J H 032


J-H-32
PARTS-SERVICE
Sept. 20, 1989
All Models
GRAM
Subject: Factory Installed Accumulators
Ref: Greer Bladder Type
Field experience has shown that accumulators are often replaced when the accumulator will not hold a
charge. The cause is often misdiagnosed as a bladder leak when the leak is actually due to a valve
stem or valve stem core problem.
Before arbitrarily replacing the accumulator, be sure to check the valve stem and core for leakage
with a soap solution.
WARNING: If the valve stem core is leaking, do not replace it with a low pressure valve stem core
as used in automotive tires.
NOTE: Replacement parts can be purchased from any local supplier which sells Greer
Bladder Type accumulators.
1. Tank Valve (stem) - Greer P/N - 300096
2. Valve Stem Core - Greer P/N - 300510
We reserve the right to make changes in design or add improvements without incur-
ring the obligation to make such changes in equipment previously manufactured.