Motorola Confidential
Proprietary
•Gopi - Logic. – 9.15am
•Budi - Camera - 9.30am
•Gary - Blue-tooth , Rotator -
10am
•Lee Ming - RX. 10.30am
•David - TX. 11am
•Leng - PM/P-Flex/Keypad
11.30am
•Pang - Audio 12pm
•AOB - 12.30pm
V80 Analyzing Training
Motorola Confidential
Proprietary
V80 Logic
26MHz Crystal
CKO = 52MHz
Testpoint
Neptune powersupply
Pins/bypass caps
Decoder IC, not used
For V80
PSRAM Mode Resistor
Motorola Confidential
Proprietary
V80 Memory U700
Flash Memory Size: 256Mbit
(24 address lines)
PSRAM Memory Size: 64Mbit
(22 address lines)
Flash and
PSRAM in a
single chip
High voltage
programming
test point. Can be
used
to check if the flash
is
getting power
R897 PSRAM Mode
Resistor. Without this
resistor, phone will
not turn on
C702, C703, C700,C701
Power supply bypass caps.
Vbuck = 1.87V
Two suppliers: Intel and STM
Motorola Confidential
Proprietary
Neptune Voltages
Signal Name
Typical Vdc
Cap to Probe
Comments
VDDA
2.775V
C806
VDD_CP
5V
C819
VDD1,2,3,4,RE
G_
BYP_CORE
1.875V
C810,C826,C8
27,C829
AVDD1 to 7
1.875V
C811,C812,C8
13
BVDD,CVDD,
DVDD, JVDD
2.775V
C815,C816,C8
17
FVDD
1.875V
LVDD
1.55V
C807
QVDD
1.875V
C814
VDD_TXRX
2.775V
Motorola Confidential
Proprietary
CKO Capture
Motorola Confidential
Proprietary
Neptune STANDBY Level shifter IC
U801 – Level shifter IC
Purpose: Shift the the input voltage
of 1.575V to an output voltage of
2.775V.
Neptune outputs the “STANDBY”
signal to PCAP.
1.575V
2.775V
2.775V
Motorola Confidential
Proprietary
V80 Testpoints
Short IO_REG and WDOG testpoints for No power up failure troubleshoot
Good Phone
Without shorting WDOG and IO_REG, WDOG must be at 2.775V at all times
2.775V
Motorola Confidential
Proprietary
Troubleshooting Tips
• The radio draws 40mA to 60mA of current when the
flash is blank (empty flash/ not programmed)
• A bricked phone will draw more current than a blank
flash phone
• When a phone bricks and if the IMEI is not
programmed, you can save the phone by using the
erase_rom.shx file
• If IMEI is already programmed and phone bricks,
replace the flash with a empty flash
• Place a short between WDOG and IO_REG before
starting a No power up troubleshooting