FRAME HANDLER DATA LINK CONNECTION DETAILS
ERICSSON ///
Example 311/1013-FCK 114 62 Uen, A
PRINTOUT DESCRIPTION
Uppgjord - PreparedETXMALS
Faktaansvarig - Subject responsibleEEI/SPH HAXE
Nr - No3/190 83-CNT 123 9999 Uen
Dokansv/Godk - Doc respons/ApprovedUAB/K/UEC (Henrik Almeida)
Kontr - CheckedEEIGCN
Datum - Date1996-11-15
RevA
File
FRAME HANDLER DATA LINK CONNECTION DETAILS
1 Format
1.1 Printout
1.1.1 Format 1
FRAME HANDLER DATA LINK CONNECTION DETAILS
DEVICE ORDER
DEV TWINDEV FHLDEV ACCDEV SNB1 LIC3 LIC2
dev [twindev] fhldev accdev snb1 lic3 lic2
. . . .
. . . .
. . . .
accdev snb1 lic3 lic2
.
.
.
fhldev accdev snb1 lic3 lic2
. . . .
. . . .
. . . .
accdev snb1 lic3 lic2
[EOT DURING PRINTOUT]
/ \
|FAULT INTERRUPT|
|fault type |
\ /
END
1.1.2 Format 2
FRAME HANDLER DATA LINK CONNECTION DETAILS
SUBSCRIBER ORDER
SNB2 ACCDEV FHLDEV DEV TWINDEV LIC3 LIC2
snb2 accdev fhldev [dev] [twindev] [lic3] lic2
. . . . . . .
. . . . . . .
. . . . . . .
snb2 accdev fhldev [dev] [twindev] [lic3] lic2
[EOT DURING PRINTOUT]
/ \
|FAULT INTERRUPT|
|fault type |
\ /
END
1.2 Parameters
accdevISDN basic access device
devFrame Handler Concentrator (FHC) device
fhldevFrame Handler Local (FHL) device connected to the FHC
lic2Link identification code 2This parameter is the internal basic access number.
lic3Link identification code 3This parameter is the local frame handler reference.
snb1Access Default Number (ADN)
snb2Subscriber number connected to the access
twindevFHC twin device
EOT DURING PRINTOUT
The operator has cancelled the printout.
FAULT INTERRUPT
fault type
A fault interruption occurred during printing.
Fault type:
UNREASONABLE VALUE
details
The parameter was specified with an unreasonable
value.
FAULT CODE 9
THE SUBSCRIBER IS NOT CONNECTED TO THE FH FUNCTION
details
The subscriber is not connected to the Frame
Handler function.
2 Function
2.1 Format 1
This printout is received as an answer printout to command FHDLP when parameter DEV is specified. It lists the device,
the twin, and the devices connected by the semipermanent
connection on the IBD side.
The following information is listed for each of these devices:
Access devices
Default number
Link identification code 2 (internal basic access number)
Link identification code 3 (local frame handler reference)
2.2 Format 2
This printout is received as an answer printout to command FHDLP when parameter SNB is specified. It lists the subscriber
number, the access device, the FHL device, and link identification
code 2 (the internal basic access number).
If the FHL device is semipermanently connected, the FHC device
connected on the other side of the IBD channel, the FHC twin device
and link identification code 3 (the local frame handler reference)
are also printed.
3 Action
-
4 Printout Type
Answer printout
5 Printout Block
FHA
6 Glossary
ADN
Access Default Number
FHC
Frame Handler Concentrator
FHL
Frame Handler Local
7 References
8 Command Descriptions
FHDLP
Frame Handler Data Link Connection, Print
Wyszukiwarka
Podobne podstrony:
creating pod for axe example2creating pod for axe example4creating pod for axe example1creating cod for axe example3creating cod for axe example4creating cod for axe example5creating cod for axe example5creating cod for axe example1creating cod for axe example2creating pod for axecreating cod for axephrases for giving examples practice gamecreating customers for lifedrugs for youth via internet and the example of mephedrone tox lett 2011 j toxlet 2010 12 0142001 08 Creating Boot Cds for a Quick RecoveryHow to Write a Brief for a Creative Advertising AgencyManaging brands for value creationBrandy Corvin Howling for the Vampirewięcej podobnych podstron