3582374786

3582374786



1.0


INTERN AL LABORATORY SCOPE

2.0    SCOPE:

This procedurę is to define the Intemal Laboratory Scope

3.0    QUALITY PROCEDURĘ:

Heat Treat Laboratory Scope - Ref. Clause 7.6J.1 Technical Capability:

Feature measured Crystal grain size Fiber flow Micrastructure

Rance

50,100,200,400 &1000X magnilication

Eauioment Olympus PME-3 Metal lo grap h

Surface hardness

HRB & HRC scales

Mitutoyo ARK-600

Core hardness

convert to all scales

Mitutoyo ATK-F2000 Macro-hardness testers

Case Depth

Hvickers

Leco 300AT

Indirect surface hardness

convert to all scales

Futurę Tech FM700 Micro-hardness testers

Ali testing equipment and performed tests are in compliance with applicable ASTM stan dar ds. Reference standards are as follows:

•    ASTM E-112 Determine Grain Size

•    ASTM E-407 Microetching Metals and Alloys

•    ASTM E3-01 Preparation of Metal k) grap hic Specimens

•    ASTM E92-82 Vickers Hardness of Metallic Materials

•    ASTM El40-02 Conversion Tables

•    ASTM E2014-99 Metallographic Laboratory Safety

Calibrations and Master Yerification:

Annual calibrations and daily master verifications are performed as specified in:

•    ASTM E-18 for Rockwell testers

•    ASTM E-384 for microvickers testers

•    ASTM Er 1951 for microscopes

Ali hardness measuring devices are verified daily by the use of N.I.S.T. traceable standard blocks. Daily verifications are logged in Master Verification Log Book in Heat Treat department.

M.S.C. Heat Treat laboratory uses Leco Corporation for annual calibration of all optical measuring devices.

Leco optical service calibrations are accredited to ISO 17025 by A2LA.Calibration records and laboratory scope for e.\temal bb are kept on file in the Gage Control section of Quality Control.

Test Methods and Specifications:

All characteristics tested have guidelines and specifications provided in tlie customer dra win gs located in tlie Quality Control area and listed on Operator Process Instructions.

QC SP 008 INTERNAL LABORATORY SCOPE

PAGE 1 OF 2

PREPARED BY : Jonathon Leach

REVISION DATĘ : JAN.20.2003

APPROYED BY : Ralph SuLser

RE\'ISION : 0

Musashi South Carolina - Procedurę

Notc: Printcd documcnts aro not controllcd copics-chcck master Computer filcs for latcst rcvision


Wyszukiwarka

Podobne podstrony:
LABORATORY OF THE INTER-DOMAIN ROUTING - BGP SECURITYAbstract The aim of this work is to analyse the
Effect Of Dividends On Stock Prices 18 The objective of this study is to analysis the relationship b
44 M. SIKORSKI ABSTRACT The aim of this paper is to review the most widely used techniąue for studie
carriage?ce may want to replace the stop once it gets too cut up. This hook is to preent the clamp f
Ciphering start procedurę This ciphering start procedurę is initiated from the MSC/VLR by sending th
•i •i • A-    * 4.    This procedurę is very cffecrive in
Library of Congress Cataioging-in-Publication Data A C.I.P. Catalogue record for this book is availa
MR293R19041 1 This operation is to be carried out on tha body jig bench. See sub-section 40 of
Disclaimer This document is to provide information and is for illustration purposes only. Accordingl
PROBLEMY PIELĘGNIARSTWA 2014, tom 22, zeszyt nr 3 Aim. The purpose of this study is to analyze opini
56 (167) capsule (1-30 pm). This capsule is responsible for the virulence of this fungus and explain
28 (209) 74 Cbapter 2 selected and the procedurę is repeated. In the first case, however, the b
That is in formal words, but for your information the effect is to introduce the Office of past pres

więcej podobnych podstron