FHDLPFrame Handler, Data Link Connection, Print
1 Format
1.1 Command
/ \
|DEV=dev |
FHDLP:+ +;
|SNB=snb...|
\ /
1.2 Parameters
DEV=devFrame Handler Concentrator (FHC) device
Expressed as FHC-n where:
FHCDevice type
nDevice number
Numeral 0 - 65535
The maximum value is defined by Size
Alteration Event (SAE) 500 in block FHC.
SNB=snbSubscriber number
Numeral 1 - 20 digits
2 Function
This command prints the data link connection identifier
information including link identification code 2 and 3, for a
FHC device or for the specified subscriber numbers.
Answer printout FRAME HANDLER DATA LINK CONNECTION DETAILS
is received.
If parameter
DEV is specified, the FHC twin device, the Frame
Handler Local (FHL) device, the ISDN basic access, and its
subscriber numbers are also printed.
If parameter
SNB is specified, the device connected to the subscriber
number, the FHL device, the FHC, and its twin are also printed.
For a group number, only the group number lines are printed as
device information.
The order does not remain after system restart.
3 Examples
3.1 Example 1
FHDLP:DEV=FHC-0;
The data link connection for device FHC-0 is printed. All the
devices connected to this device by the semipermanent function
are printed (twin and local devices, ISDN basic access devices,
subscriber number, and link identification codes).
3.2 Example 2
FHDLP:SNB=43210000&&43210009;
The data link connection for subscribers 4321000 to 43210009 is
printed. All the devices connected to each subscriber are
printed with the link identification codes.
4 Printouts
4.1 Check Printout
Not relevant.
4.2 Procedure Printouts
NOT ACCEPTED
fault type
fault type
FUNCTION BUSY
The function busy is busy.
FORMAT ERRORdetails
The command was incorrectly specified.
UNREASONABLE VALUEdetails
The parameter was specified with an unreasonable value.
FAULT CODE 1
INCORRECT TYPE OF DEVICE
The specified device is not a frame handler
device, or is a device not used by the command.
FAULT CODE 7
THE DEVICE DOES NOT EXIST
The specified device does not exist.
FAULT CODE 9
THE SUBSCRIBER IS NOT CONNECTED TO THE FH FUNCTION
details
The subscriber is not connected to the Frame
Handler function.
FAULT CODE 10
THERE IS NO SEMIPERMANENT CONNECTION TOWARDS FHL DEVICE
There is no semipermanent connection towards
the FHL device for the specified FHC.
4.3 Answer Printouts
FRAME HANDLER DATA LINK CONNECTION DETAILS
4.4 Result Printouts
-
5 Logging
Not relevant.
6 Command Category Group
Recommended value
0
(H'0).
7 Command Receiving Block
FHA
8 Glossary
FHC
Frame Handler Concentrator
FHL
Frame Handler Local
SAE
Size Alteration Event
9 References
10 Printout Descriptions
FRAME HANDLER DATA LINK CONNECTION DETAILS
11 Application Information
FHC
Wyszukiwarka
Podobne podstrony:
creating cod for axe example3creating cod for axe example4creating cod for axe example1creating cod for axe example2creating pod for axe example2creating pod for axe example4creating cod for axecreating pod for axe example1creating pod for axe example3creating pod for axephrases for giving examples practice gamecreating customers for lifedrugs for youth via internet and the example of mephedrone tox lett 2011 j toxlet 2010 12 0142001 08 Creating Boot Cds for a Quick RecoveryHow to Write a Brief for a Creative Advertising AgencyManaging brands for value creationBrandy Corvin Howling for the Vampirewięcej podobnych podstron