connected by the same spandrel beams as in Example 2, has

been inserted on the right side. Furthermore, the whole structure

has been heighten by 10-storey segment of thickness 0.25. The

properties of material and the loads are taken to be the same as
in Example 2. Fig. 4 shows the normal stress distribution at the

base of the structure. In Fig. 5 there are diagrams of horizontal

displacements and shear force intensity in two continuous

connections. The short time of computations for this example

confirms the efficiency of the proposed algorithm.

5. Final

remarks

The paper presents the algorithm for the analysis of shear

wall structures of variable thickness, using a variant of the

continuous connection method. The conducted tests have

confirmed correctness of the algorithm realization. The

proposed algorithm is effective and can be useful for a design

analysis of tall buildings.

Acknowledgement Financial support by Poznan University

of Technology grant DS-11-650/05 is kindly acknowledged.


References

[1] Aksogan, O., Arslan, H.M. and Choo, B.S., Forced

vibration analysis of stiffened coupled shear walls using

continuous connection method, Engineering Structures,
25, pp. 499-506, 2003.

[2] Chan, H.C. and Cheung, Y.K., Analysis of shear wall using

higher order finite elements, Building and Environment, 14,

pp. 217-224,1979.

[3] Cheung, Y.K., Au, F.T.K. and Zheng, D.Y., Analysis of

deep beams and shear walls by finite strip method with C0

continuous displacement functions, Thin-Walled Structures,

32, pp. 289-303, 1998.

[4] Coull, A. and Puri, R.D., Analysis of coupled shear walls of

variable thickness, Build. Sci., 2, pp. 181-188, 1967.

[5] Coull, A. and Puri, R.D.: Analysis of coupled shear walls of

variable cross-section, Build. Sci., 2, pp. 313-320, 1968.

[6] Coull, A., Puri, R.D. and Tottenham, H., Numerical elastic

analysis of coupled shear walls, Proceedings of the

Institution of Civil Engineers, Part 2, 55, pp. 109-128,

1973.

[7] Glück, J. and Gellert, M., Three dimensional lateral load

analysis of multistorey structures, Publications IABSE,
(Mémoires Abhandlungen Publications)
, 32-I, pp.77-90,

1972.

[8] Ha, K.H. and Tan, T.M.H., An efficient analysis of

continuum shear wall models, Canadian Journ. of Civ.

Engineering, 26, pp. 425-433, 1999.

[9] Ho, D. and Liu, C.H., Shear-wall and shear-core assemblies

with variable cross-section, Proceedings of the Institution of

Civil Engineers, 81, pp.433-446, 1986.

[10] Liang, Q., Recent development of 3-dimensional analysis

of tall building structures by continuum method, Recent

Developments and Future Trends of Computational

Mechanics in Structural Engineering, Proceedings of

Sino-US Joint Symposium, Beijing, China, Cheng, F.Y. and

Zizhi, F. Eds, Elsevier, pp. 246-259, 1992.

[11] Liauw, T.-C. and Luk, W.K., Torsion of core walls of

nonuniform section, Journal of the Structural Division,

Proc. ASCE, 106, pp.1921-1931, 1980.

[12] Lis, Z., Calculations of tall buildings braces with stepped

characteristics, Archiwum Inżynierii Lądowej, 23,

pp. 527-534, 1977 (in Polish).

[13] Michael, D., The effect of local deformations on the

elastic interaction of cross walls coupled by beams, in: Tall

Buildings, Pergamon Press, 1967, 253-270.

[14] Pisanty, A. and Traum, E.E., Simplified analysis of

coupled shear walls of variable cross-section, Building

Science, 5, pp.11-20, 1970.

[15] Rosman, R., Analysis of coupled shear walls, Arkady,

Warszawa 1971 (in Polish).

background image

CMM-2005 Computer Methods in Mechanics

June 21-24, 2005, Częstochowa, Poland

4

[16] Traum, E.E., Multistorey pierced shear walls of variable

cross-section, in: Tall Buildings, Pergamon Press, Oxford,

London, pp. 181-206, 1967.

[17] Tso, W.K. and Biswas, J.K., General analysis of nonplanar

coupled shear walls, J. of Struct. Div., Proc. ASCE, 99,

pp. 365-380, 1973.

[18] Tso, W.K. and Chan, P.C.K., Static analysis of stepped

coupled walls by transfer matrix method, Building Science,

8, pp. 167-177, 1973.

[19] Wdowicka, E.M., Wdowicki, J.A. and Błaszczyński, T.Z.:

Seismic analysis of the "South Gate" tall building according

to Eurocode 8, The Structural Design of Tall and Special

Buildings, 14, pp. 59-67, 2005.

[20] Wdowicki, J. and Wdowicka, E., System of programs for

analysis of three-dimensional shear wall structures, The

Structural Design of Tall Buildings, 2, pp. 295- 305, 1993.

[21] Wdowicki J.A., Wdowicka E.M. and Tomaszewski A.M.:

Integrated System for multistorey buildings – use of

software engineering rules, 2

nd

European Conference on

Computational Mechanics: Solids, Structures and Coupled

Problems in Engineering, Cracow, Poland, Abstracts,

Vol. 1, 408-409, full version on CD-ROM, minisymposium
10, pp. 1-20, 2001.

[22] Wilkinson J.H. and Reinsch C.: Linear Algebra, Handbook

for Automatic Computation, vol. II, Springer-Verlag, Berlin,

Heidelberg, New York, 1971.



Figure 1: Example 1 - Horizontal displacements and shear force intensity function in continuous connection

background image

CMM-2005 Computer Methods in Mechanics

June 21-24, 2005, Częstochowa, Poland

5

Figure 2: Example 2 - Plan of shear wall and normal stresses at z = 3.375

Figure 3: Example 2 - Horizontal displacements and shear force intensity function in continuous connection

background image

CMM-2005 Computer Methods in Mechanics

June 21-24, 2005, Częstochowa, Poland

6

Figure 4: Example 3 - Plan and normal stresses at the base of shear wall structure

Figure 5: Example 3 - Horizontal displacements and shear force intensity functions in two continuous connections


Wyszukiwarka

Podobne podstrony:
Analysis of spatial shear wall structures of variable cross section
„SAMB” Computer system of static analysis of shear wall structures in tall buildings
SEISMIC ANALYSIS OF THE SHEAR WALL DOMINANT BUILDING USING CONTINUOUS-DISCRETE APPROACH
Butterworth Finite element analysis of Structural Steelwork Beam to Column Bolted Connections (2)
GL Syntax The analysis of sentence structure
Analysis of Reinforced Concrete Structures Using ANSYS Nonlinear Concrete Model
GL Morphology The analysis of word structure
Butterworth Finite element analysis of Structural Steelwork Beam to Column Bolted Connections (2)
An%20Analysis%20of%20the%20Data%20Obtained%20from%20Ventilat
[2001] State of the Art of Variable Speed Wind turbines
A Contrastive Analysis of Engli Nieznany (3)
Analysis of soil fertility and its anomalies using an objective model
Pancharatnam A Study on the Computer Aided Acoustic Analysis of an Auditorium (CATT)
Analysis of the Persian Gulf War

więcej podobnych podstron