1.0
INTERN AL LABORATORY SCOPE
2.0 SCOPE:
This procedurę is to define the Intemal Laboratory Scope
3.0 QUALITY PROCEDURĘ:
Heat Treat Laboratory Scope - Ref. Clause 7.6J.1 Technical Capability:
Feature measured Crystal grain size Fiber flow Micrastructure |
Rance 50,100,200,400 &1000X magnilication |
Eauioment Olympus PME-3 Metal lo grap h |
Surface hardness |
HRB & HRC scales |
Mitutoyo ARK-600 |
Core hardness |
convert to all scales |
Mitutoyo ATK-F2000 Macro-hardness testers |
Case Depth |
Hvickers |
Leco 300AT |
Indirect surface hardness |
convert to all scales |
Futurę Tech FM700 Micro-hardness testers |
Ali testing equipment and performed tests are in compliance with applicable ASTM stan dar ds. Reference standards are as follows:
• ASTM E-112 Determine Grain Size
• ASTM E-407 Microetching Metals and Alloys
• ASTM E3-01 Preparation of Metal k) grap hic Specimens
• ASTM E92-82 Vickers Hardness of Metallic Materials
• ASTM El40-02 Conversion Tables
• ASTM E2014-99 Metallographic Laboratory Safety
Calibrations and Master Yerification:
Annual calibrations and daily master verifications are performed as specified in:
• ASTM E-18 for Rockwell testers
• ASTM E-384 for microvickers testers
• ASTM Er 1951 for microscopes
Ali hardness measuring devices are verified daily by the use of N.I.S.T. traceable standard blocks. Daily verifications are logged in Master Verification Log Book in Heat Treat department.
M.S.C. Heat Treat laboratory uses Leco Corporation for annual calibration of all optical measuring devices.
Leco optical service calibrations are accredited to ISO 17025 by A2LA.Calibration records and laboratory scope for e.\temal bb are kept on file in the Gage Control section of Quality Control.
Test Methods and Specifications:
All characteristics tested have guidelines and specifications provided in tlie customer dra win gs located in tlie Quality Control area and listed on Operator Process Instructions.
QC SP 008 INTERNAL LABORATORY SCOPE |
PAGE 1 OF 2 |
PREPARED BY : Jonathon Leach |
REVISION DATĘ : JAN.20.2003 |
APPROYED BY : Ralph SuLser |
RE\'ISION : 0 |
Musashi South Carolina - Procedurę
Notc: Printcd documcnts aro not controllcd copics-chcck master Computer filcs for latcst rcvision