Sprzęt

Termometry

background image

Mercury Free Maximum/Minimum Thermometer

Features:

Temperature Range: -40 to +50°C and -40 to 120°F dual scale
Model 12/408

background image

Deluxe Digital Pocket Thermometer
(HDT303K)

Temperature Range: -50°F to 300°F, -50°C to 150°C

background image

Deluxe Negative Range Infrared Thermometer (IRT9)

Specifications:

Range: -40° to 932°F (-40 to 500°C)

Emmisivity: 3 point selectable

Distance to spot ratio: 10:1

Accuracy: ±3%

Resolution: 1°

background image

Digital Service Thermometer (PT300M)

Specifications:

Temperature Range: -58şF to
302şF (-50şC to 150şC)

Accuracy: ±1.8şF; ± 1şC

Probe Length: 130mm

background image

Digital Single Probe
Thermometer w/Hard Case
& 1 Probe
(DT8801)

Specifications:

Measurement Range:
-58°F to 2000°F (-50°C to
1300°C)

Accuracy: ±0.3% of
reading; ±2°F (±1°C)

Ambient Temperature: 18
to 28°C

background image

Economy Gun-style Infrared

Thermometer (IRT2)

Specifications:

Range: -4° to 500°F (-20 to 260°C)

Accuracy: ±3%

Emmisivity: 0.95 (fixed)

Distance to spot ratio: 6:1

Resolution: 1°

background image

Economy Stick-style

Infrared Thermometer

(IRT5)

Specifications:

Range: -4 to 608°F

Accuracy: ±3%

Emmisivity: 0.95 (fixed)

Distance to spot ratio: 5:1

Response time: 500 m/sec

Resolution: 1°

background image

Fluke 50 Series Thermometers/Dataloggers

Laboratory Accuracy

± 0.05% to 5°F

Type J , K, R, S, T, E, N

.70 inch high, 3 1/2 digit, LCD Display

Measurement Range

-250° C to 1767°, -418°F to 3212°F

Display Resolution

0.1° C/F/K < 1000°, 1° C/F/K < 1000°

background image

Gun Style Infrared
Thermometer
(IRT4)

Special Functions:

Temp. Range: 0 to 788 F (-20 to 420 C)

Accuracy: ±2% of Reading

Emmisivity: 0.95 (Fixed)

Response Time: Every 1 second

background image

Thermometer C 100 Thermometer C 110Thermometer C 120

New Lufft Thermometers

background image

Miernik temperatury HD9016

Zakresy pomiarowe:

termopara typu K: -200°C...1370°C,
termopara typu J: -100°C...750°C,
termopara typu T: -200°C...350°C,
termopara typu E: -200°C...750°C,
termopara typu R: 200°C...1480°C,
termopara typu S: 200°C...1480°C,
termopara typu B: 200°C...1800°C,

Model

HD 9016

Zakres pomiarowy

w zależności od rodzaju termopary

Dokładność

0°C...199.9°C:

+/-

(0.1% wartości mierzonej +0.4°C +1 cyfra)

powyżej 200°C oraz od -200°C...0°C:

+/-

(0.2% wartości mierzonej

+1°C +1cyfra)

Rozdzielczość

w zakresie do 199.9°C: 0.1°C w pozostałym zakresie: 1°C

Wpływ temperatury

0°C/°C dla 18°C...25°C, pozostałe 0,01°C/°C

Jednostka pomiarowa °C, °F

background image

Mierniki temperatury
HD9214/HD9215/HD9219

Sonda zanurzeniowa do pomiarów w cieczach

Sonda powierzchniowa do
pomiarów powierzchni płaskich

Sonda penetrująca do pomiarów
wewnątrz materiałów stałych i
półpłynnych

background image

Precyzyjny laboratoryjny termometr rezystancyjny HPT 98

Dane techniczne:

zakres pomiaru temperatury: 0 do 199.9 st. C

rezystancja czujnika: 0 do 199.9 Om

rozdzielczość pomiaru rezystancji czujnika: 0.1 Om

background image

Infrared Thermometer with Laser
Sighting
(IRT8)

Features:

Laser Sighting

°F & °C Selectable

Backlite

Min/Max

Delta T/Avg

9 Point Memory

Audible Alarm

Fast Operation

Data Hold

Low Battery Indicator

Pocket Sized

background image

LPT600 Easy Temp Laser Thermometer

Features

± 2% Accuracy
± 0.5% of reading, plus one digit repeatability
3:1 Optics ratio with a 1° min. target
Temperature Range 0° to 600°F (-18°C to 315°C)

background image

MT2/MT4 MiniTemp®

Digital Non-Contact

Thermometer

Temperature Range

MT2/MT4: -18 to 260°C (0 to 500°F)

Accuracy
At ambient operating temperature of

23°C (73°F)

MT2/MT4: For targets at -1 to 260° C (30 to 500°F), ±2% of reading or ±2°C (±3.5°F),
whichever is greater

MT2/MT4: For targets at -18 to -1°C (0 to 30°F), ±3°C (±5°F)

Repeatability

MT2/MT4: ±2% of reading or ±2°C (±3°F), whichever is greater

background image

MiniTemp® FS™ Food

Safety Infrared

Thermometer

Temperature Range

MTFS: -30 to 200°C (-25 to 400°F)

Accuracy
At ambient operating temperature of

23°C (73°F)

MTFS: -30 to 0°C: ±1°C +0.1 degree/degree

MTFS: 0 to 65°C: ±1°C

MTFS: above 65°C: 1.5% of reading

Repeatability

MTFS: within accuracy specifications of the unit

background image

Hand-Held Infrared Thermometers

background image

Raynger

®

ST

Pro

and ProPlus

background image

Precyzyjny termometr rezystancyjny T20R

model:

T20R-200

T20R-600

zakres pomiarowy, °C:

-50 ÷ 200

-50 ÷ 600

rozdzielczość wskazań, °C:

0,01

0,1

rozszerzona niepewność,

95%:

± 0,05 % wartości mierzonej

typy czujników:

platynowy, niklowy, miedziany

background image

Stick-style Infrared Thermometer

with Laser (IRT6)

Specifications:

Range: -4° to 788°F

Accuracy: ±3%

Emmisivity: 0.95 (fixed)

Distance to spot ratio: 8:1

background image

Temperature/Hu
midity Pen with
Calibration
Salts
(PTH8709K)

Specifications:

Temperature Range: 14 şF to 122şF (-10 şC to 50şC)

Temperature Accuracy: ±1.8 şF (±1şC)

Humidity Range: 5% to 95%

Humidity Accuracy: ±5%

Resolution: 0.1ş

background image

Termometry z serii COMMETER

PARAMETRY TECHNI CZNE (modele C01..., D01... i D02...)

Liczba kanałów pomiarowych:

1, 2 lub 4

Zakres pomiarowy:

-200...500°C (Pt1000, 3850ppm/ °C - tylko D02)
-50...250°C (Ni1000, 6180ppm/°C)

Dokładność wejścia
temperaturowego (Pt1000)
(tylko D02) :

±0.3°C (-200...+100°C)
±0.3% w. o. (100...500°C)

Dokładność wejścia
temperaturowego (Ni1000):

±0.2°C (-50...+100°C)
±0.2% w. o. (100...250°C)

Rozdzielczość wskazań
temperatury:

0.1°C (-99.9...500°C)
1°C w pozostałym

PARAMETRY TECHNI CZNE (modele C03... i D03...)

Liczba kanałów
pomiarowych:

1 lub 2

Zakres pomiarowy:

-200...750°C (termopara J )
-200...1300°C (termopara K)
-50...1700°C (termopara S)

Dokładność wejścia
pomiarowego:

±(0.4°C +0.1% w.o.) - termopara J
±(0.4°C +0.1% w.o.) - termopara K
±(0.85°C +0.1% w.o.) - termopara S

Rozdzielczość wskazań
temperatury:

0.1°C (termopary J i K -99.9...999.9°C)
1°C (termopary J i K w pozost. zakresie)
0.4°C (termopara S -50.0...999.9°C)
1°C (termopara S >1000°C)

background image

THP1 Thermo-Hygrometer Pen

Humidity Range 5% to 95% RH
Accuracy 10% to 90% RH ± 3% All other ranges
± 5%
Temperature Range +14°F to +122°F (-10°C to
50°C)

background image

Pirometry

8859 8866 8886 8889

Zakres pomiarowy [°C]

-20..+420

Błąd pomiaru +/-[%]

2..3

Rozdzielczość [°C]

1

Rozdzielczość optyczna

8:1

10:1 8:1

8:1

Współczynnik emisyjności (0,3..1,0)

0,95 regulowany

Czas pomiaru [ms]

500

Pirometry Unilap

background image

Adjustable Angle Industrial Thermometers

background image

Termometr DRT-11

Dane Techniczne

wersja DRT-11-200

wersja DRT-11-600

zakres pomiarowy

-50

o

C do +200

o

C

-50

o

C do +600

o

C

rozdzielczość

0,01

o

C

0,1

o

C

max błąd linearyzacji

0,05

o

C

0,3

o

C

temperatura pracy

0

o

C do 40

o

C

wpływ temperatury

otoczenia

mniej niż 0,05

o

C dla całego zakresu temp. pracy

background image

Termometr DRT-20M

Dane Techniczne

wersja DRT-20M-200

wersja DRT-20M-600

zakres pomiarowy

-100

o

C do +200

o

C

-100

o

C do +200

o

C

rozdzielczość

0,01

o

C

0,1

o

C

max błąd linearyzacji

0,05

o

C

0,2

o

C

temperatura pracy

0

o

C do 40

o

C

wpływ temperatury

otoczenia

mniej niż 0,05

o

C dla całego zakresu temp. pracy

background image


Document Outline


Wyszukiwarka

Podobne podstrony:
sprzet lab profilografy
sprzet lab mikromanometry
sprzet lab baro higrometry
sprzet lab inne
sprzet lab 1
sprzet lab pirometry
sprzet lab profilografy
sprzet lab mikromanometry
sprzet lab baro higrometry
Termometr, EiT Studia, IV ROK, Przedmiot wyb. Zmarzły - Lab
Badanie sprzętu ochronnego-lab, badanie sprzętu ochronnego, Politechnika Radomska
spis lab I sem 2010
III WWL DIAGN LAB CHORÓB NEREK i DRÓG MOCZ
sprzet SGRW
postępowanie ze sprzętem jednorazowym ASEPTYKA
Diagnostyka lab wod elektrolit
ZW LAB USTAWY, OCHRONA
T 1 4 Dezynfekcja rąk i sprzętu medycznego

więcej podobnych podstron