creating pod for axe example3 466PAUI4ZXJVIG5FOF2WCJKKF25ZWNBRFUROXWY


FRAME HANDLER DATA LINK CONNECTION DETAILS ERICSSON ///  Example 311/1013-FCK 114 62 Uen, A PRINTOUT DESCRIPTION  Uppgjord - PreparedETXMALS Faktaansvarig - Subject responsibleEEI/SPH HAXE Nr - No3/190 83-CNT 123 9999 Uen Dokansv/Godk - Doc respons/ApprovedUAB/K/UEC (Henrik Almeida) Kontr - CheckedEEIGCN Datum - Date1996-11-15 RevA File  FRAME HANDLER DATA LINK CONNECTION DETAILS 1   Format 1.1   Printout 1.1.1   Format 1 FRAME HANDLER DATA LINK CONNECTION DETAILS DEVICE ORDER DEV TWINDEV FHLDEV ACCDEV SNB1 LIC3 LIC2 dev [twindev] fhldev accdev snb1 lic3 lic2 . . . . . . . . . . . . accdev snb1 lic3 lic2 . . . fhldev accdev snb1 lic3 lic2 . . . . . . . . . . . . accdev snb1 lic3 lic2 [EOT DURING PRINTOUT] / \ |FAULT INTERRUPT| |fault type | \ / END 1.1.2   Format 2 FRAME HANDLER DATA LINK CONNECTION DETAILS SUBSCRIBER ORDER SNB2 ACCDEV FHLDEV DEV TWINDEV LIC3 LIC2 snb2 accdev fhldev [dev] [twindev] [lic3] lic2 . . . . . . . . . . . . . . . . . . . . . snb2 accdev fhldev [dev] [twindev] [lic3] lic2 [EOT DURING PRINTOUT] / \ |FAULT INTERRUPT| |fault type | \ / END 1.2   Parameters accdevISDN basic access device devFrame Handler Concentrator (FHC) device fhldevFrame Handler Local (FHL) device connected to the FHC lic2Link identification code 2This parameter is the internal basic access number. lic3Link identification code 3This parameter is the local frame handler reference. snb1Access Default Number (ADN) snb2Subscriber number connected to the access twindevFHC twin device EOT DURING PRINTOUT The operator has cancelled the printout. FAULT INTERRUPT fault type A fault interruption occurred during printing. Fault type: UNREASONABLE VALUE details The parameter was specified with an unreasonable value. FAULT CODE 9 THE SUBSCRIBER IS NOT CONNECTED TO THE FH FUNCTION details The subscriber is not connected to the Frame Handler function. 2   Function 2.1   Format 1 This printout is received as an answer printout to command FHDLP when parameter DEV is specified. It lists the device, the twin, and the devices connected by the semipermanent connection on the IBD side. The following information is listed for each of these devices: Access devices Default number Link identification code 2 (internal basic access number) Link identification code 3 (local frame handler reference) 2.2   Format 2 This printout is received as an answer printout to command FHDLP when parameter SNB is specified. It lists the subscriber number, the access device, the FHL device, and link identification code 2 (the internal basic access number). If the FHL device is semipermanently connected, the FHC device connected on the other side of the IBD channel, the FHC twin device and link identification code 3 (the local frame handler reference) are also printed. 3   Action - 4   Printout Type Answer printout 5   Printout Block FHA 6   Glossary ADN Access Default Number FHC Frame Handler Concentrator FHL Frame Handler Local 7   References 8   Command Descriptions FHDLP Frame Handler Data Link Connection, Print

Wyszukiwarka

Podobne podstrony:
creating pod for axe example2
creating pod for axe example4
creating pod for axe example1
creating cod for axe example3
creating cod for axe example4
creating cod for axe example5
creating cod for axe example5
creating cod for axe example1
creating cod for axe example2
creating pod for axe
creating cod for axe
phrases for giving examples practice game
creating customers for life
drugs for youth via internet and the example of mephedrone tox lett 2011 j toxlet 2010 12 014
2001 08 Creating Boot Cds for a Quick Recovery
How to Write a Brief for a Creative Advertising Agency
Managing brands for value creation
Brandy Corvin Howling for the Vampire

więcej podobnych podstron