Mine Ventilation Society
Free State Region
‘Instope” Ventilation Control
Symposium
16 October 2002
Lodewyk Roux
Harmony Gold Mining Company Ltd
“Instope Ventilation Control” Symposium 16/10/2002
“Instope Ventilation Control” Symposium 16/10/2002
When working hard the human body produces heat at the rate of
240w/m²
This heat is then removed by - transferred to the ventilating air
For various wet bulb temperatures the actual velocity required will
vary
I.E.
29.0° Wet Bulb - Velocity = 0.3m/s
30.0° Wet Bulb - Velocity = 0.5m/s
31.0° Wet Bulb - Velocity = 0.9m/s
32.0° Wet Bulb - Velocity = 1.6m/s
32.5° Wet Bulb - Velocity = 2.6m/s
Î
Max allowable WB Temp
33.0° Wet Bulb - Velocity = 4.0m/s
SLIDE 1
“Instope Ventilation Control” Symposium 16/10/2002
“Instope Ventilation Control” Symposium 16/10/2002
Vent Seal
Quantity =20m³/s
Area =10
m²
Velocity =2.0m/s
SLIDE 6
“Instope Ventilation Control” Symposium 16/10/2002
“Instope Ventilation Control” Symposium 16/10/2002
Ventilation Curtain
Pack not sealed
Packs
Open Area at Packs cannot be ignored
SLIDE 8
“Instope Ventilation Control” Symposium 16/10/2002
“Instope Ventilation Control” Symposium 16/10/2002
Ventilation Curtain
Gaps in ventilation curtains
Open Area between ventilation control and hanging cannot be
ignored
SLIDE 9