Czujniki do systemow kontroli s ulotka id 129017

background image

Sensorregler

Differenzdruck- & Volumenstromregelung für die Klimatechnik

Sensor control system

Differential pressure & air volume control for air conditioning

Sensor mit Druck- oder Volumenstromanzeige und vollwertiger Regelfunktionalität in einem Gerät
Sensor with pressure gauge or volume flow display and complete control functionality included

Einfachste Installation, direkt an EC-Motor, Frequenzumrichter oder Regelgerät anschließbar
Easy installation, direct connection to EC motors, frequency inverters or other controllers

Direkte Montage an Klimakastengeräte, Dachventilatoren oder Lüftungsgeräte
Direct mounting on air handling units, roof fans or ventilation appliances

Lie

fer

ba

r M

ai 2

00

9

Av

aila

ble

M

ay

20

09

background image

©

b

y

Z

ie

hl

-A

be

gg

-

0

02

95

67

2

-

02

/2

00

9

-

K

&

E

-

T

ec

hn

is

ch

e

Ä

nd

er

un

ge

n

vo

rb

eh

al

te

n.

/

S

ub

je

ct

t

o

te

ch

ni

ca

l m

od

ifi

ca

tio

ns

.

Sensorregler

Sensor control system

Ziehl-Abegg AG
Heinz-Ziehl-Straße · 74653 Künzelsau · Germany
Tel. +49 (0) 7940 16-0 · Fax +49 (0) 7940 16-677
info@ziehl-abegg.de · www.ziehl-abegg.com

Differenzdruck- und Volumenstromregelung
für die Klimatechnik

Eigenschaften - Vorteile
• Der Sensorregler misst und zeigt den Differenz-

druck oder wahlweise den Volumenstrom in einem
Lüftungssystem

• Durch Eingabe des K-Faktors der Ventilator-

einlaufdüse wird der Volumenstrom berechnet

• Durch Eingabe des gewünschten Sollwert und des

Regelbereichs gibt der Sensorregler 0-10 V aus um
den Ventilator anzusteuern

• Wahlweise kann der Sensorregler als Regelgerät

oder als Sensor mit Anzeige betrieben werden

• Versorgung des Geräts aus dem angeschlossenen

Frequenzumrichter, EC-Ventilator oder sonstigem
Regelgerät mit 10 V DC

• Umschaltbare Druckbereiche innerhalb der drei

Ausführungen: 0-200 / 0-1000 / 0-6000 Pa

Anwendungsbeispiele

Differential pressure and air volume control
for air conditioning

Features - advantages
• Measurement and monitoring of the differential

pressure or air volume flow in a ventilation system

• Calculation of the air volume flow through input

of the inlet ring K factor

• Input of the desired set point and control range,

for the generation of a 0-10 V signal to activate
the fan

• Configurable operation as closed loop controller or

as sensor with display

• Power supply to controller via the connected

frequency inverter, EC controller or other
control unit with 10 V DC

• Configurable for three pressure ranges:

0-200 / 0-1000 / 0-6000 Pa

Application examples

- +

m

3

Volumenstromregelung in Klimakastengeräten
Air volume flow control in air handling units

Differenzdruckregelung bei Dachventilatoren
Differential pressure control with roof fans

DPa

Netz / mains

Netz / mains


Wyszukiwarka

Podobne podstrony:
wprowadzenie do systemu win i podst sieci
1 Wprowadzenie do psychologii pracy (14)id 10045 ppt
Odpowiedzi do testu 1 poziom podstawowy id 332449
Dostosuj zakład do przepisów prawa pracy Komentarz do ankiety kontrolnej bhp na budowie, 2005 cz3
MATERIALY DO WYKLADU CZ IV id Nieznany
Karta postaci do systemu Glebia Przestrzeni
6 - Znaczenie konformizmu w systemie kontroli spol. sms, zchomikowane, 35 000 edukacyjnych plikó
JAVASCRIPT Kod kodu testu z JavaScript do pracy kontrolnej
Amerykański i europejski system system kontroli konstytucyjności prawa
Kanicki Systemy Rozdzial 10 id Nieznany
Ekstrema warunkowe Zadanie do Rozwiazanie zadania domowego id
materialy metodyczne do i pracy kontrolnej
Niektóre prawne aspekty włamań do systemu komputerowego
AUDYT SYSTEMU KONTROLI WEWNĘTRZNEJ
Mssf Lista kontrolna 2011 id 310018
Kontrolki diodowe id 247015 Nieznany
o systemie oceny zgodnosci id 3 Nieznany
Czujniki stosowane w systemach automatyki, Studia
JAVASCRIPT Kod kodu testu z JavaScript do pracy kontrolnej

więcej podobnych podstron