209
RIKEN Accel. Próg. Rep. 24 (1990)
The radiation safety control system has work-
Table 1. Dose rates of neutron leakage radiation from a target point A in extended experimental vault E5 (see Figs. 1-a,b).
Measured point |
Dose rates (u Sv/h) |
Measured point |
Dose rates (m Sv/h) |
a |
0.56 |
S |
0.002 |
b |
0.34 |
h |
0.006 |
c |
0.033 |
• i |
125 |
d |
0.002 |
3 |
14 |
e |
0.010 |
k |
0.125 |
f |
1.80 |
Table 2. Dose rates of neutron leakage radiation from a
target point B in the beam distribution corridor. (see Figs.l- a,b,c.) A letter “A” stands for the neutron dose ratę meter of 2202D Studsvik No.83064; “B” for 2202D of Studsvik No.89006; “C” for 2202D of Studsvik No. 86032; and “D” for NSN1001 of Fuji electric. | |||
Measured point |
Doicclo r n ame |
Coun l rates (C/3rain) |
Dose rates (#Sv/h) |
( 1 ) |
11 |
0 |
0 |
( 2 ) |
A |
0 |
0 |
( 3 ) |
c; |
2 |
0. 03 |
( 4 ) |
c |
17 |
0. 22 |
( 5 ) |
c |
89 |
1.15 |
( 6 ) |
11 |
1 84 |
3. 1 0 |
( 7 ) |
A |
38 |
0.64 |
( 8 ) |
c: |
4 |
0. 05 |
( 9 ) |
11 |
2 |
0. 03 |
(10) |
11 |
0 |
0 |
(11) |
c; |
0 |
0 |
(12) |
n |
0 |
0 |
(13) |
c |
0 |
0 |
(14) |
11 |
0 |
0 |
(15) |
A |
0 |
0 |
(16) |
C |
3 |
0. 04 |
(17) |
O |
42 |
0. 54 |
(18) |
c |
6 |
0. 08 |
(19) |
c |
34 |
0. 44 |
(20) |
B |
9 |
0.15 |
(21) |
15 |
5 |
0. 08 |
(22) |
11 |
22 |
0. 37 |
(23) |
B |
1 1 0 |
1.85 |
(24) |
11 |
6 |
0. 1 0 |
(25) |
11 |
82 |
1. 38 |
(26) |
c: |
15 |
0. 1 9 |
(27) |
11 |
0 |
0 |
(28) |
B |
0 |
0 |
(29) |
1) |
— |
0. 002 |
(30) |
1) |
- |
0. 002 |
(31) |
I) |
— |
0. 020 |
(.32) |
1) |
— |
0.0 18 |
(33) |
1) |
— |
0. 029 |
(34) |
1) |
- |
0. 006 |
(35) |
n |
— |
0. 055 |
(36) |
D |
- |
0. 040 |
(37) |
1) |
- |
0. 029 |
(38) |
1) |
- |
0. 059 |
(39) |
1) |
— |
0. 0 30 |
(40) |
I) |
- |
0. 006 |
(c)
Fig. 1. Layout of RIKEN Ring Cyclotron facility as of 1990. a : Plan view of basement 2th floor; b : Plan view of basement lth floor; c : Plan view of first floor. Leakage radiation doses measuring points are denoted by alphabets and the number in the parentheses.