315, 355 kW, 2SG3 2 400S 4f, 2SG3 2 400M 4f


Form No. F  K400037/8B
CATALOGUE CARD K4-15-144
DFME
ISSUE 1
MINING INDUCTION MOTORS
DAMEL S.A.
2SG3(2) 400S-4f, 2SG3(2) 400M-4f
PAGE 1/1
APPLICATION
One-speed motors of type 2SG3(2) mechanical value of 400 are intended for driving mining machines and
equipment , especially for driving belt conveyors and scraper belt conveyors.
The motors can be used in underground parts of mines and surface installations of the mines, where there are
possible explosion conditions for methane and/ or coal dust.
There is also possible to operate the motors in the surroundings where the explosion-proof equipment is not
required.
CHARACTERISTIC FEATURES OF MOTORS
" Induction 3-phase motors with squirrel-cage rotor.
" Explosion-proof construction with flame-proof casing of motor  d - mark I M2 EExd I,
equipment ranked as group I of category M2 according to Directive 94/9/EC.
" The degree of protection IP 55 acc. to PN-EN 60034-5:2002U.
" The motors are cooled by water flowing through channels in body and connected with it in series channel of
bearing disk P.
" Form of execution : flanged execution  IM 3001(B5); arm - flanged execution  IM 2001(B3/B5); flange
FF740.
" Basic voltage execution: 1000; 1140V  50Hz
After settlement it is possible to execute the motors for other voltage and frequency of 60Hz.
" Class of insulation: class H  primary execution, class H + reinforced wound insulation  execution against
order,
" Thermal protection of motors: bimetal sensors NC or posistor PTC sensors in winding and bearing nodes 
two identical circuits basic and stand-by .
" Temperature control: thermometric resistors Pt100 in winding and bearing nodes (execution against order).
" Two-inlet terminal box equipped with one or two cable inlets with rubber gaskets selected to the outer
diameter of conductors , type Wk3u/d .. prod. DAMEL (Catalogue Card K4-15-136).
" The motor is equipped with the final link of protection conductor continuity control circuit, mounted in the
terminal box  primary execution: final unit CK-0A
After settlement the assembly of final unit CK of other type is possible (e.g. diode+resistor, reverse polarity,
etc.) produced by DAMEL (Catalogue Card K4-15-121).
" Feeding and start-up: the motors are intended for feeding from power network  start-up by direct switching
on the voltage.
Motors executed in class of insulation H with reinforced wound insulation can be supplied from frequency
converters of class MSI (PWM)  the range of working frequency 0÷50Hz.
" The motors adapted for work in temperate climate; after settlement the adaptation for work in tropical climate
TA or TH is possible.
COMPATIBILITY WITH REQUIREMENTS OF STANDARDS
The motors meet requirements of Directive 94/9/EC (ATEX), European harmonized standards and domestic
norms:
- norms for electrical equipment in areas of explosion hazard:
- EN 50014:1997+A1:1999+A2:1999  Polish equivalent PN-EN 50014:2002U,
- EN 50018:2000+A1:2002  Polish equivalent PN-EN 50018:2002U,
- EN 50019:2000  Polish equivalent PN-EN 50019:2002U,
- norms for rotational electric machines:
- EN 60034-1:1998+A1:1998+A2:1999+AC:2000  Polish equivalent PN-EN 60034-1:2001
- domestic norms for induction motors for mining machines:
- PN G-38010:1997 (domestic norm).
CERTIFICATES
- Certificate EC (ATEX) issued by notified Testing Station GIG KD  BARBARA , valid on the area of
European Union
- Certificate of Russian Testing Station !  !5@B8C< , valid on the area of Russian Federation.
File No: 315, 355 kW, 2SG3(2) 400S-4f, 2SG3(2) 400M-4f.doc/2005
Translated by: PTU -DAMAR- Sosnowiec
Form No. F  K400037/8B
CATALOGUE CARD K4-15-144
DFME
ISSUE 1
MINING INDUCTION MOTORS
DAMEL S.A.
2SG3(2) 400S-4f, 2SG3(2) 400M-4f
PAGE 2/2
TECHNICAL DATA
Table 1
Parameters 2SG3 400S-4f 2SG3 400M-4f
2SG2 400S-4f 2SG2 400M-4f
[kW] 315 355
Rated power PN
Current at rated voltage IN[A] 1000V 211 240
IN[A] 1140V 185 210
0,9 0,9
Power coefficient cosĆ
[%] 95 95
Efficiency ·
Rotational speed n [1/min] 1478 1474
Rated moment MN [Nm] 2035 2300
6,5 6,6
Multiplicity of start-up current IK/IN
2,7 2,8
Multiplicity of start-up moment MK/MN
2,6 2,4
Multiplicity of critical moment Mmax/MN
Min. flow of cooling water [dm3/min] 12 12
Mode of operation S1;
S4-60%, Jext/JM=1, 40c/h
Rotor moment of inertia JM kgm2 11 13
Mass of motor: flanged execution 2300 2400
kg
Arm-flanged execution 2380 2480
1. The parameters of motor: rated current, efficiency, power factor, rotational speed and rated moment
relate to rated load at rated feeding conditions  50Hz.
2. Multiplicities of start-up current , start-up moment and critical moment refer to direct connection of the
motor to the supply network (mains).
3. Jext  inertia moment of motor load referred to the shaft of motor
bearing
bearing
winding
bimetals NC
or posistors
PTC
thermometric
resistors Pt 100
Fig. 1 Diagram of motor connections
 winding, protective terminals, thermal protection.
Highpressure hose
Water outlet
Water inlet
Body Disk P
Fig. 2 Diagram of cooling system
File No: 315, 355 kW, 2SG3(2) 400S-4f, 2SG3(2) 400M-4f.doc/2005
Translated by: PTU -DAMAR- Sosnowiec
Form No. F  K400037/8B
CATALOGUE CARD K4-15-144
DFME
ISSUE 1
MINING INDUCTION MOTORS
DAMEL S.A.
2SG3(2) 400S-4f, 2SG3(2) 400M-4f
PAGE 3/3
Water inlet
Water outlet
Centre hole M20
View W
View P
4 holes
Water inlet
Cable inlet
Stopper or
cable inlet
Water outlet
Flange Cable inlets
Form of Shaft of the motor Diagram
Type of motor
(basic of cooling
execution
acc. to
execution system
acc. to
Fig. 2
Forms of execution: IM 3001 (B5)  flanged
IM 2001 (B3/B5)  arm-flanged
Fig. 3 Overall and assembly dimensions of motors.
File No: 315, 355 kW, 2SG3(2) 400S-4f, 2SG3(2) 400M-4f.doc/2005
Translated by: PTU -DAMAR- Sosnowiec
Form No. F  K400037/8B
CATALOGUE CARD K4-15-144
DFME
ISSUE 1
MINING INDUCTION MOTORS
DAMEL S.A.
2SG3(2) 400S-4f, 2SG3(2) 400M-4f
PAGE 4/4
CONDITIONS OF OPERATION AND APPLICATION
" Ambient temperature 0o÷40oC
" Relative humidity at temperature of 35oC 97÷100%
" Height above the sea level d" 1000m
" Degree of corrosive aggressiveness C acc. to PN-71/H-04651
" Admissible inclination of the shaft axis to level d" 30oC
" Parameters of cooling water at inlet of cooling system
- maximum temperature + 30oC
- maximum static pressure 3MPa
" Supply voltage (0,95÷1,05)UN
" Electrical terminal
Power supply connection  mining flexible line with rubber coated and insulation, multicore,
screened for the voltage of 0.6/1kV with section area of cores selected to operating conditions.
Connection of circuits of temperature sensors and temperature control thermometric elements  auxiliary
cores of feeder flexible line or multicore (control) flexible line with section area of conductors up to 4mm2.
When connecting the motor with one conductor the other inlet of terminal box is FLP stopped by stopper
Zk3u.
" Leading the flexible lines to terminal box through cable inlets selected according to the outer diameter of
conductors acc. to table 3.
Table. 3
Type of inlet Cable The range of diameters of conductors for cable inlets
Wk3u/d80 40÷44 41÷46 44÷49 48÷53 52÷57
Feeder
Wk3u/d100 55÷61 59÷65 62÷68 68÷74
Wk3u/d47 Control 19÷21 20÷24 22÷26
In case the Orderer does not state the type of cable inlet (outer diameter of conductor) the motor is
delivered with cable inlet and stopper acc. to table 2.
OFFER FOR DELIVERIES OF MOTORS
The producer offers motors in primary execution and in options executed against the order from offeree
(additional, diversified equipment).
Table 4
Constructional Primary execution Execution against order
characteristic of motor
1 2 3
rated voltage 1000; 1140V other voltage
frequency 50Hz 60Hz
Form of execution flanged IM 3001(B5) arm - flanged IM 2001 (B3/B5)
class of insulation H H + reinforced wound insulation
thermal posistor PTC
protection  type of sensors bimetal NC
temperature control
 thermometric resistors Pt100
 thermometric elements
One inlet Wk3u/d100-55÷61
One or two cable inlets Wk3u
Cable inlets +stopper Zk3u
- see table 3
- see table 2
final link CK & appointed by Orderer
CK-0A
of control circuit (acc. to catalogue card K4-15-121)
climatic execution for temperate climate for tropical climate TH or TA
acc. to settlements, it can require
constructional characteristic
 acceptance of the unit certifying the
other than above mentioned
product
The following items are included to the delivered motor:
- running-technical documentation (RTD  Technical & Operational Documentation of the motor).
- declaration of conformity EC.
File No: 315, 355 kW, 2SG3(2) 400S-4f, 2SG3(2) 400M-4f.doc/2005
Translated by: PTU -DAMAR- Sosnowiec
Form No. F  K400037/8B
CATALOGUE CARD K4-15-144
DFME
ISSUE 1
MINING INDUCTION MOTORS
DAMEL S.A.
2SG3(2) 400S-4f, 2SG3(2) 400M-4f
PAGE 5/5
ORDERING PROCEDURE
The following data should be stated in the order directed to the address of manufacturer given below:
- type of motor, power
- rated voltage and frequency
- motor execution: preliminary  see table 4 column 2 or execution against order, for which
required equipment and constructional characteristic should be determined acc. to table 4
column 3.
When ordering we recommend to fill up the questionnaire  Statement of technical data of the motor... 
accessible at internet (web) sites and in Marketing Department of DFME DAMEL.
The producer offers additionally:
- guarantee and after guarantee service,
- delivery of spare parts,
- training of employees in the range of correct maintenance and operating the motor.
Producer reserves the right to implement to the motor changes resulting from technical progress.
DÄ…browska Fabryka Maszyn Elektrycznych DAMEL S. A.
Aleja Józefa Piłsudskiego 2, 41-300 Dąbrowa Górnicza, POLSKA, tel: (32) 262-32-30 do 39
Faks (32) 264-34-26, 264-10-12, http: www.damel.com.pl, email: office@damel.com.pl
Elaboration:  DAMEL  TK/PG/10/2004
File No: 315, 355 kW, 2SG3(2) 400S-4f, 2SG3(2) 400M-4f.doc/2005
Translated by: PTU -DAMAR- Sosnowiec


Wyszukiwarka

Podobne podstrony:
400 kW, 2SG3 450S 4
85 250, 105 315 kW, 2SGS 355L 12 4, 2SGS 400S 12 4
Kw 1 (2)
kw spis
300 kW, 3300V, SG4 562Y 4
Brother Fax 255, 275, 355, 375, 515, 525 Parts Manual
Cechy Transp Kw B R
KW LAN Wstep
SPI 315 34
RP PKB ZA II KW
kw (2)
readme (355)
cgi ebay de KW QRP SGC SG 2020 top Zustand original unve d20070211 t014709
KW3 S

więcej podobnych podstron