POMIAR POJEMNOSCI KONDENSATORA METODA MOSTKA WHEATSTONE 'A
WSTEP .
--------------
PRZY POMOCY URZADZENIA ZWANEGO MOSTKIEM WHEATSTONE'A MOZEMY
ZBADAC NIEZNANE POJEMNOSCI KONDENSATORW . W DOSWIADCZENIU SZUKAMY
POJEMNOSCI KONDENSATORW
. ZNAJDUJEMY JE POPRZEZ DOBRANIE
ODPOWIEDNIEJ WARTOSCI KONDENSATORA DEKADOWEGO , TAK ABY NATEZENIE
DZWIEKU W SLUCHAWKACH BYLO JAK NAJMNIEJSZE . NATEZENIE DZWIEKU OSIAGALO
WARTOSCI MINIMALNE , GDY PRAD NIE PLYNAL . WTEDY POMIEDZY PUNKTEM E I D NIE
MA RZNICY POTENCJALW . WWCZAS:
OZNACZAJAC PRADY ODPOWIEDNIO
PRAD NA ODCINKU ADB
-PRAD NA ODCINKU AEB
ZE WZGLEDU NA RWNOSC ODPOWIEDNICH NAPIEC , PO PODSTAWIENIU
OTRZYMUJEMY :
Z
TEJ RWNOSCI WYNIKA , ZE
.
OPIS WYKONYWANYCH CZYNNOSCI :
--------------------------------------------------------------
1.MONTUJEMY ZESTAW WEDLUG SCHEMATU .
2.DOBIERAJAC ODPOWIEDNIE WARTOSCI POJEMNOSCI C KONDENSATORA DEKADOWEGO
MIERZYMY POJEMNOSC
KONDENSATORW .
A) POJEDYNCZYCH
B) LACZONYCH SZEREGOWO ( DWA DOWOLNE KONDENSATORY)
C) LACZONYCH RWNOLEGLE (DWA DOWOLNE KONDENSATORY)
3.ZAPISUJEMY WYNIKI W TABELI . OBLICZAMY WARTOSC SREDNIA KONDENSATORW .
4. WYZNACZAMY BLAD POMIARU POJEMNOSCI KAZDEGO Z KONDENSATORW I UKLADW
KONDENSATORW SPOSOBEM DOSWIADCZALNYM
AD.3
WARTOSCI SREDNIE DLA POSZCZEGLNYCH KONDENSATORW
.
AD4.
WYZNACZANIE BLEDU POJEMNOSCI KONDENSATORW . ZMIENIAMY POJEMNOSC
KONDENSATORA DEKADOWEGO C TAK , ABY ZNALEZDZ NAJMNIEJSZA WARTOSC ZMIANY
POJEMNOSCI , PRZY KTREJ STWIERDZAMY ZAUWAZALNA ZMIANE NATEZENIA DZWIEKU
W SLUCHAWKACH . ZNALEZIONA WARTOSC RWNA JEST BLEDOWI POMIARU NIEZNANEJ
POJEMNOSCI .
WARTOSCI KONDENSATORW I UKLADW KONDENSATORW .
WNIOSKI:
DOSWIADCZENIE POLEGAJACE NA WYZNACZENIU DOSWIADCZALNIE POJEMNOSCI
KONDENSATORW METODA MOSTKA WHEATSTONE'A POTWIERDZILO TEZE , ZE
POPRZEZ REGULACJE POJEMNOSCI KONDENSATORA DEKADOWEGO DOPROWADZAMY DO
SYTUACJI PODCZAS KTREJ PRZEZ SLUCHAWKI NIE PLYNIE PRAD(LUB NATEZENIE
PRADU JEST MALE ). WWCZAS NIEZNANA WARTOSC POJEMNOSCI KONDENSATORA JEST
RWNA POJEMNOSCI KONDENSATORA DEKADOWEGO . KAZDY POMIAR WARTOSCI
KONDENSATORW BYL OBARCZONY PEWNYM BLEDEM .BLEDY TE MOGA WYNIKAC Z
NIEDOSKONALOSCI NARZADU SLUCHU JAKIM JEST UCHO LUDZKIE . BLEDY POMIARU
ZOSTALY WYZNACZONE DOSWIADCZALNIE . METODA WYZNACZENIA BLEDW POMIARU
ZOSTALA OPISANA W PUNKCIE AD4.