affinity product brochure

background image

Affinity

®

NT

OxygeNATiON SySTem

Clearly the Choice

for

Consistent Performance

and

Reliable Results

background image

Indication: The oxygenator is indicated for

use in an extracorporeal circulation circuit to

oxygenate and remove carbon dioxide from

the blood and to cool and warm the blood

during cardiopulmonary bypass procedures

up to 6 hours in duration.

Smart Design

that

Sets the Standard

for Oxygenators

Consistent performance starts with an oxygenator
design that has set the standard for the industry.
The Affinity NT’s radial flow design and proprietary
fiber winding technique provide the reliable
results you desire in a constantly changing cardiac
surgery environment.

Continued optimization in the manufacturing
process contributes to the consistent performance
you have come to expect. With over 4 million
oxygenators produced on a single manufacturing
line, you—and your patients—can rest assured.
The goal of our precision manufacturing is to
minimize surprises for you in the operating room.

background image

Pre-membrane Access Port
• engineered to facilitate

easy prime

• Provides ability to measure

pre-membrane pressure

• Offers option for

hemoconcentrator access

Proprietary Graduated Fiber

Bundle Density Technology and

Radial Flow Design Provides:
• enhanced gas transfer
• Low pressure drop
• Short, uniform blood flow path
• Avoidance of areas of stasis

Exact Alignment of Potting Material
• Designed to prevent air from being trapped

above recirculation port for easy prime

Unique Radial Flow Design
• intended to eliminate performance

variation because fiber bundle

is not force fit into case

Metal Bellows Heat Exchanger
• Consistent performance with

minimal pressure drop

Affinity—the first oxygenator with a radial blood flow design and
use of computational flow dynamics to optimize the blood flow path.

Affinity—the only oxygenator with graduated fiber winding technique
for optimized bundle efficiency and manufacturing consistency.

background image

Versatile Cardiotomy Turret

• 3/8” and 1/4” filtered ports for priming ease
• multiple filtered luer ports
• Cardiotomy ports on rotating turret
• Rotating turret easily clears manifold

Simple Drop-in Holder

• Articulated design is

compatible with left-

and right-hand setup

Hollow Fiber Oxygenator
• Plasma resistant fiber intended for

greater resistance to plasma breakthrough

• Total visibility pre-membrane and

post-membrane for your priming confidence

Coatings
• Available with heparin

biocompatible surfaces

Optimum Operating Levels
• maximum capacity of 4000 ml for

maximum patient versatility

• Low minimum operating level of 200 ml
• Designed for excellent low-level visualization

with color-coded volume measurements

and low-level warning label

Excellent Air Handling Capabilities
• Separate venous and cardiotomy inlets
• Designed to prevent blood contact

with defoamer unless foam is present

• Final screen provides additional

barrier intended to remove air

and other emboli

background image

Totally

Clear Design

for

Unobstructed Visibility

of Blood, gas and Water Phases

Removable Sampling Manifold
• High-flow stopcocks and

color-coded sampling lines

Optimal Visibility Achieved
• Clear lid and the elimination of

“outer sock” design

• excellent visibility of venous inlet column

on the outside of the cardiotomy

Vacuum-Assisted Venous Drainage (VAVD)

Compatible
• A negative/positive pressure-relief valve is

built into the lid -150 mm Hg/0-5 mm Hg,

which features a special obturator valve cap

engineered to ensure valve patency

• Non-venting caps for ease of set-up for

VAVD procedures (except inlet, outlet,

vacuum and recirculation caps)

0

2

4

6

8

Qblood (L/min)

O

2

(mL/min)

500

400

300

200

100

0

O

2

Transfer Rate

FiO

2

100%

80%

60%

gas:blood flow = 1:1

0

2

4

6

8

Qblood (L/min)

E

0.9

0.8

0.7

0.6

0.5

0.4

0.3

Heat Exchange Effectiveness

10.0

14.0

18.0

Qwater (L/min)

0

2

4

6

8

Qblood (L/min)

CO

2

(mL/min)

500

400

300

200

100

0

CO

2

Transfer Rate

.5:1

1:1

2:1

Qgas:Qblood

0

2

4

6

8

Qblood (L/min)

∆P (mm Hg)

100

80

60

40

20

0

Blood Side Pressure Drop

Affinity NT Bench Test Performance information

*

* Representative of an uncoated Affinity NT. Bench data on file. Not necessarily predictive of clinical performance results.

background image

Heparin biocompatible surfaces offered on medtronic oxygenation systems
mimic critical characteristics of the vascular endothelium.

Around the world, leading cardiovascular
surgery teams adopt biocompatible surfaces
as a critical component of comprehensive,
multi-modality strategies to achieve the best
possible outcomes for their patients undergoing
extracorporeal circulation.

Warning: A strict anticoagulation protocol should be followed and anticoagulation should be routinely monitored during all

procedures. The benefits of extracorporeal support must be weighed against the risk of systemic anticoagulation and must be

assessed by the prescribing physician. Contraindication: This device used for any other purposes than for the indicated use is the

responsibility of the user. Warning: gas emboli must be cleared from the extracorporeal circuit before initiating bypass. gas emboli

are hazardous to the patient. if leaks are observed during priming and/or operation, this may result in air embolism to the patient

and/or fluid loss. The extracorporeal circuit must be continually monitored. Do not use the device if these conditions are observed.
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. For a complete listing of indications,

contraindications, precautions and warnings please refer to the instructions For Use which accompany each product.

* Carmeda® is manufactured under license from Carmeda AB for use only as part of an extracorporeal blood circulation system or circuit that

includes an oxygenator or blood pump. Carmeda is a registered trademark of Carmeda AB.

** Technology licensed under agreement from Biointeractions, Limited, United Kingdom.

Surface Design

for

Performance

,

Carmeda

®

*

BioActive Surface

and

Trillium

®

**

Biosurface

background image

Device

Surface

Device

Surface

Schematic provided for illustrative purposes and is not to scale.

Schematic provided for illustrative purposes and is not to scale.

Trillium® Biosurface

Trillium

**

Biosurface provides a blood-contacting surface with heparin, a negative charge and

hydrophilic properities.

Carmeda® BioActive Surface

Featuring durable, non-leaching, End Point Attached Heparin, Carmeda* BioActive Surface has

the largest body of peer-reviewed clinical and scientific evidence of any biocompatible surface

used for cardiopulmonary bypass today. it is an important component of routine as well as complex

extracorporeal circulation procedures.

Platelet

Thrombin

Antithrombin

Covalent Bond

PEO Chain

Heparin

Sulphate/Sulfonate Group

Heparin Active Sequence

End Point Attached Heparin

Platelet

Prime Coat

Prime Coat

Platelet

Platelet

• Non-leaching heparin molecules are

covalently bonded onto the surface
using an end Point Attachment process

• The end Point Attached method

assures that the heparin active
binding sites are properly oriented to
remain free to participate in biological
reactions, similar to the orientation of
heparan sulfate molecules naturally
found on the vascular endothelium

• A high degree of bioactivity is

consistently delivered due to the
unique Carmeda® BioActive Surface
chemistry and its sophisticated
manufacturing process

• Non-leaching heparin molecules are

covalently bonded into the surface

• Sulphate and sulfonate groups are

incorporated into the Trillium®
Biosurface functional layer to provide
a negatively charged surface

• Polyethylene oxide (PeO) chains

are a component of the functional
layer. PeO chains are extremely
hydrophilic along the entire chain,
creating an “insulating” water layer
structure between the blood and
artificial surface

background image

For information on other Medtronic technologies

for extracorporeal circulation, blood processing and

diagnostics, visit: www.perfusion.medtronic.com

World Headquarters

Medtronic, Inc.

710 Medtronic Parkway

Minneapolis, MN 55432-5604

USA

Tel: (763) 514-4000

Fax: (763) 514-4879
Medtronic USA, Inc.

Toll-free: 1 (800) 328-2518

(24-hour technical support for

physicians and medical professionals)

LifeLine

CardioVascular Technical Support

Tel: (877) 526-7890

Tel: (763) 526-7890

Fax: (763) 526-7888

E-mail: rs.cstechsupport@medtronic.com

www.medtronic.com

Oxygenator

Product

Number

Product Description

Units/

case

511

Affinity NT® Hollow Fiber Oxygenator (uncoated)

4

511T

Trillium® Affinity NT® Hollow Fiber Oxygenator

4

CB511

Carmeda® Affinity NT Hollow Fiber Oxygenator

4

Oxygenator w/Reservoir

Product

Number

Product Description

Units/

case

541

Affinity® Hollow Fiber Oxygenator

with integrated Affinity CVR

2

541T

Trillium® Affinity NT® Hollow Fiber Oxygenator

with uncoated integrated Affinity® CVR

2

541TT

Trillium® Affinity NT® Hollow Fiber Oxygenator

with integrated Trillium® Affinity® CVR

2

CB541

Carmeda® Affinity NT Hollow Fiber Oxygenator

with (non-coated) integrated CVR

2

Reservoirs

Product

Number

Product Description

Units/

case

540

Affinity® CVR Cardiotomy/Venous Reservoir

with Filter

4

540T

Trillium® Affinity® CVR Cardiotomy/

Venous Reservoir with Filter

4

321

Affinity Venous Reservoir Bag

8

mVR800

mVR Venous Reservoir Bag • 800 ml

6

mVR1600

mVR Venous Reservoir Bag • 1600 ml

6

CBmVR800

Carmeda® mVR Venous Reservoir Bag • 800 ml

6

CBmVR1600

Carmeda® mVR Venous Reservoir Bag • 1600 ml

6

UC200101366d eN

© medtronic, inc. 2011

All Rights Reserved

Printed in USA

Affinity NT Oxygenerator

Membrane Type:

microporous Polypropylene Hollow Fibers
Membrane Surface Area: 2.5 m

2

Static Priming Volume: 270 ml
Recommended Blood Flow Rate: 1-7 L/min
Maximum Water Side Pressure: 30 psi
Arterial Outlet Port: 3/8"
Venous Inlet Port: 3/8"
Arterial Sample Port: Female Luer Port
Access Port: Female Luer Port
Recirculation Port: 1/4"
Gas Inlet Port: 1/4"
Gas Outlet Port: 3/8" Nonbarbed
Water Ports: 1/2" Quick Disconnects

(Right- and left- hand orientations available

when connected to the Affinity CVR NT

Reservoir)

Affinity CVR NT

Reservoir Volume Capacity: 4000 ml
Recommended Blood Flow Rate: 1-7 L/min
Minimum Operating Level: 200
Cardiotomy Filtration: 30-micron filter
Venous Inlet Screen: 200 micron
Final Reservoir Screen: 150 micron
Size: Adult

Affinity Venous Reservoir Bag

Reservoir Capacity: 1250 ml
Faceplate Volume Settings:

Setting 1: 900 ml

Setting 2: 550 ml
Screen: 105 micron
Venous Inlet: 1/2"
Venous Outlet: 3/8"
Recirculation: 1/4"
Cardiotomy Inlet: 3/8"

MVR Venous Reservoir Bag

MVR800

MVR1600

Reservoir Capacity: 800 ml

1600 ml

Faceplate

Volume Settings:

Setting 1:

450 ml

700 ml

Setting 2:

650 ml

1200 ml

Screen:

105 micron 105 micron

Venous Inlet:

1/2"

1/2"

Venous Outlet:

3/8"

3/8"

Recirculation:

1/4"

1/4"

Cardiotomy Inlet: 3/8"

3/8"


Wyszukiwarka

Podobne podstrony:
Product Brochure117(1)
Product Brochure 66(1)
Product Brochure112(1)
Product Brochure88(1)
Bollfilter UK Product Brochure
Product Brochure11(1)
Product Brochure126(1)
Product presentation XC100FC
~$Production Of Speech Part 2
Product presentation easyControl
Wykład nr 5 podstawy decyzji producenta
gp340 brochure
BrochureWeldability PL spawanie inox
Overview of Exploration and Production
Ek w 5, Producent, 25mar11 [t Nieznany
CM 52 ProductDefinition oct2011
produkcja-pytania, PWR, ZiIP Zarządzanie i Inżynieria Produckji, ZPiU Chlebus
Status producenta na podstawie przepisów prawa w oparciu o praktykę, BHP I PRAWO PRACY, PORADY PRAWN

więcej podobnych podstron