POLITECHNIKA LUBELSKA W LUBLINIE |
||||
Laboratorium Podstaw Elektrotermii |
Nr ćwiczenia: 3T/4T |
Data wyk: |
||
Temat: „Wyznaczanie ciepła akumlacyjnego elektrycznego pieca komorowego nieprzelotowego. Badanie strat cieplnych w piecu oporowym komorowym”.” |
Wykonanie: |
|||
Ocena: |
Data: |
Podpis: |
1. Schemat układu
2. Tabela pomiarowa
t |
Wyłacz. |
Włącz. |
P |
Pz |
T1 |
T2 |
T3 |
T4 |
T5 |
T6 |
Tzew |
Ps |
Treg |
Tz |
min |
min |
min |
W |
w |
oC |
oC |
oC |
oC |
oC |
oC |
oC |
W |
oC |
oC |
0 |
|
|
2600 |
2600 |
40 |
40 |
40 |
40 |
40 |
40 |
30 |
91,74 |
20 |
37,14 |
5 |
|
|
2600 |
2600 |
40 |
40 |
40 |
40 |
40 |
40 |
35 |
119,97 |
100 |
48,57 |
10 |
|
|
2600 |
2600 |
40 |
40 |
40 |
40 |
40 |
40 |
35 |
179,96 |
270 |
72,86 |
15 |
|
|
2600 |
2600 |
40 |
90 |
40 |
80 |
40 |
40 |
35 |
239,94 |
350 |
97,14 |
20 |
|
|
2600 |
2600 |
40 |
110 |
50 |
100 |
40 |
40 |
35 |
275,23 |
400 |
111,43 |
25 |
|
|
2600 |
2600 |
40 |
120 |
50 |
120 |
40 |
40 |
35 |
303,46 |
450 |
122,86 |
30 |
|
|
2600 |
2600 |
45 |
140 |
50 |
160 |
40 |
40 |
36 |
336,98 |
480 |
136,43 |
35 |
|
|
2600 |
2600 |
50 |
170 |
60 |
190 |
40 |
40 |
36 |
381,09 |
530 |
154,29 |
40 |
|
|
2600 |
2600 |
50 |
190 |
60 |
220 |
40 |
40 |
37 |
405,79 |
550 |
164,29 |
45 |
|
|
2600 |
2600 |
50 |
210 |
60 |
250 |
40 |
40 |
37 |
430,49 |
570 |
174,29 |
50 |
|
|
2600 |
2600 |
60 |
220 |
70 |
280 |
40 |
40 |
37 |
462,24 |
600 |
187,14 |
55 |
|
|
2600 |
2600 |
60 |
240 |
80 |
300 |
40 |
40 |
38 |
486,94 |
620 |
197,14 |
60 |
|
|
2600 |
2600 |
60 |
260 |
80 |
320 |
40 |
40 |
38 |
508,11 |
640 |
205,71 |
1.05 |
|
|
2600 |
2600 |
70 |
280 |
80 |
340 |
40 |
40 |
39 |
529,29 |
650 |
214,29 |
1.10 |
|
|
2600 |
2600 |
70 |
290 |
90 |
350 |
40 |
40 |
39 |
543,40 |
660 |
220,00 |
1.15 |
|
|
2600 |
2600 |
70 |
310 |
100 |
370 |
40 |
40 |
39 |
568,10 |
680 |
230,00 |
|
1.17 |
|
|
|
70 |
310 |
100 |
370 |
40 |
40 |
39 |
|
690 |
231,43 |
|
|
1.18 |
2600 |
2100 |
70 |
320 |
100 |
380 |
40 |
40 |
39 |
568,10 |
660 |
230,00 |
|
1.23 |
|
|
|
80 |
320 |
120 |
380 |
40 |
40 |
39 |
|
690 |
238,57 |
|
|
1.24 |
2600 |
800 |
80 |
330 |
120 |
400 |
40 |
40 |
39 |
592,80 |
670 |
240,00 |
|
1.28 |
|
|
|
80 |
330 |
120 |
420 |
40 |
40 |
40 |
|
690 |
245,71 |
|
|
1.29 |
2600 |
600 |
80 |
330 |
120 |
420 |
40 |
40 |
40 |
600 |
670 |
242,86 |
3. Przykładowe obliczenia
Wyznaczenie ciepła zakumulowanego:
VszI=12,5 dm3
VszII=57 dm3
VtIII=184 dm3
τ = 89min=1.29h
Pśr= PZśr -PSśr=2373,68-426,88=1946,8 [W]
Q = m*c* ∆t
m = V*ρ
Q = V* ρ*c*∆t
Q1= 12,5 * 1,9 * 0,2 * (522,5 - 40) = 2291,9[kcal]
Q2= 57 * 0,5 * 0,2 * (237,5 - 40) = 1125,75 [kcal]
Q3= 184 * 0,4 * 0,2 * (70 - 40)=441 [kcal]
Q=Q1+Q2+Q3 = 3858,65[kcal] - energia wyliczona z pomiarów
Qo=1946,8*1,29 =2511,37[Wh] - energia wyliczona mocy średniej do czasu nagrzewu
4. Wnioski:
Obilczenie średniej temperatury warstwy: