Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
139
Description
The 1336 PLUS is a microprocessor based AC drive that provides a
PWM adjustable frequency and voltage output for exceptional control
of motor speed and torque. The output can be tuned to provide opti-
mum performance under a wide variety of load conditions.
Contents
Description
Page
Conformity to Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Standard Products Program . . . . . . . . . . . . . . . . . . . . . . . . . 140
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Required Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Factory Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
User Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Configured Drives Program. . . . . . . . . . . . . . . . . . . . . . . . . . 155
Configured Catalog Number Description . . . . . . . . . . . . . . . 156
Configured Product Selection. . . . . . . . . . . . . . . . . . . . . . . . 157
Factory Installed Options . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
Worst Case Enclosure Dimensions . . . . . . . . . . . . . . . . . . . 177
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
140
Allen-Bradley
Conformity to Standards
The 1336 PLUS conforms to the following standards:
Standard Products Program
This program includes standard 1336 PLUS drives rated from 0.37-
448 kW (0.5-600 HP). Drive mounting is available as Open, IP20
(NEMA Type 1), IP65 (NEMA Type 4) or IP54 (NEMA Type 12).
There is a limited offering of factory mounted options along with a
larger offering of option kits for user installation. The 1336 PLUS can
also be used with DriveTools32™ Suite, a family of software prod-
ucts that let you program, monitor and troubleshoot the drive. All
products in this program are pre-defined and not generally subject to
modification. To create custom drive packages based on specific
needs, refer to “Configured Drives Program” on page 155.
Standard
Configured
Option Types P & Q
Remaining Options
UL Listed
✔
✔
guidelines
CSA Certified (C-UL)
✔
✔
CE Conformity
✔
IEC Classified
✔
✔
Consult A-B
C-tick
✔
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
141
Product Selection
1336 PLUS Drive Catalog Number Explanation
➊
G Frame Standard Drives in enclosed construction are supplied through the
Configured Drives Program
and will have an “A” suffix after the HP rating.
➋
D through G Frame drives in IP 65 (NEMA Type 4) and IP 54 (NEMA Type 12) configurations are
supplied through the Configured Drives Program.
1336S
First Position
Bulletin Number
BR
Second Position
Voltage
Letter
Voltages
AQ
200-240V AC or
310V DC
BR
380-480VAC or
513-620V DC
CW
500-600V AC or
775V DC
A
200-240V AC
B
380-480V AC
BP
380-480V AC
(F Frame)
BPR 380-480V AC
(F Frame)
Roll-In Style
BX
Special Rating
C
500-600V AC
Q
310V DC
R
513-620V DC
RX
Special Rating
W
775V DC
F30
Third Position
Nominal HP Rating
Code kW (HP)
F05
0.37 (0.5)
F07
0.56 (0.75)
F10
0.75 (1)
F15
1.2 (1.5)
F20
1.5 (2)
F30
2.2 (3)
F50
3.7 (5)
F75
5.5 (7.5)
F100 7.5 (10)
007
5.5 (7.5)
010
7.5 (10)
015
11 (15)
020
15 (20)
025
18.5 (25)
030
22 (30)
040
30 (40)
050
37 (50)
060
45 (60)
075
56 (75)
100
75 (100)
125
93 (125)
150
112 (150)
200
149 (200)
250
187 (250)
➊
300
224 (300)
➊
350
261 (350)
➊
400
298 (400)
➊
450
336 (450)
➊
500
373 (500)
➊
600
448 (600)
➊
AA
Fourth Position
Enclosure Type
Code Type
AA
IP 20 (NEMA 1)
AE
IP 20 (NEMA 1)/
EMC
AF
IP 65 (NEMA 4)
➋
AJ
IP 54 (NEMA 12)
➋
AN
IP 00 (Open)
EN4
Fifth Position
Language
Code Language
EN3 English/English V3.04
EN4 English/English V4.xx
FR3 English/French V3.04
FR4 English/French V4.xx
DE3 English/German V3.04
DE4 English/German V4.xx
IT3
English/Italian V3.04
IT4
English/Italian V4.xx
ES3 English/Spanish V3.04
ES4 English/Spanish V4.xx
MODS
Sixth Position
Options
Code Description
Human Interface Module, IP 20 (NEMA Type 1)
HAB Blank - No Functionality
HAP Programmer Only
HA1 Programmer/Controller w/Analog Pot
HA2 Programmer/Controller w/Digital Pot
Human Interface Module, IP65/54 (NEMA Type 4/12)
HJP Programmer Only
HJ2
Programmer/Controller w/Digital Pot
Common Mode Choke
NCM No Common Mode Choke (F Frame)
CM
Internal Common Mode Choke
Code Description
Communication Options – B Frame & Up
GM1 Single Point Remote I/O
GM2 RS-232/422/485, DF1 & DH485
GM5 DeviceNet
GM6 Enhanced DeviceNet
Control Interface Options
L4
TTL Contact
L4E
TTL Contact & Encoder Feedback
L5
24V AC/DC
L5E
24V AC/DC & Encoder Feedback
L6
115V AC
L6E
115V AC & Encoder Feedback
or
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
142
Allen-Bradley
200-240VAC Input, Constant/Variable Torque Drives & Enclosures
➊
A Language Module must be specified with each drive. See page 144 for choices. All Language Modules will now include a firmware reference in the catalog number.
➋
At least one of either a Control Interface, Human Interface or Communication Board Option will be required to make the drive functional. The chosen option(s)
may be ordered factory installed (if available) or as add-on kits.
➌
Drive Rating is based on nominal voltage of 240 volts and carrier frequency of 4 khz at altitudes of 1000 meters or less. Refer to Publication 1336 PLUS-1.0 for
derating information.
➍
For Drives requiring CE/C-tick Conformance, use the -AE Enclosure Catalog Number and follow all the additional guidelines found on page 150 (CE/C-tick
Conformance).
➎
If a door mounted Human Interface Module is supplied, the Enclosure Rating is limited to IP 65 (NEMA and UL do not apply).
➏
See Configured Drives information on page 157 of this price guide.
1336S –
A030-AA
–
EN4
–
L6
–
HA1
–
GM1
Bulletin Number
Rating-Enclosure
(must be specified)
Language Module
(must be specified)
➊
Control Interface
(optional)
➋
Human Interface
(optional)
➋
Communication
Option
(optional)
➋
Frame
Nominal Drive Rating
➌
IP 00 (Open)
No Enclosure
IP 20 (NEMA Type 1) General
Purpose
IP 65 (NEMA Type 4)
Resist Water, Dust
IP 54 (NEMA Type 12)
Industrial Use
Output
Amps
CT
kW (HP)
VT
kW (HP)
Code
➊
❋
Code
➊➍
❋
Code
➊➎
❋
Code
➊
❋
A1
2.3
3.0
4.5
0.37 (0.5)
0.56 (0.75)
0.75 (1)
0.37 (0.5)
0.56 (0.75)
0.75 (1)
AQF05-AN
AQF07-AN
AQF10-AN
AQF05-AA/AE
AQF07-AA/AE
AQF10-AA/AE
AQF05-AF
AQF07-AF
AQF10-AF
AQF05-AJ
AQF07-AJ
AQF10-AJ
A2
6.0
8.0
1.2 (1.5)
1.5 (2)
1.2 (1.5)
1.5 (2)
AQF15-AN
AQF20-AN
AQF15-AA/AE
AQF20-AA/AE
AQF15-AF
AQF20-AF
AQF15-AJ
AQF20-AJ
A3
12.0
18.0
2.2 (3)
3.7 (5)
2.2 (3)
3.7 (5)
AQF30-AN
AQF50-AN
AQF30-AA/AE
AQF50-AA/AE
AQF30-AF
AQF50-AF
AQF30-AJ
AQF50-AJ
B1
27.0
5.5 (7.5)
5.5 (7.5)
A007-AN
A007-AA/AE
A007-AF
A007-AJ
B2
34.0
48.0
7.5 (10)
11 (15)
7.5 (10)
11 (15)
A010-AN
A015-AN
A010-AA/AE
A015-AA/AE
A010-AF
A015-AF
A010-AJ
A015-AJ
C
65.0
77.0
80.0
15 (20)
18.5 (25)
22 (30)
15 (20)
18.5 (25)
22 (30)
A020-AN
A025-AN
A030-AN
A020-AA/AE
A025-AA/AE
A030-AA/AE
A020-AF
A025-AF
A030-AF
A020-AJ
A025-AJ
A030-AJ
D
120.0
150.0
180.0
30 (40)
37 (50)
45 (60)
30 (40)
37 (50)
45 (60)
A040-AN
A050-AN
A060-AN
A040-AA/AE
A050-AA/AE
A060-AA/AE
Not Available
➏
E
240.0
291.0
325.0
56 (75)
75 (100)
93 (125)
56 (75)
75 (100)
93 (125)
A075-AN
A100-AN
A125-AN
A075-AA/AE
A100-AA/AE
A125-AA/AE
Not Available
➏
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
143
380-480VAC Input, Constant/Variable Torque Drives & Enclosures
➊
A Language Module must be specified with each drive. See page 144 for choices. All Language Modules will now include a firmware reference in the catalog number.
➋
At least one of either a Control Interface, Human Interface or Communication Board Option will be required to make the drive functional. The chosen option(s)
may be ordered factory installed (if available) or as add-on kits.
➌
Drive Rating is based on nominal voltage of 480V and carrier frequency of 4 kHz (D Frame and smaller) or 2 kHz (E Frame and larger) at altitudes of 1000 meters
or less. Refer to Publication 1336 PLUS-1.0 for derating information.
➍
For Drives requiring CE/C-tick Conformance, use the -AE Enclosure Catalog Number and follow all the additional guidelines found on page 150 (CE/C-tick
Conformance).
➎
If a Door Mounted Human Interface Module is supplied, the Enclosure Rating is limited to IP65 (NEMA and UL do not apply).
➏
See Configured Drives information on pages 158 and 159 of this price guide.
➐
VT Ratings apply to 460V input only. Refer to the back cover for complete rating information.
➑
A “Common Mode Choke” option (-CM) or “No Common Mode Choke” option (-NCM) must be specified with each F Frame Drive.
❾
These units include as standard an integral EMC filter.
1336S – B075-AA –
EN4
–
CM
– L6 – HA1 – GM1
Bulletin Number
Rating-Enclosure
(must be specified)
Language Module
(must be specified)
➊
Common Mode Choke
(must be specified with
any F Frame drive)
➑
Control
Interface
(optional)
Human
Interface
(optional)
Communication
Option
(optional)
Frame
Drive Rating
➌
IP00 (Open)
No Enclosure
IP 20 (NEMA Type 1)
General Purpose
IP 20 (NEMA Type 1)
CE/C-tick Conformance
IP65 (NEMA Type 4)
Resist Water, Dust
IP 54 (NEMA Type 12)
Industrial Use
Constant Torque Variable Torque
➐
Out
Amps kW (HP)
Out
Amps kW (HP)
Code
➊
❋
Code
➊
❋
Code
➊➍
❋
Code
➊➎
❋
Code
➊
❋
A1
1.1
1.6
2.1
2.8
0.37 (0.5)
0.56
(0.75)
0.75 (1)
1.2 (1.5)
1.2
1.7
2.3
3.0
0.37 (0.5)
0.56 (0.75)
0.75 (1)
1.2 (1.5)
BRF05-AN
BRF07-AN
BRF10-AN
BRF15-AN
BRF05-AA
BRF07-AA
BRF10-AA
BRF15-AA
BRF05-AE
BRF07-AE
BRF10-AE
BRF15-AE
BRF05-AF
BRF07-AF
BRF10-AF
BRF15-AF
BRF05-AJ
BRF07-AJ
BRF10-AJ
BRF15-AJ
A2
3.8
5.3
1.5 (2)
2.2 (3)
4.0
6.0
1.5 (2)
2.2 (3)
BRF20-AN
BRF30-AN
BRF20-AA
BRF30-AA
BRF20-AE
BRF30-AE
BRF20-AF
BRF30-AF
BRF20-AJ
BRF30-AJ
A3
8.4
3.7 (5)
9.0
3.7 (5)
BRF50-AN
BRF50-AA
BRF50-AE
BRF50-AF
BRF50-AJ
A4
14.0
17.5
5.5 (7.5)
7.5 (10)
17.5
25.0
7.5 (10)
11 (15)
BRF75-AN
BRF100-AN
BRF75-AA
BRF100-AA
BRF75-AE
BRF100-AE
BRF75-AF
BRF100-AF
BRF75-AJ
BRF100-AJ
B1
12.5
16.1
24.2
5.5 (7.5)
7.5 (10)
11 (15)
14.0
21.0
27.0
7.5 (10)
11 (15)
15 (20)
B007-AN
B010-AN
B015-AN
B007-AA
B010-AA
B015-AA
B007-AE
B010-AE
B015-AE
B007-AF
B010-AF
B015-AF
B007-AJ
B010-AJ
B015-AJ
B2
31.0
39.0
45.0
15 (20)
18.5 (25)
22 (30)
34.0
42.0
48.0
18.5 (25)
22 (30)
22 (30)
B020-AN
B025-AN
B030-AN
B020-AA
B025-AA
B030-AA
B020-AE
B025-AE
B030-AE
B020-AF
B025-AF
B030-AF
B020-AJ
B025-AJ
B030-AJ
C
59.0
60.0
75.0
77.0
30 (40)
30 (40)
37 (50)
45 (60)
59.0
65.0
75.0
77.0
30 (40)
37 (50)
45 (60)
45 (60)
BX040-AN
B040-AN
B050-AN
BX060-AN
BX040-AA
B040-AA
B050-AA
BX060-AA
BX040-AE
B040-AE
B050-AE
BX060-AE
BX040-AF
B040-AF
B050-AF
BX060-AF
BX040-AJ
B040-AJ
B050-AJ
BX060-AJ
D
85.0
106.0
138.0
173.0
180.0
45 (60)
56 (75)
75 (100)
93 (125)
112 (150)
96.0
120.0
150.0
180.0
180.0
56 (75)
75 (100)
93 (125)
112 (150)
112 (150)
B060-AN
B075-AN
B100-AN
B125-AN
BX150-AN
B060-AA
B075-AA
B100-AA
B125-AA
BX150-AA
B060-AE
B075-AE
B100-AE
B125-AE
BX150-AE
Not Available
➏
E
199.0
263.0
325.0
112 (150)
149 (200)
187 (250)
240.0
292.0
325.0
149 (200)
187 (250)
187 (250)
B150-AN
B200-AN
B250-AN
B150-AA
B200-AA
B250-AA
B150-AE
B200-AE
B250-AE
Not Available
➏
F
325.0
360.0
425.0
475.0
187 (250)
224 (300)
261 (350)
298 (400)
360.0
425.0
475.0
532.0
224 (300)
261 (350)
298 (400)
336 (450)
BP250-AN
➑
BP300-AN
➑
BP350-AN
➑
BP400-AN
➑
BP250-AA
➑
BP300-AA
➑
BP350-AA
➑
BP400-AA
➑
BP250-AE
➑❾
BP300-AE
➑❾
BP350-AE
➑❾
BP400-AE
➑❾
Not Available
➏
532.0
336 (450) 532.0 336 (450)
BP450-AN
➑
BP450-AA
➑
BP450-AE
➑❾
Not Available
Not Available
G
325.0
360.0
425.0
475.0
187 (250)
224 (300)
261 (350)
298 (400)
360.0
425.0
475.0
525.0
224 (300)
261 (350)
298 (400)
336 (450)
BX250-AN
B300-AN
B350-AN
B400-AN
BX250A-AA
B300A-AA
B350A-AA
B400A-AA
BX250A-AE
❾
B300A-AE
❾
B350A-AE
❾
B400A-AE
❾
Not Available
➏
525.0
590.0
670.0
336 (450)
373 (500)
448 (600)
590.0
670.0
670.0
373 (500)
448 (600)
448 (600)
B450-AN
B500-AN
B600-AN
B450A-AA
B500A-AA
B600A-AA
B450A-AE
❾
B500A-AE
❾
B600A-AE
❾
Not Available
Not Available
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
144
Allen-Bradley
500-600VAC Input, Constant/Variable Torque Drives & Enclosures
➊
A Language Module must be specified with each drive. See page 144 for choices. All Language Modules will now include a firmware reference in the catalog number.
➋
At least one of either a Control Interface, Human Interface or Communication Board Option will be required to make the drive functional. The chosen option(s)
may be ordered factory installed (if available) or as add-on kits.
➌
Drive Rating is based on nominal voltage of 600V and carrier frequency of 4 kHz (45 kW/60 HP and below) or 2 kHz (56 kW/75 HP and above) at altitudes of 1000
meters or less. Refer to Publication 1336 PLUS-1.0 for derating information.
➍
If a Door Mounted Human Interface Module is supplied, the Enclosure Rating is limited to IP65 (NEMA and UL do not apply).
➎
See Configured Drives information on pages 158 and 159 of this price guide.
Required Factory Installed Option
Language Modules — Factory Installed
(Select One)
Common Mode Choke for F Frame Drives — Factory Installed
(Select One)
1336S – C075-AA –
FR4
–
L6
–
HA1
–
GM1
Bulletin Number
Rating-Enclosure
(must be specified)
Language Module
(must be specified)
➊
Control Interface
(optional)
➋
Human Interface
(optional)
➋
Communication
Option
(optional)
➋
Frame
Drive Rating
➌
IP00 (Open)
No Enclosure
IP 20 (NEMA Type 1)
General Purpose
IP65(NEMAType 4)
Resist Water, Dust
IP 54 (NEMA Type 12)
Industrial Use
Constant Torque
Variable Torque
Output
Amps
kW (HP)
Output
Amps
kW (HP)
Code
➊
❋
Code
➊
❋
Code
➊➍
❋
Code
➊
❋
A4
2.0
4.0
6.0
8.0
0.75 (1)
1.5 (2)
2.2 (3)
3.7 (5)
2.0
4.0
6.0
8.0
0.75 (1)
1.5 (2)
2.2 (3)
3.7 (5)
CWF10-AN
CWF20-AN
CWF30-AN
CWF50-AN
CWF10-AA
CWF20-AA
CWF30-AA
CWF50-AA
CWF10-AF
CWF20-AF
CWF30-AF
CWF50-AF
CWF10-AJ
CWF20-AJ
CWF30-AJ
CWF50-AJ
B1
10.0
12.0
5.5 (7.5)
7.5 (10)
10.0
12.0
5.5 (7.5)
7.5 (10)
C007-AN
C010-AN
C007-AA
C010-AA
C007-AF
C010-AF
C007-AJ
C010-AJ
B2
19.0
24.0
11 (15)
15 (20)
19.0
24.0
11 (15)
15 (20)
C015-AN
C020-AN
C015-AA
C020-AA
C015-AF
C020-AF
C015-AJ
C020-AJ
C
30.0
35.0
18.5 (25)
22 (30)
30.0
35.0
18.5 (25)
22 (30)
C025-AN
C030-AN
C025-AA
C030-AA
C025-AF
C030-AF
C025-AJ
C030-AJ
45.0
57.0
62.0
30 (40)
37 (50)
45 (60)
45.0
57.0
62.0
30 (40)
37 (50)
45 (60)
C040-AN
C050-AN
C060-AN
C040-AA
C050-AA
C060-AA
C040-AF
C050-AF
C060-AF
C040-AJ
C050-AJ
C060-AJ
D
85.0
109.0
138.0
56 (75)
75 (100)
93 (125)
85.0
109.0
138.0
56 (75)
75 (100)
93 (125)
C075-AN
C100-AN
C125-AN
C075-AA
C100-AA
C125-AA
Not Available
➎
E
158.0
252.0
284.0
300.0
112 (150)
149 (200)
187 (250)
224 (300)
158.0
252.0
284.0
300.0
112 (150)
149 (200)
187 (250)
224 (300)
C150-AN
C200-AN
C250-AN
CX300-AN
C150-AA
C200-AA
C250-AA
CX300-AA
Not Available
➎
G
300.0
350.0
400.0
224 (300)
261 (350)
298 (400)
300.0
350.0
400.0
224 (300)
261 (350)
298 (400)
C300-AN
C350-AN
C400-AN
C300A-AA
C350A-AA
C400A-AA
Not Available
➎
450.0
500.0
600.0
336 (450)
373 (500)
448 (600)
450.0
500.0
600.0
336 (450)
373 (500)
448 (600)
C450-AN
C500-AN
C600-AN
C450A-AA
C500A-AA
C600A-AA
Not Available
Not Available
Description
Used with . . .
Option Code
(Firmware 3.04)
Option Code
(Firmware 4.xx)
❋
English/English
All Drives
-EN3
-EN4
English/French
All Drives
-FR3
-FR4
English/German
All Drives
-DE3
-DE4
English/Italian
All Drives
-IT3
-IT4
English/Spanish
All Drives
-ES3
-ES4
Description
Used With . . .
Option Code
❋
No Common Mode Choke
All F Frame
Drives
-NCM
Internal Common Mode Choke — Installed
-CM
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
145
Factory Installed Options
Common Mode Choke for G Frame Drives — Factory Installed
Interface Options
Coating of Drive Printed Circuit Boards
User Installed Options
Control Interface Kits
Language Module Kit
➊
For a more functionally complete description of each option, refer to Publication 1336 PLUS-1.0.
➋
A maximum of one communication option may be ordered factory installed.
➌
This option may be used on an IP65 or IP66 rated enclosure to meet watertight indoor applications.
➍
All F Frame Drives require that either option -NCM or -CM be specified.
Description
➊
Used With . . .
Option Code
❋
Internal Common Mode Choke — Installed
G Frame Drives
-CM
Description
➊
Used With . . .
Option Code
❋
Communication Options
Single Point RI0
RS232/422/485, DF1 & DH485 Protocol
DeviceNet
Enhanced DeviceNet
Frames B, C, D,
E, F & G
-GM1
➋
-GM2
➋
-GM5
➋
-GM6
➋
Control Interface
Contact Closure
+24VAC/DC
115VAC
All Drives
-L4
-L5
-L6
Control Interface w/ Encoder Feedback
Contact Closure
+24VAC/DC
115VAC
All Drives
-L4E
-L5E
-L6E
Human Interface Module, IP 20 (NEMA Type 1)
Blank — No Functionality
Programmer Only
Programmer/Controller with Analog Pot
Programmer/Controller with Digital Pot
IP 00 (Open) and
IP 20 (NEMA
Type 1) Drives
-HAB
-HAP
-HA1
-HA2
Human Interface Module, IP65
Programmer Only
Programmer/Controller with Digital Pot
IP 65 or IP 54
(NEMA Type 12)
Drives
-HJP
➌
-HJ2
➌
Description
Used With . . .
Option Code
❋
Conformal Coating of drive printed circuit boards
for protection against dirt, moisture, fungus and
corrosion.
A-B Frames
C Frame
D Frame
E-G Frames
All Drives
-MX3
Description
➊
Used with . . .
Catalog No.
(Loose Kit)
❋
Contact Closure
All 1336S Drives
1336-L4
24VAC/DC
All 1336S Drives
1336-L5
115VAC
All 1336S Drives
1336-L6
Contact Closure & Encoder Feedback
All 1336S Drives
1336-L4E
24VAC/DC and Encoder Feedback
All 1336S Drives
1336-L5E
115VAC and Encoder Feedback
All 1336S Drives
1336-L6E
Description
➊
Used with . . .
Catalog Number
(loose kit-FRN 3.04)
Catalog Number
(loose kit-FRN 4.xx)
❋
English/English
All 1336S Drives
1336S-EN3
1336S-EN4
English/French
All 1336S Drives
1336S-FR3
1336S-FR4
English/German
All 1336S Drives
1336S-DE3
1336S-DE4
English/Italian
All 1336S Drives
1336S-IT3
1336S-IT4
English/Spanish
All 1336S Drives
1336S-ES3
1336S-ES4
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
146
Allen-Bradley
Dynamic Brake, Complete Kits
Dynamic Brake, Chopper Only Kits
Description
Brake Rating
Catalog Number
(Loose Kit)
❋
For 200-240VAC Drives
3.7 kW (5 HP) Max.
1336-MOD-KA005
7.5 kW (10 HP) Max.
1336-MOD-KA010
For 380-480VAC Drives
3.7 kW (5 HP) Max.
1336-MOD-KB005
7.5 kW (10 HP) Max.
1336-MOD-KB010
37 kW (50 HP) Max.
1336-MOD-KB050
For 500-600VAC Drives
3.7 kW (5 HP) Max.
1336-MOD-KC005
7.5 kW (10 HP) Max.
1336-MOD-KC010
37 kW (50 HP) Max.
1336-MOD-KC050
Description
Chopper Rating
Catalog Number
(Loose Kit)
❋
200-240VAC
18A
1336-WA018
70A
1336-WA070
115A
1336-WA115
380-480VAC
9A
1336-WB009
35A
1336-WB035
110A
1336-WB110
500-600VAC
9A
1336-WC009
35A
1336-WC035
85A
1336-WC085
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
147
Gasket and Enclosure Kits
➊
For a more functionally complete description of each option refer to Publication 1336 PLUS-1.0.
➋
Multiple brake kits may be utilized together to obtain higher kW (HP) ratings. Refer to Publication
1336-5.64 for guidance.
➌
Multiple chopper kits may be utilized together to obtain higher ratings. Refer to Publication 1336-
5.65 for guidance.
➍
Use of a Door Mounted Human Interface Module on these Enclosures will void the NEMA Type
4 Rating.
➎
Using this kit with a 500-600V drive will not make the drive CE compliant. While these kits can
offer EMC improvements, CE tests do not currently exist for equipment above 480V.
Junction Box, Complete Kit
DriveTools32 Suite
Description
Used with
Frame . . .
Catalog Number
(Loose Kit)
❋
200-240V
380-480V
500-600V
Gasket Kits for mounting
1336S Drives in User
Supplied IP 54 or 65
(NEMAType12or4) Encl.
A1, A2, A3
A4
B
C
1336-RF3
—
1336-RF4
1336-RF5
1336-RF3
1336-RF2
1336-RF4
1336-RF5
—
1336-RF2
1336-RF4
1336-RF5
Gasket Kits for mounting
1336S Drives in User
Supplied IP 54 (NEMA
Type12) Enclosures
D
E
1336-RF6
1336-RF7
1336-RF6
1336-RF7
1336-RF6
1336-RF7
Enclosure Kits
IP20 (NEMAType1)
A1, A2, A3
A4
B
C
D
E
1336S-AA3
—
1336S-AA4
1336S-AA5
1336S-AA6
1336S-AA7
1336S-AA3
1336S-AA2
1336S-AA4
1336S-AA5
1336S-AA6
1336S-AA7
—
1336S-AA2
1336S-AA4
1336S-AA5
1336S-AA6
1336S-AA7
Enclosure Kits
IP20 (NEMAType1) for
CE/C-tick Conformance
A1, A2, A3
A4
B
C
D
E
1336S-AE3
1336S-AE2
1336S-AE4
1336S-AE5
1336S-AE6
1336S-AE7
1336S-AE3
1336S-AE2
1336S-AE4
1336S-AE5
1336S-AE6
1336S-AE7
—
—
1336S-AE4
➎
1336S-AE5
➎
1336S-AE6
➎
1336S-AE7
➎
Enclosure Kits
IP 54 (NEMA Type12)
A1, A2, A3
A4
B1
B2
C
1336S-AJA3
—
1336S-AJB1A
1336S-AJB2A
1336S-AJCA
1336S-AJA3
1336S-AJA4B
1336S-AJB1B
1336S-AJB2B
1336S-AJCB
—
1336S-AJA4C
1336S-AJB1C
1336S-AJB2C
1336S-AJCC
Enclosure Kits
IP 65 (NEMA Type4)
➍
A1, A2, A3
A4
B1
B2
C
1336S-AFA3
—
1336S-AFB1A
1336S-AFB2A
1336S-AFCA
1336S-AFA3
1336S-AFA4B
1336S-AFB1B
1336S-AFB2B
1336S-AFCB
—
1336S-AFA4C
1336S-AFB1C
1336S-AFB2C
1336S-AFCC
Description
Used with Enclosure
Designation . . .
Catalog Number
Loose Kit)
❋
For all B Frame Drives
IP 20 (NEMA Type 1)
-AA
1336-JBBA
-AE
1336-JBBE
For all C Frame Drives
IP 20 (NEMA Type 1)
-AA
1336-JBCA
-AE
1336-JBCE
Description
DriveTools32 Software
See A-B publication 9303-3.0 for ordering/pricing information
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
148
Allen-Bradley
Human Interface Module (HIM) Kits — User Installed
Graphic Programming Terminal — User Installed or Hand-Held
➊
For a more functionally complete description of each option refer to Publication 1336 PLUS-1.0.
➋
Requires an Option Cable to be functional. These units are not acceptable for NEMA Type 4 door
mounting or UL Type 4X outdoor duty.
Description
➊
Used with . . .
Catalog Number
(Loose Kit)
❋
IP 20 (NEMA Type 1) HIM
Blank — No Functionality
Programmer Only
Programmer/Controller w/Analog Speed Pot.
Programmer/Controller w/Digital Speed Pot.
All Open Chassis and
IP 20 (NEMA Type 1)
Drive Ratings
1201-HAB
1201-HAP
1201-HA1
1201-HA2
IP 65 (NEMAType12/ULType 4X-Indoor) HIM
Programmer Only
Programmer/Controller w/Digital Speed Pot.
IP 66 (NEMA Type 12/
UL Type 4X Indoor)
Enclosures
1201-HJP
➋
1201-HJ2
➋
Option Cable Kit — Connect to HIM Cradle Port
0.33 Meters (1.1 Feet)
1 Meter (3.3 Feet)
3 Meter (9.8 Feet)
9 Meter (29.5 Feet)
All HIMs not mounted
on the drive chassis
1202-H03
1202-H10
1202-H30
1202-H90
Option Cable Kit — Connect to Comm. Port
0.33 Meters (1.1 Feet)
1 Meter (3.3 Feet)
3 Meter (9.8 Feet)
9 Meter (29.5 Feet)
All HIMs not mounted
on the drive chassis
1202-C03
1202-C10
1202-C30
1202-C90
IP 20 (NEMA Type 1) Door Mount Bezel Kit
User Supplied IP 20
(NEMA Type 1) Enclo-
sures and HIM
1201-DMA
HIM
HIM
Cradle
Option Cable
1202-H03/H10/H30/H90
JOG
ESC
SEL
Description
➊
Used with . . .
Catalog Number
(Loose Kit)
❋
NEMA Type 1/12 (Enhanced)
Programmer Only
Programmer/Run Time Functions
All Open Chassis and
IP 20 & 54 (NEMA
Type 1 & 12) 1336S
Drive Ratings
1201-HJPE
1201-HJ3E
Hand-Held (Enhanced)
Programmer Only
Programmer/Run Time Functions
All 1336S Drive Rat-
ings
1201-HHPE
1201-HH3E
Communication
Port(s)
GPT
HIM
Port
F1
F2
F3
F4
Cable
Included
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
149
Communication Option Kits
➊
For a more functionally complete description of each option refer to Publication 1336 PLUS-1.0.
➋
Requires a Communication Option Cable (1202-C03/C10/C30/C90) to be functional. These units
are not acceptable for NEMA Type 4 door mounting or UL Type 4X outdoor duty.
➌
Each Flex I/O SCANport Module requires (1) 1203-FB1 and (1) 1203-FM1.
➍
Adapter is programmed/configured with Windows
HyperTerminal via RS-232 using the 1203-
SFC cable, (purchased separately) or using a compatible network specific software tool.
Description
➊
Used with . . .
Catalog Number
(Loose Kit)
❋
Remote Mounted (DIN Rail) — 115VAC
Requires 115VAC power supply
Single Point RIO
RS232/422/485, DF1 and DH485 Protocol
All Drive Ratings
1203-GD1
➋
1203-GD2
➋
Remote Mounted (DIN Rail) — 24V DC
Requires 24VDC power supply
Single Point RIO
RS232/422/485, DF1 and DH485 Protocol
DeviceNet
Enhanced DeviceNet
All Drive Ratings
1203-GK1
➋
1203-GK2
➋
1203-GK5
➋
1203-GU6
➋➍
Drive Mounted and Drive Powered
(with loose snap-in cradle/blank plate)
Single Point RIO
RS232/422/485, DF1 and DH485 Protocol
DeviceNet
Enhanced DeviceNet
B Frame & Up —
Adapter 6
1336-GM1
1336-GM2
1336-GM5
1336-GM6
ControlNet™ to SCANport Adapter
Remote Mounted (DIN Rail) — 24V DC
Requires 24VDC power supply
All Drive Ratings
1203-CN1
➋➍
Smart Serial to SCANport Adapter
Includes 1203-SFC and 1202-C10 Cables
All Drive Ratings
1203-SSS
Flex™ I/O SCANport Module
➌
Flex I/O Terminal Base
Flex I/O Module
Each FM1/FB1 combination provides a con-
nection for up to 2 drive products.
All Drive Ratings
1203-FB1
➌
1203-FM1
➋➌
SLC™ Communication Module
(SLC 500 to SCANport Module)
Provides a connection for up to 3 drive prod-
ucts.
All Drive Ratings
1203-SM1
➋
Serial Flash Cable
Connects CN1, GU6 and SSS to a
computer RS-232 port for adapter
programming and for DriveTools32 &
DriveExplorer™ serial interface.
All Drive Ratings
1203-SFC
Communication Option Cable Kit
0.33 Meters (1.1 Feet)
1 Meter (3.3 Feet)
3 Meter (9.8 Feet)
9 Meter (29.5 Feet)
All External Commu-
nication Options
Listed Above
1202-C03
1202-C10
1202-C30
1202-C90
SCANport™ Expander Option
One to Two Port Expander Module
One to Four Port Expander Module
One to Two Port Splitter Cable
All Drive Ratings
1203-SG2
1203-SG4
1203-S03
120/240V AC
Input
DIN Rail
Communication Module
RIO
SCANport
Comm
Status
to PLC
Option Cable to Drive
(1202-C03/C10/C30/C90)
GD1/GD2 – Typical Configuration
Input Voltage
Mounts to
Drive Main
Control Board
GM1/GM2, GM5/GM6 – Typical Configuration
to PLC
Flex Modules
FB1 and FM1 – Typical Configuration
SLC
SM1 – Typical Configuration
CN1 – Typical Configuration
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
150
Allen-Bradley
CE/C-Tick Conformance
Conformance To CE requires all of the following:
•
A Standard 1336 PLUS Drive with the “CE” mark on the data
nameplate.
•
A factory installed IP 20 (NEMA Type 1) Enclosure Option -AE
or field installed Enclosure Option AE2, AE3, AE4 or AE5 (see
page 147).
•
Installation per the 1336 PLUS User Manual, pub. 1336
PLUS-5.0.
•
An EMC Filter from the table below.
➊
If the “AE” style enclosure is specified on an F or G Frame Drive, the EMC filter is already included
in the package.
Line Reactors, Isolation Transformers & Common Mode Chokes
(For Remote User Mounting)
Specifications
Line Reactors
Iron core, 3% or 5% impedance, 600V, Class H insulation, 115 degree
C rise, copper wound, 50/60 Hz., terminal blocks (80A and below),
copper box lugs (160A and above), UL, CSA.
Isolation Transformers
230V/230V, 460V/460V or 575V/575V Delta primary/Wye second-
ary, Class H insulation, 150 degree C rise, aluminum wound, 60 Hz.,
±
5% taps, (1) N.C. thermostat per coil, UL, CSA.
Filter Catalog Number
Used with . . .
❋
1336-RFB-7-A
1336S-AQF05 - AQF10 & 1336S-BRF05 - BRF20
1336-RFB-16-A
1336S-AQF15 - AQF20 & 1336S-BRF30 - BRF50
1336-RFB-30-A
1336S-AQF30 - AQF50
1336-RFB-30-A4
1336S-BRF75 - BRF100
1336-RFB-27-B
1336S-A007 & 1336S-B007 - B015
1336-RFB-48-B
1336S-A010 - A015 & 1336S-B020 - B030
1336-RFB-80-C
1336S-A020 - A030 & 1336S-BX040 - BX060
1336-RFB-150-D
1336S-A040 - A050 & 1336S-B060 - B100
1336-RFB-180-D
1336S-A060 & 1336S-B125 - BX150
1336-RFB-340-E
1336S-A075 - A125 & 1336S-B150 - B250
1336-RFB-475-G
➊
1336S-BX250 - B350, 1336S-BP250 - BP350
1336-RFB-590-G
➊
1336S-B400 - B450, 1336S-BP400 - BP450
1336-RFB-670-G
➊
1336S-B500 - B600
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
151
Line Reactors
200-240VAC Input
380-480VAC Input
➊
Input Reactor Only.
➋
Input Reactor on G Frame Drives Only.
Drive Ratings
kW (HP)
Input or Output Line Reactor — 3% Impedance
Input or Output Line Reactor — 5% Impedance
IP 00 (Open Style)
IP 10 (NEMA Type 1)
IP 00 (Open Style)
IP 10 (NEMA Type 1)
Catalog Number
❋
Catalog Number
❋
Catalog Number
❋
Catalog Number
❋
0.37 (0.50)
0.56 (0.75)
0.75 (1)
1.2 (1.5)
1.5 (2)
1321-3R2-D
1321-3R4-A
1321-3R4-A
1321-3R8-A
1321-3R8-A
1321-3RA2-D
1321-3RA4-A
1321-3RA4-A
1321-3RA8-A
1321-3RA8-A
1321-3R2-A
1321-3R4-B
1321-3R4-B
1321-3R8-B
1321-3R8-B
1321-3RA2-A
1321-3RA4-B
1321-3RA4-B
1321-3RA8-B
1321-3RA8-B
2.2 (3)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
1321-3R12-A
1321-3R18-A
1321-3R25-A
1321-3R35-A
1321-3R45-A
1321-3RA12-A
1321-3RA18-A
1321-3RA25-A
1321-3RA35-A
1321-3RA45-A
1321-3R12-B
1321-3R18-B
1321-3R25-B
1321-3R35-B
1321-3R45-B
1321-3RA12-B
1321-3RA18-B
1321-3RA25-B
1321-3RA35-B
1321-3RA45-B
15 (20)
➊
15 (20)
18.5 (25)
22 (30)
30 (40)
1321-3R55-A
➊
1321-3R80-A
1321-3R80-A
1321-3R80-A
1321-3R130-A
1321-3RA55-A
➊
1321-3RA80-A
1321-3RA80-A
1321-3RA80-A
1321-3RA130-A
1321-3R55-B
➊
1321-3R80-B
1321-3R80-B
1321-3R80-B
1321-3R130-B
1321-3RA55-B
➊
1321-3RA80-B
1321-3RA80-B
1321-3RA80-B
1321-3RA130-B
37 (50)
45 (60)
56 (75)
75 (100)
93 (125)
1321-3R160-A
1321-3R200-A
1321-3R250-A
1321-3R320-A
1321-3R320-A
1321-3RA160-A
1321-3RA200-A
1321-3RA250-A
1321-3RA320-A
1321-3RA320-A
1321-3R160-B
1321-3R200-B
1321-3R250-B
1321-3R320-B
1321-3R320-B
1321-3RA160-B
1321-3RA200-B
1321-3RA250-B
1321-3RA320-B
1321-3RA320-B
Drive Ratings
kW (HP)
Input or Output Line Reactor — 3% Impedance
Input or Output Line Reactor — 5% Impedance
IP 00 (Open Style)
IP 10 (NEMA Type 1)
IP 00 (Open Style)
IP 10 (NEMA Type 1)
Catalog Number
❋
Catalog Number
❋
Catalog Number
❋
Catalog Number
❋
0.37 (0.50)
0.56 (0.75)
0.75 (1)
1.2 (1.5)
1.5 (2)
1321-3R2-B
1321-3R2-B
1321-3R2-A
1321-3R4-B
1321-3R4-B
1321-3RA2-B
1321-3RA2-B
1321-3RA2-A
1321-3RA4-B
1321-3RA4-B
1321-3R2-B
1321-3R2-B
1321-3R2-B
1321-3R4-C
1321-3R4-C
1321-3RA2-B
1321-3RA2-B
1321-3RA2-B
1321-3RA4-C
1321-3RA4-C
2.2 (3)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
1321-3R8-B
1321-3R8-B
1321-3R12-B
1321-3R18-B
1321-3R25-B
1321-3RA8-B
1321-3RA8-B
1321-3RA12-B
1321-3RA18-B
1321-3RA25-B
1321-3R8-C
1321-3R8-C
1321-3R12-C
1321-3R18-C
1321-3R25-C
1321-3RA8-C
1321-3RA8-C
1321-3RA12-C
1321-3RA18-C
1321-3RA25-C
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
1321-3R35-B
1321-3R35-B
1321-3R45-B
1321-3R55-B
1321-3R80-B
1321-3RA35-B
1321-3RA35-B
1321-3RA45-B
1321-3RA55-B
1321-3RA80-B
1321-3R35-C
1321-3R35-C
1321-3R45-C
1321-3R55-C
1321-3R80-C
1321-3RA35-C
1321-3RA35-C
1321-3RA45-C
1321-3RA55-C
1321-3RA80-C
45 (60)
56 (75)
75 (100)
93 (125)
112 (150)
1321-3R80-B
1321-3R100-B
1321-3R130-B
1321-3R160-B
1321-3R200-B
1321-3RA80-B
1321-3RA100-B
1321-3RA130-B
1321-3RA160-B
1321-3RA200-B
1321-3R80-C
1321-3R100-C
1321-3R130-C
1321-3R160-C
1321-3R200-C
1321-3RA80-C
1321-3RA100-C
1321-3RA130-C
1321-3RA160-C
1321-3RA200-C
149 (200)
187 (250)
224 (300)
261 (350)
➋
261 (350)
1321-3R250-B
1321-3R320-B
1321-3R400-B
1321-3R400-B
➋
1321-3R500-B
1321-3RA250-B
1321-3RA320-B
1321-3RA400-B
1321-3RA400-B
➋
1321-3RA500-B
1321-3R250-C
1321-3R320-C
1321-3R400-C
1321-3R400-C
➋
1321-3R500-C
1321-3RA250-C
1321-3RA320-C
1321-3RA400-C
1321-3RA400-C
➋
1321-3RA500-C
298 (400)
336 (450)
➋
336 (450)
373 (500)
448 (600)
1321-3R500-B
1321-3R500-B
➋
1321-3R600-B
1321-3R600-B
1321-3R750-B
1321-3RA500-B
1321-3RA500-B
➋
1321-3RA600-B
1321-3RA600-B
1321-3RA750-B
1321-3R500-C
1321-3R500-C
➋
1321-3R600-C
1321-3R600-C
1321-3R750-C
1321-3RA500-C
1321-3RA500-C
➋
1321-3RA600-C
1321-3RA600-C
1321-3RA750-C
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
152
Allen-Bradley
❋
Prices – Consult Sales Office or price list
Line Reactors
(continued)
500-600VAC Input
Common Mode Chokes
(External to Drive)
➊
Input Reactor Only.
➋
For a more functionally complete description of each option refer to Publication 1336 PLUS-1.0.
Drive Ratings
kW (HP)
Input or Output Line Reactor — 3% Impedance
Input or Output Line Reactor — 5% Impedance
IP 00 (Open Style)
IP 10 (NEMA Type 1)
IP 00 (Open Style)
IP 10 (NEMA Type 1)
Catalog Number
❋
Catalog Number
❋
Catalog Number
❋
Catalog Number
❋
0.75 (1)
1.5 (2)
2.2 (3)
3.7 (5)
5.5 (7.5)
1321-3R2-B
1321-3R4-C
1321-3R8-B
1321-3R8-B
1321-3R8-B
1321-3RA2-B
1321-3RA4-C
1321-3RA8-B
1321-3RA8-B
1321-3RA8-B
1321-3R2-C
1321-3R4-D
1321-3R8-C
1321-3R8-C
1321-3R8-C
1321-3RA2-C
1321-3RA4-D
1321-3RA8-C
1321-3RA8-C
1321-3RA8-C
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
1321-3R12-B
1321-3R18-B
1321-3R25-B
1321-3R25-B
1321-3R35-B
1321-3RA12-B
1321-3RA18-B
1321-3RA25-B
1321-3RA25-B
1321-3RA35-B
1321-3R12-C
1321-3R18-C
1321-3R25-C
1321-3R25-C
1321-3R35-C
1321-3RA12-C
1321-3RA18-C
1321-3RA25-C
1321-3RA25-C
1321-3RA35-C
30 (40)
37 (50)
45 (60)
56 (75)
75 (100)
1321-3R45-B
1321-3R55-B
1321-3R80-B
1321-3R80-B
1321-3R100-B
1321-3RA45-B
1321-3RA55-B
1321-3RA80-B
1321-3RA80-B
1321-3RA100-B
1321-3R45-C
1321-3R55-C
1321-3R80-C
1321-3R80-C
1321-3R100-C
1321-3RA45-C
1321-3RA55-C
1321-3RA80-C
1321-3RA80-C
1321-3RA100-C
93 (125)
112 (150)
149 (200)
➊
149 (200)
187 (250)
224 (300)
1321-3R130-B
1321-3R160-B
1321-3R200-B
➊
1321-3R250-B
1321-3R250-B
1321-3R320-B
1321-3RA130-B
1321-3RA160-B
1321-3RA200-B
➊
1321-3RA250-B
1321-3RA250-B
1321-3RA320-B
1321-3R130-C
1321-3R160-C
1321-3R200-C
➊
1321-3R250-C
1321-3R250-C
1321-3R320-C
1321-3RA130-C
1321-3RA160-C
1321-3RA200-C
➊
1321-3RA250-C
1321-3RA250-C
1321-3RA320-C
261 (350)
298 (400)
336 (450)
373 (500)
448 (600)
1321-3R400-B
1321-3R400-B
1321-3R500-B
1321-3R500-B
1321-3R600-B
1321-3RA400-B
1321-3RA400-B
1321-3RA500-B
1321-3RA500-B
1321-3RA600-B
1321-3R400-C
1321-3R400-C
1321-3R500-C
1321-3R500-C
1321-3R600-C
1321-3RA400-C
1321-3RA400-C
1321-3RA500-C
1321-3RA500-C
1321-3RA600-C
Description
➋
Used with . . .
Catalog Number
❋
Open Style, 1A
Communication and Signal Type
Cables
1321-M001
Open Style, 9A
(with Terminal Block)
All 1336 PLUS Drives Rated:
230V, 0.37-1.5 kW (0.5-2 HP)
480V, 0.37-3.7 kW (0.5-5 HP)
1321-M009
Open Style, 48A
All 1336 PLUS Drives Rated:
230V, 2.2-11 kW (3-15 HP)
480V, 5.5-22 kW (7.5-30 HP)
600V, 0.75-30 kW (1-40 HP)
1321-M048
Open Style, 180A
All 1336 PLUS Drives Rated:
230V, 15-45 kW (20-60 HP)
480V, 30-112 kW (40-X150 HP)
600V, 37-112 kW (50-150 HP)
1321-M180
Open Style, 670A
All 1336 PLUS Drives Rated:
230V, 56-93 kW (75-125 HP)
480V, 112-448 kW (150-600 HP)
600V, 149-448 kW (200-600 HP)
1321-M670
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
153
Isolation Transformers
Reflected Wave Reduction Device
Terminator
➊
For a more functionally complete description of each option refer to Publication 1204-1.0.
➋
Limited to motor cable lengths of 61 meters (200 feet).
Drive
Ratings
kW (HP)
230V Primary &
230V Secondary
460V Primary &
460V Secondary
575V Primary &
575V Secondary
IP 20 (NEMA Type 1)
IP 20 (NEMA Type 1)
IP 20 (NEMA Type 1)
Catalog
Number
❋
Catalog
Number
❋
Catalog
Number
❋
0.37 (0.50)
0.56 (0.75)
0.75 (1)
1.2 (1.5)
1.5 (2)
1321-3T005-AA
1321-3T005-AA
1321-3T005-AA
1321-3T005-AA
1321-3T005-AA
1321-3T005-BB
1321-3T005-BB
1321-3T005-BB
1321-3T005-BB
1321-3T005-BB
—
—
1321-3T005-CC
—
1321-3T005-CC
2.2 (3)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
1321-3T005-AA
1321-3T007-AA
1321-3T011-AA
1321-3T014-AA
1321-3T020-AA
1321-3T005-BB
1321-3T007-BB
1321-3T011-BB
1321-3T014-BB
1321-3T020-BB
1321-3T005-CC
1321-3T007-CC
1321-3T011-CC
1321-3T014-CC
1321-3T020-CC
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
1321-3T027-AA
1321-3T034-AA
1321-3T040-AA
1321-3T051-AA
1321-3T063-AA
1321-3T027-BB
1321-3T034-BB
1321-3T040-BB
1321-3T051-BB
1321-3T063-BB
1321-3T027-CC
1321-3T034-CC
1321-3T040-CC
1321-3T051-CC
1321-3T063-CC
45 (60)
56 (75)
75 (100)
93 (125)
112 (150)
1321-3T075-AA
1321-3T093-AA
1321-3T118-AA
1321-3T145-AA
—
1321-3T075-BB
1321-3T093-BB
1321-3T118-BB
1321-3T145-BB
1321-3T175-BB
1321-3T075-CC
1321-3T093-CC
1321-3T118-CC
1321-3T145-CC
1321-3T175-CC
149 (200)
187 (250)
224 (300)
261 (350)
298 (400)
—
—
—
—
—
1321-3T220-BB
1321-3T275-BB
1321-3T330-BB
1321-3T440-BB
1321-3T440-BB
1321-3T220-CC
1321-3T275-CC
1321-3T330-CC
1321-3T440-CC
1321-3T440-CC
336 (450)
373 (500)
448 (600)
—
—
—
1321-3T550-BB
1321-3T550-BB
1321-3T660-BB
1321-3T550-CC
1321-3T550-CC
1321-3T660-CC
Description
Used with . . .
Catalog Number
(Loose Kit)
❋
380-575VAC, 9A
IP 20 (NEMA Type 1)
0.37-3.7 kW (0.5-5 HP)
380-460V & 500-600V A Frame Drives
1204-RWR2-09-B
Description
➊
Used with . . .
Catalog Number
❋
IP 65 (NEMA Type 4x)
Connection Cable Included
0.75-3.7 kW (1-5 HP),
460V Drives
1204-TFA1
➋
2.2-448 kW (3-600 HP), 460
& 575V Drives
1204-TFB2
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
154
Allen-Bradley
Option Selection Reference Chart
Selected Option
Must Be Used With...
Can Not Be Used With...
AA
AE
AN
AF
AJ
—
CE Filter Kit
—
—
—
AE, AF, AN, AJ, HJ2, HJP
575V Drives, AA, AN, AF, AJ, HJ2, HJP
AE, AF, AA, AJ, HJ2, HJP
AA, AE, AJ, AN, HAB, HAP, HA1, HA2
AA, AE, AF, AN, HAB, HAP, HA1, HA2
C03, C10, C30, C90
HIM or Communication Option
—
CM
F & G Frame Drives Only
NCM, A-E Frame Drives
DE3
DE4
—
—
DE4, EN3, EN4, ES3, ES4, FR3, FR4, IT3, IT4
DE3, EN3, EN4, ES3, ES4, FR3, FR4, IT3, IT4
DMA
IP 20 (NEMA Type 1) HIM or Blank Insert
Drive packaging other than IP 20 (NEMA Type 1)
EN3
EN4
ES3
ES4
—
—
—
—
DE3, DE4, EN4, ES3, ES4, FR3, FR4, IT3, IT4
DE3, DE4, EN3, ES3, ES4, FR3, FR4, IT3, IT4
DE3, DE4, EN3, EN4, ES4, FR3, FR4, IT3, IT4
DE3, DE4, EN3, EN4, ES3, FR3, FR4, IT3, IT4
FB1
FM1
—
FM1
FB1, One of a C03, C10, C30 or C90
—
FR3
FR4
—
—
DE3, DE4, EN3, EN4, ES3, ES4, FR4, IT3, IT4
DE3, DE4, EN3, EN4, ES3, ES4, FR3, IT3, IT4
GD1, GD2
GK1, GK2, GK5, GU6
One of a C03, C10, C30 or C90
—
H03, H10, H30, H90
—
GM1, GM2, GM5, GM6
B Frame or Larger
A Frame
HAB, HAP, HA1, HA2
AA, AE, AN
AJ, AF
HJP, HJ2
AF, AJ
AA, AE, AN
HJPE, HJ3E
AF, AJ
AA, AE, AN
HHPE, HH3E
—
—
IT3
IT4
—
—
DE3, DE4, EN3, EN4, ES3, ES4, FR3, FR4, IT4
DE3, DE4, EN3, EN4, ES3, ES4, FR3, FR4, IT3
KA005, KA010
KB005, KB010, KB050
KC005, KC010, KC050
200-240V Drives
380-480V Drives
500-600V Drives
380-480 or 500-600V Drives
200-240 or 500-600V Drives
200-240 or 380-480V Drives
L4
L4E
L5
L5E
L6
L6E
—
—
—
—
—
—
L4E, L5, L5E, L6, L6E
L4, L5, L5E, L6, L6E
L4, L4E, L5E, L6, L6E
L4, L4E, L5, L6, L6E
L4, L4E, L5, L5E, L6E
L4, L4E, L5, L5E, L6
MX3
—
—
NCM
F Frame Drives Only
CM, A-E & G Frame Drives
SG2
SG4
—
—
—
—
SM1
—
—
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
155
Configured Drives Program
The Configured Drives Program allows users to create custom drive
packages based on their specific needs. A complete drive package
may be specified by assembling a single catalog number string that
includes a base drive and all required options. Packaging is available
in NEMA Type 1, 4 or 12 enclosures. The complexity of a chosen
option list will determine delivery time for the package.
How to Order:
•
Step 1
Select the basic Drive Catalog Number based on application
requirements (i.e. nominal HP, voltage and enclosure type). The
basic package will include a standard drive, Language Module,
115V Control Interface Board, drive branch fusing and enclosure.
•
Step 2
Specify Options — The following pages list and describe the
available options. The listing is divided into simple categories to
assist in quickly locating specific needs. Some options are
horsepower and/or voltage specific, or will have special rules
associated with them — Read all Footnotes.
All options will be further defined by a lead-time code. The lead-
time of a specific Configured Drive package will be equal to the
published lead-time of the worst case option.
Example:
A user requires a variable speed control for an existing 3 HP,
230VAC conveyor motor. Both drive and motor will be located in a
clean environment. Local control is required for programming, start,
stop, speed and emergency stop. Operation across the line (with selec-
tion and mode indication at drive) is required. A drive mode discon-
nect switch should be available. The speed reference will be supplied
either local or from an isolated remote process control and should be
selectable at the drive. 250VA control power is required. The motor
has a cooling blower that requires control.
➊
Lead-time-worst case is “Q,” thus lead-time is the published value for “Configured Drives with Q
options only”.
CONFIGURED DRIVES PROGRAM
Description
Catalog No./Option Code
❋
Lead-Time
Code
Basic Drive
1336S-AF30C
P
IP 20 (NEMA Type 1) Enclosure
-AA
P
Human Interface Module
-HA1C (or HA2C)
P
“Drive Disable” Pushbutton
-D51 (or D52)
P
Bypass, Manual with D/O/B Switch
-BM
P
Drive & Bypass Mode Pilot Lights
-D41
P
Drive Disconnect Switch
-DS
P
Auto/Manual Selector Switch (speed)
-D15
P
Control Power, Extra 250VA
-CP
P
Blower Motor Starter
-MB
Q
➊
1336S-AF30C-AA-BM-CP-DS-D15-D41-D51-HA1-MB
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
156
Allen-Bradley
Catalog Number Structure
CONFIGURED DRIVES PROGRAM
1336S –
B 020 C – AA
–
BM – GM1C – HA1C – . . .
Bulletin Number
kW (HP) Rating
Code
CT
VT
➊
F05
0.37 (0.5)
0.37 (0.5)
F07
0.56 (0.75)
0.56 (0.75)
F10
0.75 (1)
0.75 (1)
F15
1.2 (1.5)
1.2 (1.5)
F20
1.5 (2)
1.5 (2)
F30
2.2 (3)
2.2 (3)
F50
3.7 (5)
3.7 (5)
F75
5.5 (7.5)
7.5 (10)
F100
7.5 (10)
11 (15)
X007
–
5.5 (7.5)
007
5.5 (7.5)
7.5 (10)
010
7.5 (10)
11 (15)
015
11 (15)
15 (20)
020
15 (20)
18.5 (25)
025
18.5 (25)
–
030
22 (30)
22 (30)
X040
30 (40)
30 (40)
040
–
37 (50)
050
37 (50)
–
X060
45 (60)
45 (60)
060
–
56 (75)
075
56 (75)
75 (100)
100
75 (100)
93 (125)
125
93 (125)
112 (150)
150
112 (150)
149 (200)
200
149 (200)
187 (250)
250
187 (250)
187 (250)
X250
–
224 (300)
300
224 (300)
261 (350)
350
261 (350)
298 (400)
400
298 (400)
336 (450)
450
336 (450)
373 (500)
500
373 (500)
448 (600)
600
448 (600)
–
Voltage
Code
Volts
A
230VAC
B
460VAC
C
575VAC
Enclosure
Code
Description
AA
IP 20 (NEMA Type 1)
AF
IP 65 (NEMA Type 4)
AJ
IP 54 (NEMA Type 12)
Duty
Code
Description
C
Constant Torque
V
Variable Torque
➊
Applies to 460V AC Drives Only.
Options As Required
Code
Description
Page
-A208
208V AC Input
-BA
Bypass, Auto
-BC
Bypass, Auto, SMC-Pump
-BD
Bypass, Auto, SMC
-BM
Bypass, Manual
-BP
Bypass, Man., SMC-Pump
-BS
Bypass, Manual, SMC
-CB
Circuit Breaker, Drive
-CC
Circuit Breaker, Bypass
-CF
Control Power-Drive
-CM
Common Mode Choke
-CP
Control Power, Plus 250VA
-CT
Control Power, Plus 500VA
-DE3C
Language Module-German V3.04 168
-DE4C
Language Module-German V4.xx 168
-DS
Disconnect Sw., Drive
-DT
Disconnect Sw., Bypass
-D10
Start, Stop, Jog, A/M
-D11
H/O/A and A/M Switches
-D12
D11 Plus Pilot Lights
-D13
H/O/A Selector Sw.
-D14
D13 Plus PIlot Lights
-D15
A/M Selector Sw.
-D16
D15 Plus Pilot Lights
-D17
Start and Stop P.B.’s
-D18
Start, Stop, A/M
-D19
Start, Stop, Jog
-D21
Pilot Light Package
-D22
Pilot Light Package
-D31
At Speed Pilot Light
-D32
Forward/Reverse S.S.
-D41
Drive & Bypass Lights
-D42
Auto Bypass Enable
Off/On S.S. and Bypass P.L.
-D51
Drive Disable P.B. (Contactor)
-D52
Drive Disable P.B. (Enable)
-D61
Speed Pot.
-D91
800T Conversion
-EB
Voltage Barrier
-EC
Enclosure Fan and Filter(s)
-EF1
Enclosure Floor Stand 305 mm (12")174
-EF2
Enclosure Floor Stand 610 mm (24")174
-EG
Enclosure Fan, Filters & Gasketed 174
-EH
Enclosure Heater, Remote Power 174
-EH2
Enclosure Heater, Local Power
-EN3C
Language Module-English V3.04
-EN4C
Language Module-English V4.xx
-EP1
Enclosure Paint-Special, 1 Color
-EP2
Enclosure Paint-Special, 2 Color
-EP3
Enclosure Paint-Special, 3 Color
-ES3C
Language Module-Spanish V3.04 168
-ES4C
Language Module-Spanish V4.xx 168
-ET
Enclosure Nameplate
-FM
Fuse Block, Motor
-FR3C
Language Module-French V3.04
-FR4C
Language Module-French V4.xx
-GD1C
Single Point RI0
-GD2C
RS232/422/485, DF1
-GM1C
Single Point RI0
-GM2C
RS232/422/485, DF1
-GM5C
DeviceNet
-GM6C
Enhanced DeviceNet
Code
Description
Page
-HABC
HIM, Blank, NEMA Type 1
-HAPC
HIM, Programmer, NEMA Type 1 170
-HA1C
HIM, Analog, NEMA Type 1
-HA2C
HIM, Digital, NEMA Type 1
-HJPC
HIM, Prog., IP65 (NEMA Type 12) 170
-HJ2C
HIM, Digital, IP65 (NEMA Type 12)170
-HJPEC
G.P.T., Programmer
-HJ3EC
G.P.T. w/Run Time
-HNBC
HIM Blank, Open
-HNPC
HIM, Programmer, Open
-HN1C
HIM, Analog, Open
-HN2C
HIM, Digital, Open
-IT3C
Language Module-Italian V3.04
-IT4C
Language Module-Italian V4.xx
-JA
Analog Outputs, 4-20MA
-JC
Contacts, Control Power On
-JF
Contacts, Fault
-JL
PLC® Hardware & Mounting
-JM
Contacts, Alarm
-JR
Contacts, Run
-JS
SLC Hardware & Mounting
-JT
Contacts, At Speed
-KD
Contactor, Drive Input
-KM
Contactor, Drive Output
-L4C
Control Interface, TTL
-L4EC
Control Int., TTL, Encoder
-L5C
Control Interface, 24V
-L5EC
Control Int., 24V, Encoder
-L6C
Control Interface, 115VAC (Std.) 169
-L6EC
Control Int., 115V, Encoder
-LQ
Line Reactor, Mtd. & Wired,
NEMA Type 1 Output
-LR
Line Reactor, NEMA Type 1
Mtd. & Wired, Input
-LT
Line Reactor, Mtd., NEMA Type 4 163
or Type 12 Input
-LW
Line Reactor, Mtd., NEMA Type 4 163
or 12 Output
-MB
Blower Motor Starter
-MC
Custom Meter
-ME
Elapsed Time Meter
-MH
Motor Heater Cntrl, Remote Power170
-MH2
Motor Heater Cntrl, Local Power
-MK
Thermal Overload-Class 20
-MQ
Line Metering System
-MQ2
Line Metering System, Delux
-MT
Thermal Overload-Class 10
-MX3
Conformal Coating
-N2
Analog Output Isolator
-N3
Analog Input Isolator
-N4C
Transducer, Local, Command
-N4T
Transducer, Local, Trim
-N5C
Transducer, Remote, Command
-N5T
Transducer, Remote, Trim
-N6A
RTD Protection, 120 Ohm NIckel 170
-N7A
RTD Protection 10 Ohm Copper
-N8A
RTD Protection, 100 Ohm Platinum170
-N9
Thermistor Sensing Relay
-UL
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
157
230VAC Input Constant Torque Drive & Enclosure
Package Includes:
•
Standard Drive
•
English/English Language Module (-EN4)
•
115VAC Control Interface Board (-L6)
•
Drive Branch Fusing
•
Enclosure (refer to dimensions on pages 177 – 178)
➊
As many valid options as required may be strung together with a dash between each option code
number.
➋
Drive Rating is based on nominal voltage of 240 volts and a carrier frequency of 4 kHz at altitudes
of 1000 meters or less. Refer to Publication 1336 PLUS-1.0 for derating information.
➌
If a door mounted HIM is supplied, the enclosure rating is limited to IP 65 (NEMA and UL do not
apply).
➍
All D frame and larger IP 54 (NEMA Type 12) drives will include a closed loop air conditioner
system when required.
CONFIGURED DRIVES PROGRAM
1336S
–
AF15C-AA
–
HA1C
–
GD1C
–
BM
Bulletin Number
Rating-Enclosure
(must be specified)
Human Interface
(optional)
➊
Communication
Option
(optional)
➊
Remaining Options
(as/if required)
➊
Frame
Constant Torque Drive
Rating
➋
IP 20 (NEMA Type 1)
General Purpose
IP 65 (NEMA Type 4)
➌
Resist Water, Dust
IP 54 (NEMA Type 12)
➍
Industrial Use, Dust
kW (HP)
Output A
Code
❋
Code
❋
Code
❋
Important:
The basic drive does
not include a control power trans-
former. If local 115VAC power is
not available, see options CF, CP
& CT on page 166.
Optional 208V AC Rating: Add
option -208.
A1
0.37 (0.5)
0.56 (0.75)
0.75 (1)
2.3
3.0
4.5
AF05C-AA
AF07C-AA
AF10C-AA
AF05C-AF
AF07C-AF
AF10C-AF
AF05C-AJ
AF07C-AJ
AF10C-AJ
A2
1.2 (1.5)
1.5 (2)
6.0
8.0
AF15C-AA
AF20C-AA
AF15C-AF
AF20C-AF
AF15C-AJ
AF20C-AJ
A3
2.2 (3)
3.7 (5)
12.0
18.0
AF30C-AA
AF50C-AA
AF30C-AF
AF50C-AF
AF30C-AJ
AF50C-AJ
B1
5.5 (7.5)
27.0
A007C-AA
A007C-AF
A007C-AJ
B2
7.5 (10)
11 (15)
34.0
48.0
A010C-AA
A015C-AA
A010C-AF
A015C-AF
A010C-AJ
A015C-AJ
C
15 (20)
18.5 (25)
22 (30)
65.0
77.0
80.0
A020C-AA
A025C-AA
A030C-AA
A020C-AF
A025C-AF
A030C-AF
A020C-AJ
A025C-AJ
A030C-AJ
D
30 (40)
37 (50)
45 (60)
120.0
150.0
180.0
A040C-AA
A050C-AA
A060C-AA
Requires Custom
Quote
A040C-AJ
A050C-AJ
A060C-AJ
E
56 (75)
75 (100)
93 (125)
240.0
291.0
325.0
A075C-AA
A100C-AA
A125C-AA
A075C-AJ
A100C-AJ
A125C-AJ
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
158
Allen-Bradley
460VAC Input Constant Torque Drive & Enclosure
Package Includes:
•
Standard Drive
•
English/English Language Module (-EN4)
•
115VAC Control Interface Board (-L6)
•
Drive Branch Fusing
•
Enclosure (refer to dimensions on pages 177 – 178)
➊
As many valid options as required may be strung together with a dash between each option code number.
➋
Drive Rating is based on nominal voltage of 480 and a carrier frequency of 4 kHz (187 kW/250 HP and below) or 2 kHz
(224 kW/300 HP and above) at altitudes of 1000 meters or less. Refer to 1336 PLUS-1.0 for derating information.
➌
If a door mounted HIM is supplied, the enclosure rating is limited to IP 65 (NEMA and UL do not apply).
➍
All D frame and larger IP 54 (NEMA Type 12) drives will include a closed loop air conditioner system when required.
➎
This Drive Rating is based upon a maximum of 4 kHz carrier frequency.
CONFIGURED DRIVES PROGRAM
1336S
–
B075C-AA
–
HA1C
–
GM1C
–
BM
Bulletin Number
Rating-Enclosure
(must be specified)
Human Interface
(optional)
➊
Communication Option
(optional)
➊
Remaining Options
(as/if required)
➊
Frame
Constant Torque
Drive Rating
IP 20 (NEMA Type 1)
General Purpose
IP 65 (NEMA Type 4)
➌
Resist Water, Dust
IP 54 (NEMA Type 12)
➍
Industrial Use, Dust
kW (HP)
Output A
Code
❋
Code
❋
Code
❋
Important:
The basic drive
does not include a control
power transformer. If local
115VAC power is not avail-
able, see options CF, CP &
CT on page 166.
A1
0.37 (0.5)
0.56 (0.75)
0.75 (1)
1.2 (1.5)
1.1
1.6
2.1
2.8
BF05C-AA
BF07C-AA
BF10C-AA
BF15C-AA
BF05C-AF
BF07C-AF
BF10C-AF
BF15C-AF
BF05C-AJ
BF07C-AJ
BF10C-AJ
BF15C-AJ
A2
1.5 (2)
2.2 (3)
3.8
5.3
BF20C-AA
BF30C-AA
BF20C-AF
BF30C-AF
BF20C-AJ
BF30C-AJ
A3
3.7 (5)
8.4
BF50C-AA
BF50C-AF
BF50C-AJ
A4
5.5 (7.5)
7.5 (10)
14.0
17.5
BF75C-AA
BF100C-AA
BF75C-AF
BF100C-AF
BF75C-AJ
BF100C-AJ
B1
5.5 (7.5)
7.5 (10)
11 (15)
12.5
16.1
24.2
B007C-AA
B010C-AA
B015C-AA
B007C-AF
B010C-AF
B015C-AF
B007C-AJ
B010C-AJ
B015C-AJ
B2
15 (20)
18.5 (25)
22 (30)
31.0
39.0
45.0
B020C-AA
B025C-AA
B030C-AA
B020C-AF
B025C-AF
B030C-AF
B020C-AJ
B025C-AJ
B030C-AJ
C
30 (40)
37 (50)
45 (60)
➎
59.0
75.0
77.0
➎
BX040C-AA
B050C-AA
BX060C-AA
BX040C-AF
B050C-AF
BX060C-AF
BX040C-AJ
B050C-AJ
BX060C-AJ
D
45 (60)
56 (75)
75 (100)
93 (125)
112 (150)
85.0
106.0
138.0
173.0
180.0
B060C-AA
B075C-AA
B100C-AA
B125C-AA
BX150C-AA
Requires Custom
Quote
B060C-AJ
B075C-AJ
B100C-AJ
B125C-AJ
BX150C-AJ
E
112 (150)
149 (200)
187 (250)
199.0
263.0
325.0
B150C-AA
B200C-AA
B250C-AA
B150C-AJ
B200C-AJ
B250C-AJ
F
187 (250)
224 (300)
261 (350)
298 (400)
325.0
360.0
425.0
475.0
BP250C-AA
BP300C-AA
BP350C-AA
BP400C-AA
BP250C-AJ
BP300C-AJ
BP350C-AJ
BP400C-AJ
336 (450)
532.0
BP450C-AA
Requires Custom Quote
G
224 (300)
261 (350)
298 (400)
360.0
425.0
475.0
B300C-AA
B350C-AA
B400C-AA
B300C-AJ
B350C-AJ
B400C-AJ
336 (450)
373 (500)
448 (600)
525.0
590.0
670.0
B450C-AA
B500C-AA
B600C-AA
Requires Custom
Quote
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
159
❋
Prices – Consult Sales Office or price list
460VAC Input Variable Torque Drive & Enclosure
Package Includes:
•
Standard Drive
•
English/English Language Module (-EN4)
•
115VAC Control Interface Board (-L6)
•
Drive Branch Fusing
•
Enclosure (refer to dimensions on pages 177 – 178)
➊
As many valid options as required may be strung together with a dash between each option code.
➋
Drive rating is based on nominal voltage of 480 volts and a carrier frequency of 4 kHz (45 kW/60 HP and below) or 2
kHz (56 kW/75 HP and above) at altitudes of 1000 meters or less. Refer to Publication 1336 PLUS-1.0 for derating
information.
➌
If a Door Mounted HIM is supplied, the Enclosure Rating is limited to IP 65 (NEMA and UL do not apply).
➍
All D frame and larger IP 54 (NEMA Type 12) drives will include a closed loop air conditioner system when required.
CONFIGURED DRIVES PROGRAM
1336S
–
B075V-AA
–
HA1C
–
GM1C
–
BM
Bulletin Number
Rating-Enclosure
(must be specified)
Human Interface
(optional)
➊
Communication Option
(optional)
➊
Remaining Options
(as/if required)
➊
Frame
Variable Torque
Drive Rating
➋
IP 20 (NEMA Type 1)
General Purpose
IP 65 (NEMA Type 4)
➌
Resist Water, Dust
IP 54 (NEMA Type 12)
➍
Industrial Use, Dust
kW (HP)
Output A
Code
❋
Code
❋
Code
Important:
The basic drive
does not include a control
power transformer. If local
115VAC power is not avail-
able, see options CF, CP &
CT on page 166.
Important:
When choosing
kW/HP related options for
variable torque drives, match
the option to the actual vari-
able torque kW/HP rating —
not the base catalog num-
ber. For example: A 11kW
(15HP) variable torque drive
requires an 11kW (15HP)
circuit breaker, not a 7.5kW/
(10HP).
A1
0.37 (0.5)
0.56 (0.75)
0.75 (1)
1.2 (1.5)
1.2
1.7
2.3
3.0
BF05V-AA
BF07V-AA
BF10V-AA
BF15V-AA
BF05V-AF
BF07V-AF
BF10V-AF
BF15V-AF
BF05V-AJ
BF07V-AJ
BF10V-AJ
BF15V-AJ
A2
1.5 (2)
2.2 (3)
4.0
6.0
BF20V-AA
BF30V-AA
BF20V-AF
BF30V-AF
BF20V-AJ
BF30V-AJ
A3
3.7 (5)
9.0
BF50V-AA
BF50V-AF
BF50V-AJ
A4
7.5 (10)
11 (15)
17.5
25.0
BF75V-AA
BF100V-AA
BF75V-AF
BF100V-AF
BF75V-AJ
BF100V-AJ
B1
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
14.0
14.0
21.0
27.0
BX007V-AA
B007V-AA
B010V-AA
B015V-AA
BX007V-AF
B007V-AF
B010V-AF
B015V-AF
BX007V-AJ
B007V-AJ
B010V-AJ
B015V-AJ
B2
18.5 (25)
22 (30)
34.0
48.0
B020V-AA
B030V-AA
B020V-AF
B030V-AF
B020V-AJ
B030V-AJ
C
30 (40)
37 (50)
45 (60)
59.0
65.0
77.0
BX040V-AA
B040V-AA
BX060V-AA
BX040V-AF
B040V-AF
BX060V-AF
BX040V-AJ
B040V-AJ
BX060V-AJ
D
56 (75)
75 (100)
93 (125)
112 (150)
96.0
120.0
150.0
180.0
B060V-AA
B075V-AA
B100V-AA
B125V-AA
Requires Custom
Quote
B060V-AJ
B075V-AJ
B100V-AJ
B125V-AJ
E
149 (200)
187 (250)
187 (250)
240.0
292.0
325.0
B150V-AA
B200V-AA
B250V-AA
B150V-AJ
B200V-AJ
B250V-AJ
F
224 (300)
261 (350)
298 (400)
336 (450)
360.0
425.0
475.0
532.0
BP250V-AA
BP300V-AA
BP350V-AA
BP400V-AA
BP250V-AJ
BP300V-AJ
BP350V-AJ
BP400V-AJ
G
224 (300)
261 (350)
298 (400)
336 (450)
360.0
425.0
475.0
525.0
BX250V-AA
B300V-AA
B350V-AA
B400V-AA
BX250V-AJ
B300V-AJ
B350V-AJ
B400V-AJ
373 (500)
448 (600)
590.0
670.0
B450V-AA
B500V-AA
Requires Custom Quote
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
160
Allen-Bradley
575VAC Input Constant Torque Drive & Enclosure
Package includes:
•
Standard Drive
•
English/French Language Module (-FR4)
•
115VAC Control Interface Board (-L6)
•
Drive Branch Fusing
•
Enclosure (refer to dimensions on pages 177 – 178)
➊
As many valid options as required may be strung together with a dash between each option code.
➋
Drive Rating is based on nominal voltage of 600 volts and a carrier frequency of 4 kHz (45 kW/60 HP and below) or 2
kHz (56 kW/75 HP and above) at altitudes of 1000 meters or less. Refer to Publication 1336 PLUS-1.0 for derating
information.
➌
If a Door Mounted Human Interface Module is supplied, the Enclosure Rating is limited to IP 65 (NEMA and UL do not
apply).
➍
All D frame and larger IP 54 (NEMA Type 12) drives will include a closed loop air conditioner system when required.
CONFIGURED DRIVES PROGRAM
1336S
–
C075C-AA
–
HA1C
–
GM1
–
BM
Bulletin Number
Rating-Enclosure
(must be specified)
Human Interface
(optional)
➊
Communication Option
(optional)
➊
Remaining Options
(as/if required)
➊
Frame
Constant Torque
Drive Rating
➋
IP 20 (NEMA Type 1)
General Purpose
IP65(NEMA Type 4)
➌
Resist Water, Dust
IP 54 (NEMA Type 12)
➍
Industrial Use, Dust
kW (HP)
Output A
Code
❋
Code
❋
Code
❋
Important:
The basic drive
does not include a control
power transformer. If local
115VAC power is not avail-
able, see options CF, CP &
CT on page 166.
A4
0.75 (1)
1.5 (2)
2.2 (3)
3.7 (5)
2.0
4.0
6.0
8.0
CF10C-AA
CF20C-AA
CF30C-AA
CF50C-AA
CF10C-AF
CF20C-AF
CF30C-AF
CF50C-AF
CF10C-AJ
CF20C-AJ
CF30C-AJ
CF50C-AJ
B1
5.5 (7.5)
7.5 (10)
10.0
12.0
C007C-AA
C010C-AA
C007C-AF
C010C-AF
C007C-AJ
C010C-AJ
B2
11 (15)
15 (20)
19.0
24.0
C015C-AA
C020C-AA
C015C-AF
C020C-AF
C015C-AJ
C020C-AJ
C
18.5 (25)
22 (30)
30 (40)
37 (50)
45 (60)
30.0
35.0
45.0
57.0
62.0
C025C-AA
C030C-AA
C040C-AA
C050C-AA
C060C-AA
C025C-AF
C030C-AF
C040C-AF
C050C-AF
C060C-AF
C025C-AJ
C030C-AJ
C040C-AJ
C050C-AJ
C060C-AJ
D
56 (75)
75 (100)
93 (125)
85.0
109.0
138.0
C075C-AA
C100C-AA
C125C-AA
Requires Custom
Quote
C075C-AJ
C100C-AJ
C125C-AJ
E
112 (150)
149 (200)
187 (250)
224 (300)
158.0
252.0
284.0
300.0
C150C-AA
C200C-AA
C250C-AA
CX300C-AA
C150C-AJ
C200C-AJ
C250C-AJ
CX300C-AJ
G
224 (300)
261 (350)
298 (400)
300.0
350.0
400.0
C300C-AA
C350C-AA
C400C-AA
C300C-AJ
C350C-AJ
C400C-AJ
336 (450)
373 (500)
448 (600)
450.0
500.0
600.0
C450C-AA
C500C-AA
C600C-AA
Requires Custom Quote
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
161
Suggested Power Distribution Schemes
➊
This option is redundant to the existing electronic overload protection supplied by the drive as standard.
➋
If the motor branch fusing option (-FM) is not specified, the user must supply motor branch circuit protection.
➌
Standard drive branch fusing will be located on the optional drive disconnect switch, if supplied (except F Frame drives — because fuses are included with the
standard drive).
➍
For F Frame drive ratings — the input contactor option will be located ahead of the internal drive branch fusing.
CONFIGURED DRIVES PROGRAM
Thermal Overload Relay
Option -MK or -MT
➊
1336
PLUS
Drive
AC
Motor
Circuit Breaker
Option -CB
Output Contactor
Option -KM
Drive Branch
Fusing (Std.)
Thermal Overload Relay
Option -MK or -MT
➊
1336
PLUS
Drive
AC
Motor
Circuit Breaker
Option -CB
Drive Branch
Fusing (Std.)
Thermal Overload Relay
Option -MK or -MT
➊
1336
PLUS
Drive
AC
Motor
Output Contactor
Option -KM
Drive Branch Fusing
(Std.)
➌
Disconnect
Option -DS
➌
1336
PLUS
Drive
AC
Motor
Drive Branch Fusing
(Std.)
Circuit
Breaker
Option
-CB
Bypass/System Circuit
Breaker Option -CC
Bypass
Options
-BA or -BM
1336
PLUS
Drive
AC
Motor
Bypass/System Non-
Fused Disconnect
Option -DT
Bypass
Options
-BA or -BM
1336
PLUS
Drive
AC
Motor
Drive Branch
Fusing (Std.)
Circuit Breaker
Option -CB
Bypass/System
Circuit Breaker
Option -CC
SMC Bypass Options
-BS, BD, BP or BC
SMC
PLUS
1336
PLUS
Drive
AC
Motor
Bypass/System
Non-Fused
Disconnect
Option -DT
SMC Bypass Options
-BS, BD, BP or BC
SMC
PLUS
SMC
Fusing
Motor Branch
Fusing
Option -FM
➋
1336
PLUS
Drive
AC
Motor
Drive Branch
Fusing (Std.)
Circuit Breaker
Option -CB
SMC Bypass Options
-BS, BD, BP or BC
SMC
PLUS
SMC
Fusing
Motor Branch
Fusing
Option -FM
➋
Motor Branch
Fusing
Option -FM
➋
Motor Branch
Fusing
Option -FM
➋
Drive Branch Fusing
(Std.)
➌
SMC
Fusing
Drive Branch Fusing
(Std.)
➌
Motor Branch
Fusing
Option -FM
➋
Input Contactor
Option -KD
➍
Input Contactor
Option -KD
➍
Input Contactor
Option -KD
➍
Input Contactor
Option -KD
➍
Input Contactor
Option -KD
➍
Input Contactor
Option -KD
➍
Disconnect
Option -DS
➌
Disconnect
Option -DS
➌
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
162
Allen-Bradley
Factory Installed Options
Power Disconnecting Means
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3.
➋
Either an input contactor or output contactor may be chosen, but not both.
➌
This option must be used in conjunction with the Auxiliary Fault Contact option -JF.
➍
If a bypass option is specified, this option will no longer provide system power disconnect
capability — see options CC and DT.
CONFIGURED DRIVES PROGRAM
Option
➊
Drive
Circuit Breaker
(Option Code -CB)
➍
Drive Disconnect
Switch
(Option Code -DS)
➍
Contactor,
Drive Input
(Option Code -KD)
➋
Contactor,
Drive Output
(Option Code -KM)
➋➌
Program
(Lead-Time) Code
Drive Rating
kW (HP)
❋
List Price
❋
List Price
❋
List Price
❋
230V
460/575V
230V
460/575V
230V
460/575V
230V
460/575V
P
Q/T
X
0.37 (0.5)
•
0.56 (0.75)
•
0.75 (1)
•
1.2 (1.5)
•
1.5 (2)
•
2.2 (3)
•
3.7 (5)
•
5.5 (7.5)
•
7.5 (10)
•
11 (15)
•
15 (20)
•
18.5 (25)
•
22 (30)
•
30 (40)
•
37 (50)
•
45 (60)
•
56 (75)
•
75 (100)
•
93 (125)
•
112 (150)
•
149 (200)
•
187 (250)
•
224 (300)
•
261 (350)
•
298 (400)
•
336 (450)
•
373 (500)
•
448 (600)
•
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
163
Line Reactors and Common Mode Chokes
(Mounted and Wired Inside the Drive Enclosure)
Important:
Contact A-B for possible enclosure size changes when
supplying these options.
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3.
CONFIGURED DRIVES PROGRAM
Option
➊
3% Line Reactor mounted inside
IP 20 (NEMA Type 1) Enclosure
(Input Option Code -LR)
(Output Option Code -LQ)
3% Line Reactor mounted inside IP 65
or 54 (NEMA Type 4 or 12 Enclosure)
(Input Option Code -LT)
(Output Option Code -LW)
Common Mode Choke
mounted inside Enclosure
(Option Code -CM)
Program
(Lead-Time) Code
Drive Rating
kW (HP)
❋
❋
❋
230V
460V
575V
230V
460V
575V
230V
460V
575V
P
Q/T
X
0.37 (0.5)
•
0.56 (0.75)
•
0.75 (1)
•
1.2 (1.5)
•
1.5 (2)
•
2.2 (3)
•
3.7 (5)
•
5.5 (7.5)
•
7.5 (10)
•
11 (15)
•
15 (20)
•
18.5 (25)
•
22 (30)
•
30 (40)
•
37 (50)
•
45 (60)
•
56 (75)
•
75 (100)
•
93 (125)
•
112 (150)
•
149 (200)
•
187 (250)
•
224 (300)
•
261 (350)
•
298 (400)
•
336 (450)
•
373 (500)
•
448 (600)
•
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
164
Allen-Bradley
Bypass and Bypass Options
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3.
➋
Includes a Class 10 Adjustable Thermal Overload Relay — Refer to the 1336 PLUS-1.3 for further
information. Separate heater elements are not required.
➌
This option must be used in conjunction with the Auxiliary Fault Contact option (-JF).
➍
This option must be used in conjunction with a Bypass Option.
➎
Includes Fuse Block only. Fuses must be supplied and installed by user.
CONFIGURED DRIVES PROGRAM
Option
➊
Bypass Manual
➋➌
(Option Code -BM)
Bypass
Automatic
➋➌
(Option Code -BA)
Bypass Mode, Motor
Fuse Block
➍➎
(Option Code -FM)
Bypass/System
Mode, Circuit
Breaker
➍
(Option Code -CC)
Bypass/System Mode,
Non-Fused Disconnect
Switch
➍
(Option Code -DT)
Program
(Lead-Time) Code
Drive Rating
kW (HP)
❋
❋
❋
❋
❋
230V
460/575V
230V
460/575V
230V
460/575V
230V
460/575V
230V
460/575V
P
Q/T
X
0.37 (0.5)
•
0.56 (0.75)
•
0.75 (1)
•
1.2 (1.5)
•
1.5 (2)
•
2.2 (3)
•
3.7 (5)
•
5.5 (7.5)
•
7.5 (10)
•
11 (15)
•
15 (20)
•
18.5 (25)
•
22 (30)
•
30 (40)
•
37 (50)
•
45 (60)
•
56 (75)
•
75 (100)
•
93 (125)
•
112 (150)
•
149 (200)
•
187 (250)
•
224 (300)
•
261 (350)
•
298 (400)
•
336 (450)
•
373 (500)
•
448 (600)
•
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
165
Bypass with SMC-PLUS, and Regenerative Brakes
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3.
➋
Includes a Class 10 Adjustable Thermal Overload Relay — Refer to the 1336 PLUS-1.3 for further
information. Separate heater elements are not required.
➌
This option must be used in conjunction with the Auxiliary Fault Contact option (-JF).
➍
Consult the factory with duty cycle information to receive a custom quotation.
CONFIGURED DRIVES PROGRAM
Option
➊
Bypass, Manual
w/ SMC-PLUS
➋➌
(Option Code -BS)
Bypass, Automatic w/
SMC-PLUS
➋➌
(Option Code -BD)
Bypass, Manual w/ SMC/
Pump Option
➋➌
(Option Code -BP)
Bypass, Automatic w/
SMC/Pump Option
➋➌
(Option Code -BC)
Regenerative
Brake (1336R)
Program
(Lead-Time) Code
Drive Rating
kW (HP)
❋
❋
❋
❋
460V
230V
460/575V
230V
460/575V
230V
460/575V
230V
460/575V
P
Q/T
X
0.37 (0.5)
➍
•
0.56 (0.75)
➍
•
0.75 (1)
➍
•
1.2 (1.5)
➍
•
1.5 (2)
➍
•
2.2 (3)
➍
•
3.7 (5)
➍
•
5.5 (7.5)
➍
•
7.5 (10)
➍
•
11 (15)
➍
•
15 (20)
➍
•
18.5 (25)
➍
•
22 (30)
➍
•
30 (40)
➍
•
37 (50)
➍
•
45 (60)
➍
•
56 (75)
➍
•
75 (100)
➍
•
93 (125)
➍
•
112 (150)
➍
•
149 (200)
➍
•
187 (250)
➍
•
224 (300)
➍
•
261 (350)
➍
•
298 (400)
➍
•
336 (450)
➍
•
373 (500)
➍
•
448 (600)
➍
•
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
166
Allen-Bradley
Control Power and Thermal Overload Relay Options
Coating of Drive Printed Circuit Boards
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3.
➋
Refer to the technical overload information on the next page to confirm that the adjustable overload
range will be correct for your motor current rating.
➌
No heater elements are supplied.
CONFIGURED DRIVES PROGRAM
Option
➊
115V Control Power,
Drive/Options Only
(Option Code -CF)
115V Control Power,
Drive/Options & 250VA
(Option Code -CP)
115V Control Power,
Drive/Options & 500VA
(Option Code -CT)
Class 10 Thermal
Overload Relay
➋
(Option Code -MT)
Class 20 Thermal
Overload Relay
➌
(Option Code -MK)
Program
(Lead-Time) Code
Drive Rating
kW (HP)
❋
❋
❋
❋
❋
230V
460/575V
230V
460/575V
230V
460/575V
230V
460/575V
230V
460/575V
P
Q/T
X
0.37 (0.5)
•
0.56 (0.75)
•
0.75 (1)
•
1.2 (1.5)
•
1.5 (2)
•
2.2 (3)
•
3.7 (5)
•
5.5 (7.5)
•
7.5 (10)
•
11 (15)
•
15 (20)
•
18.5 (25)
•
22 (30)
•
30 (40)
•
37 (50)
•
45 (60)
•
56 (75)
•
75 (100)
•
93 (125)
•
112 (150)
•
149 (200)
•
187 (250)
•
224 (300)
•
261 (350)
•
298 (400)
•
336 (450)
•
373 (500)
•
448 (600)
•
Description
Option
Code
❋
Program (Lead-Time) Code
P
Q/T
X
Conformal Coating of drive printed circuit
boards for protection against dirt, moisture,
fungus and corrosion.
A-B Frames
C Frame
D Frame
E-G Frames
-MX3
•
•
•
•
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
167
Technical Information for Thermal Overload Relays
Class 10 (Bulletin 193) Relays:
•
Will trip in 10 seconds or less at 600% of device current rating.
•
Trip setting is adjustable per the range chart shown.
•
Range is chosen to cover maximum drive current rating.
•
If a motor outside the published adjustability range is to be
used — complete motor data must be supplied at order entry.
CONFIGURED DRIVES PROGRAM
Drive Rating
kW (HP)
Class 10 Adjustable Thermal Overload Relay (Option Code -MT)
Adjustable Range
230V
460V CT
460V VT
575V
0.37 (0.5)
2-3 A
1-1.6 A
1-1.6 A
—
0.56 (0.75)
2.8-4.2 A
1.5-2.3 A
1.5-2.3 A
—
0.75 (1)
4-6 A
2-3A
2-3 A
1.5-2.3 A
1.2 (1.5)
5.5-8 A
2-3 A
2.8-4.2 A
—
1.5 (2)
6-10 A
2.8-4.2 A
2.8-4.2 A
2.8-4.2 A
2.2 (3)
10-16 A
4-6 A
5.5-8 A
5.5-8 A
3.7 (5)
16-24 A
6-10 A
10-16 A
6-10 A
5.5 (7.5)
22-32 A
10-16 A
10-16 A
6-10 A
7.5 (10) A Frame
—
10-16 A
16-24 A
—
7.5 (10) B Frame
30-45 A
16-24 A
10-16 A
10-16 A
11 (15) A Frame
—
—
22-32 A
—
11 (15) B Frame
45-60 A
22-32 A
16-24 A
16-24 A
15 (20)
60-75 A
30-45 A
22-32 A
16-24 A
18.5 (25)
66-110 A
30-45 A
30-45 A
22-32 A
22 (30)
66-110 A
30-45 A
45-60 A
30-45 A
30 (40)
120-200 A
45-60 A
45-60 A
30-45 A
37 (50)
120-200 A
60-75 A
60-75 A
45-60 A
45 (60)
120-200 A
66-110 A
66-110 A
60-75 A
56 (75)
180-300 A
66-110 A
66-110 A
66-110 A
75 (100)
180-300 A
120-200 A
80-120 A
66-110 A
93 (125)
240-400 A
120-200 A
120-200 A
120-200 A
112 (150)
—
120-200 A
120-200 A
120-200 A
149 (200)
—
180-300 A
180-300 A
180-300 A
187 (250) 292 A
—
240-400 A
180-300 A
180-300 A
187 (250) 325 A
—
—
120-300 A
—
224 (300)
—
240-400 A
240-400 A
180-300 A
261 (350)
—
378-630 A
378-630 A
240-400 A
298 (400)
—
378-630 A
378-630 A
240-400 A
336 (450)
—
378-630 A
378-630 A
378-630 A
373 (500)
—
378-630 A
378-630 A
378-630 A
448 (600)
—
645-975 A
645-975 A
378-630 A
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
168
Allen-Bradley
Language Modules
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3.
➋
Replaces the standard Language Module supplied with the basic drive.
CONFIGURED DRIVES PROGRAM
Description
➊
Option Code
➋
(Firmware 3.04)
Option Code
➋
(Firmware 4.xx)
❋
Program (Lead-Time)
Code
P
Q/T
X
English/English
English/French
English/German
English/Italian
English/Spanish
-EN3C
-FR3C
-DE3C
-IT3C
-ES3C
-EN4C
(Std. on 230&460V Drives)
-FR4C
(Std. on 575V Drives)
-DE4C
-IT4C
-ES4C
•
•
•
•
•
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
169
Communication, Control Interface and Feedback Options
CONFIGURED DRIVES PROGRAM
Description
Option
Code
❋
Program (Lead-Time) Code
P
Q/T
X
Analog Input Isolation, Drive Frequency (Speed) Command -N3
•
Analog Output Isolation (1), 4-20ma, Speed, Current, Bus
Volts or Power, Programmable
-N2
•
Analog Outputs (2), Isolated, 4-20ma, Proportional to Out-
put Frequency and Current
-JA
•
Auxiliary Contacts, (2) Form C 2-N.O., 2-N.C.
Alarm
At Speed (Reprogrammable)
Control Power On
Drive Fault
Drive Run
-JM
-JT
-JC
-JF
-JR
•
•
•
•
•
Communication Options (Frames A1-A4) Panel Mtd.
Single Point RI0
RS232/422/485, DF1 and DH485 Protocol
GD1C
GD2C
•
•
Communication Options (Frames B-G) - Drive Mtd.
Single Point RI0
RS232/422/485, DF1 and DH485 Protocol
DeviceNet
Enhanced DeviceNet
GM1C
GM2C
GM5C
GM6C
•
•
•
•
Control Interface
Contact Closures
+24VDC
115VAC (Standard)
L4C
L5C
—
•
•
•
Control Interface and Encoder Feedback
Contact Closures
+24VDC
115VAC
L4EC
L5EC
L6EC
•
•
•
PLC Hardware & Mounting - includes a maximum of:
-4 Position Rack (1771-A1B)
-16 Amp Power Supply (1771-P1)
(No Programming Included)
-JL
•
SLC-500 Hardware & Mounting - includes a max. of:
-4 Position Rack (1746-A4)
-Power Supply (1746-P1)
(No Programming Included)
-JS
•
Transducer Feedback, 3-15psi, hardware mounted inside
enclosure, 4-wire, air pressure only
Command
Trim
-N4C
-N4T
•
•
Transducer Feedback, 3-15psi, transducer supplied loose
for remote mounting, 2-wire, air or fluid pressure
Command
Trim
-N5C
-N5T
•
•
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
170
Allen-Bradley
Human Interface Modules
Graphic Programming Terminals
Motor Interface Options
See page 171 for footnote information.
CONFIGURED DRIVES PROGRAM
Description
Option
Code
❋
Program (Lead-Time) Code
P
Q/T
X
Open, Mounted Inside Enclosure
Blank — No Functionality
Programmer Only
Programmer/Control w/Analog Pot
Programmer/Control w/Digital Pot
-HNBC
-HNPC
-HN1C
-HN2C
•
•
•
•
NEMA Type 1 Door Mounted in Bezel
Blank — No Functionality
Programmer Only
Programmer/Control w/Analog Pot
Programmer/Control w/Digital Pot
-HABC
-HAPC
-HA1C
-HA2C
•
•
•
•
NEMA Type 12/IP 65 Door Mounted
Programmer Only
Programmer/Control w/Digital Pot
-HJPC
-HJ2C
•
•
Description
Option
Code
❋
Program (Lead-Time) Code
P
Q/T
X
NEMA Type 1/12
Programmer Only
Programmer/Run Time Functions
-HJPEC
-HJ3EC
•
•
Description
Option
Code
List
Price
❋
Program (Lead-Time) Code
P
Q/T
X
Blower Motor Starter
-MB
•
Motor Heater Control, 120VAC, 360W,
Remote Power
Local Power
-MH
-MH2
•
•
RTD Protection Module, Monitors Up to (3)
Motor Mounted RTD’s
120 Ohm Nickel
10 Ohm Copper
100 Ohm Platinum
-N6A
-N7A
-N8A
•
•
•
Thermistor Sensing Relay
-N9
•
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
171
Codes and Standards
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3.
➋
Replaces the standard Language Module supplied with the basic drive.
➌
The contact outputs provided with this option may be reprogrammed to At Frequency, At Current
or At Torque.
➍
A maximum of one drive mounted communication option is permitted. If additional communication
options are required, specify the Panel Mount style.
➎
Can not be used with operator device options D12, D14 and D16.
➏
Specific requirements must be supplied at time of order entry. Both PLC and SLC hardware
mounting is not available on the same drive.
➐
This option may be used on an IP 65 Rated Enclosure to meet Watertight Indoor Applications.
➑
Includes a Class 10 Adjustable Thermal Overload Relay. Adjustability range will be based on
standard motor data. Separate heater elements are not required. This option will handle a
maximum blower motor rating of 0.75 kW (1 HP), 460V, 1.7A.
❾
This option must be used in conjunction with the Auxiliary Run Contact option (-JR).
Operator Device Function Guide
See page 173 for actual Operator Device Options
.
➊
The function of the “Auto Mode” speed reference is dependent upon the programming of [Freq
Select 2], parameter 6 in the drive. The use of an Isolated Signal Conditioner (option -N3) is
recommended for any analog signal being fed to the drive.
CONFIGURED DRIVES PROGRAM
Program (Lead-Time) Code
Code/Standard
Action
P
Q/T
X
CE
(European Conformance Standard)
Custom Quote Required — Consult the
factory with your requirements to meet
the separate Low Voltage and/or EMC
directives.
•
IEEE519
(Harmonic Distortion Levels)
Custom Quote Required — Provide a
one-line power distribution drawing, and
the associated customer specification to
the factory, for review.
•
UL, C-UL (CSA)
P and Q type options will automatically be
UL and C-UL. If the desired catalog string
contains any “X” type options, and UL or
C-UL is required, add a “-UL” option to
the catalog string at no charge. This
option provides UL panel recognition from
the factory. Do Not arbitrarily add this
string, as it will increase product delivery
time.
•
Q
E
T
N
O
C
D
N
I
6
L
6
5
D
E
T
S
IL
Q
E
T
N
O
C
D
N
I
6
L
6
5
D
E
T
S
IL
Option
Device
Mode
Drive Start & Stop Control
Drive Speed Reference
Selector
Switch
or P.B.
Remote
Contact
None
Door Mounted or
Remote Speed Pot.
Parameter #5=1
Defined by Drive
Parameter #6
➊
None
D10
Start/
Stop/
Jog
•
•
•
Auto/
Manual
•
•
•
•
D11
&
D12
Hand/
Off/
Auto
•
•
•
•
•
•
Auto/
Manual
•
•
•
•
D13
&
D14
Hand/
Off/
Auto
•
•
•
•
•
•
D15
&
D16
Start/
Stop/
•
•
•
•
Auto/
Manual
•
•
•
•
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
172
Allen-Bradley
Operator Devices — Door Mounted
The operator devices listed on the next page are logically grouped
into sets. Only one option code selection may be made from each set.
Where possible 800E style devices will be supplied. Loose or individ-
ual devices are not available.
The enclosures supplied in the 1336 PLUS Configured Drives Pro-
gram will have a pre-punched enclosure door covered with a mylar
decorative plate. The operator devices as specified in the drive catalog
number will be supplied mounted and wired. The chart below indi-
cates the mounting location of specific options or option groupings.
The operator device locations are not configurable by the user.
CONFIGURED DRIVES PROGRAM
Elapsed
Time Meter
D1
D3
D6
D5
D2
Standard Enclosure Door Layout
Note: Option Set D4 is located on the Add-on Option Enclosure Door
JOG
ESC
SEL
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
173
CONFIGURED DRIVES PROGRAM
Option
Set
Description
P.B.=Pushbutton, S.S.=Selector Switch, P.L.=Pilot Light
Option
Code
❋
Program (lead-time) Code
P
Q/T
X
D1
Start P.B., Stop P.B., Jog P.B. and Auto/Manual S.S.
-D10
•
Hand/Off/Auto (Start/Stop only) S.S. and Auto/Manual
(Speed Reference only) S.S.
-D11
➊
•
D11 options plus Hand P.L. and Auto P.L.
-D12
➊➐
•
Hand/Off/Auto (Start/Stop/Speed Ref.) S.S.
-D13
➊
•
D13 option plus Hand P.L. and Auto P.L.
-D14
➊➐
•
Auto/Manual (Speed Reference only) S.S.
-D15
➊
•
D15 option plus Auto P.L. and Manual P.L.
-D16
➊➐
•
Start P.B. and Stop P.B.
-D17
•
D17 plus Auto/Manual S.S.
-D18
•
D17 plus Jog P.B.
-D19
•
D2
Control Power On, Run and Drive Fault P.L.
-D21
•
D21 options plus Motor Fault P.L.
-D22
➋
•
D3
At Speed P.L.
-D31
•
Forward/Reverse S.S.
-D32
•
D4
Drive Mode P.L. and Bypass Mode P.L.
-D41
➌
•
Bypass Mode P.L. and Auto Bypass Enabled P.L.
-D42
➍
•
D5
Drive Disable (Push-Pull) M.H.P.B.
(For use with Drive Output Contactor on Drive Enable)
-D51
➎
•
D51 but for use with Drive Enable only
-D52
➏
•
D6
Speed Potentiometer, 1-Turn, Nema Type 1/4/12
-D61
•
D9
Convert 800E Style Operator Devices
Specified to 800T Style
-D91
•
Option Set D1
Option D11
Option D13
Option D12
Option D14
Auto
A
Auto/
Manual
Auto/
Manual
Option D15
Option D17
Option D16
Hand
A
Auto/
Manual
Fwd/
Rev
Auto/
Manual
Auto/
Manual
Auto
A
Hand
A
Auto
Manual
A
A
A
Hand/Off/
Auto
Hand/Off/
Auto
Hand/Off/
Auto
Hand/Off/
Auto
Auto/
Manual
Start
PB
Stop
PB
Option D18
Option D10
Start
PB
Stop
PB
Option D19
Start
PB
Jog
PB
Stop
PB
Start
PB
Jog
PB
Stop
PB
Drive Disable
(By Output
Contactor &
Drive Enable)
MH
PB
Drive Disable
(By Drive
Enable)
MH
PB
Option Set D3
Option
D32
Option
D31
At
Speed
Option Set D2
Option D22
Option D21
Option Set D4
Standard with any
Manual Bypass
Option
Option D41
Standard with any
Auto Bypass
Option
Option D42
Bypass
Mode
A
Auto
Bypass
Off/On
Drive
Mode
A
Bypass
Mode
A
A.B.
Enable
On
A
Drive/Off/
Bypass
Drive/Off/
Bypass
Option Set D5
Option Set D6
Option D51
Option D52
Option D61
W
R
W
R
Control
Pwr. On
Run
Drive
Fault
W
R
W
Control
Pwr. On
Run
Drive
Fault
Motor
Fault
Speed
(1-Turn)
➊
Refer to page 171 for Operator Device
Function Guide.
➋
Must be used in conjunction with a Thermal
Overload or Bypass Option.
➌
Must be used in conjunction with a Bypass
Option.
➍
Must be used in conjunction with an Auto
Bypass Option.
➎
Must be used in conjunction with an Output
Contactor or Bypass Option.
➏
Can not be used with a drive having a Bypass
Option.
➐
Can not be used with 5V TTL Logic Interface
Options -L4C and -L4EC.
➋
➍
➏
➌
➎
➊
➊
➊
➊➐
➊➐
➊➐
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
174
Allen-Bradley
Meters — Door Mounted
Enclosure Options
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3
➋
This option must be used in conjunction with the Auxiliary Run Contact option (-JR).
➌
The user must consider the height of Door Mounted Operator and Programming Devices when
choosing this option.
➍
Actual message to be defined by user at order entry, otherwise will be supplied blank.
CONFIGURED DRIVES PROGRAM
Description
➊
Option
Code
❋
Program (Lead-Time) Code
P
Q/T
X
Elapsed Time Meter (Motor Hours), Non-Resettable -ME
➋
•
Line Metering System; Amps & Volts, 3-Phase
-MQ
•
Line Metering System; Amps, Volts, kW, kWH, TDH -MQ2
•
Description
➊
Option
Code
❋
Program (Lead-Time) Code
P
Q/T
X
Voltage Barrier Kit
Clear Plexiglas covers for line side of disconnecting
means, door mounted devices above 50V, and any
foreign voltage sources
-EB
•
Floor Stand (for wall mounted enclosures only)
304.8 mm (12 in.) high
609.6 mm (24 in.) high
-EF1
➌
-EF2
➌
•
•
Nameplate, Door Mounted 158.8 x 50.8 mm
(6.25 x 2 in.) white Lamacoid with black letters)
-ET
➍
•
Paint, Special Color(s)
One ColorA-C Frames
D-G Frames
Two ColorA-C Frames
D-G Frames
Three ColorA-C Frames
D-G Frames
-EP1
-EP2
-EP3
•
•
•
•
•
•
Space Heater, fin strip type, 180W
Remote Power
Local Power
-EH
➋
-EH2
➋
•
•
IP 20 (NEMA Type 1) Frames D, E & G
Ventilation Fans
Filtered Door Openings
Filtered door openings, gasketed seams
and floor cover plate
Std.
-EC
-EG
•
•
•
NEMA 3R and 4X Packaging
Consult Factory
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
175
Drawing and Test Options (For Configured Drives Only)
➊
For a more functionally complete description of each option refer to Product Data Publication 1336
PLUS-1.3
➋
Pricing shown includes one set of drawings. IF more than one set is required, consult factory.
➌
Includes viewing A-B standard test only. Any special requirements must be reviewed by Allen-
Bradley for acceptance and possible price changes.
CONFIGURED DRIVES PROGRAM
Description
➊
— One Set of . . .
Catalog
Number
❋
Program (Lead-Time) Code
P
Q/T
X
Approval Drawings 279 x 432 mm (11 x 17 in.)
One Set of Schematics and Outlines —
“Manufacture Held Until Prints Approved”
Black & Whites
Vellums
1301-APPDWG
1301-APPRV
•
•
Manufacturing Drawings 279 x 432 mm (11 x 17 in.)
One set of schematics & outlines -
“Information Only — Manufacture Proceeding”
Not to be used as Approval Drawings
Black & Whites
Vellums
1301-MFDWG
1301-MFRV
•
•
Final Drawings as shipped 279x432mm(11x17 in.) One set of
schematics & outlines —
“Same Drawings Will Ship as Standard in the Instruction
Manual”
Black & Whites
Vellums
Mylar
1301-FINDWG
1301-FINRV
1301-FINRM
•
•
•
Test Report, Drive Only
1301-TESTR
•
Certified Motor Dimension Drawing
1301-CERMTR
•
Certified Transformer Dimension Drawing
1301-CERXFR
•
Certified Line Reactor Dimension Drawing
1301-CERLR
•
Disk Copy of “Final As Shipped” Schematics (Autocad)
1301-DISK
•
Witness Test, User Viewing of A-B Standard Test Procedures
1301-WT
➌
•
❋
Prices – Consult Sales Office or price list
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
176
Allen-Bradley
Option Selection Reference Chart
CONFIGURED DRIVES PROGRAM
Option Must Be Used With . . .
Cannot Be Used With . . .
A208
230V Base Drives
460 or 575V Base Drives
AA
AF
AJ
AF, AJ, HJPC, HJ2C
AA, AJ, HABC, HAPC, HA1C, HA2C
AA, AF, HABC, HAPC, HA1C, HA2C
BA
BC
BD
BM
BP
BS
JF
JF
JF
JF
JF
JF
BC, BD, BM, BP, BS, KM, MK, MT
BA, BD, BM, BP, BS, KM, MK, MT
BA, BC, BM, BP, BS, KM, MK, MT
BA, BC, BD, BP, BS, KM, MK, MT
BA, BC, BD, BM, BS, KM, MK, MT
BA, BC, BD, BM, BP, KM, MK, MT
CB
CC
CF
CM
CP
CT
One: BA, BC, BD, BM, BP or BS
DS
DT
CP, CT
CF, CT
CF, CP
DE3C
DE4C
DE4C, EN3C, EN4C, ES3C, ES4C, FR3C,
FR4C, IT3C, IT4C
DE3C, EN3C, EN4C, ES3C, ES4C, FR3C,
FR4C, IT3C, IT4C
DS
CB
DT
One: BA, BC, BD, BM, BP or BS
CC
D10
D11
D12
D13
D14
D15
D16
D17
D18
D19
D21
D22
D31
D32
D41
D42
D51
D52
D61
D91
One of: BA, BC, BD, BM, BP, BS,
MK or MT
One of: BA, BC, BD, BM, BP or
BS
One of: BA, BC, BD
One of: BA, BC, BD, BM, BP, BS
or KM
At least one: D10-19, D21-D22,
D31-32, D41-42, D51 or D52
D11-D19, HA1C, HA2C, HJ2C, HJ3EC
D10, D12-D19
D10, D11, D13-D19, L4C, L4EC
D10-D12, D14-D19
D10-D13, D15-D19, L4C, L4EC
D10-D14, D16-D19
D10-D15, D17-D19, L4C, L4EC
D10-D16, D18, D19, HA1C, HA2C, HJ2C,
HJ3EC
D10-D17, D19, HA1C, HA2C, HJ2C, HJ3EC
D10-D18, HA1C, HA2C, HJ2C, HJ3EC
D22
D21
D32
D31, BA, BC, BD, BM, BP, BS, CC, DT, FM,
HA1C, HA2C, HJ2C, HJ3EC
D42
D41, BM, BP, BS
D52
D51, BA, BC, BD, BM, BP, BS
HA1C, HA2C, HJ2C, HJ3EC
EB
EC
AA, Frames D-G
AF, AJ, EG, Frames A-C
EF1
EF2
Wall Mounting Enclosures
(Frames A-C)
Wall Mounting Enclosures
(Frames A-C)
B060C-B600C, B060V-B500V,
C075C-C600C, EF2 (Frames D-G)
B060C-B600C, B060V-B500V,
C075C-C600C, EF1 (Frames D-G)
EG
AA, Frames D-G
AF, AJ, EC, Frames A-C
EH
EH2
JR
JR
EH2
EH
EN3C
EN4C
DE3C, DE4C, EN4C, ES3C, ES4C, FR3C,
FR4C, IT3C, IT4C, 230 & 460V Drives
DE3C, DE4C, EN3C, ES3C, ES4C, FR3C,
FR4C, IT3C, IT4C, 230 & 460V Drives
EP1
EP2
EP3
EP2, EP3
EP1, EP3
EP1, EP2
ES3C
ES4C
DE3C, DE4C, EN3C, EN4C, ES4C, FR3C,
FR4C, IT3C, IT4C
DE3C, DE4C, EN3C, EN4C, ES3C, FR3C,
FR4C, IT3C, IT4C
ET
FM
One: BA, BC, BD, BM, BP or BS
FR3C
FR4C
DE3C, DE4C, EN3C, EN4C, ES3C, ES4C,
FR4C, IT3C, IT4C, 575V Drives
DE3C, DE4C, EN3C, EN4C, ES3C, ES4C,
FR3C, IT3C, IT4C, 575V Drives
Option Must Be Used With . . .
Cannot Be Used With . . .
GD1C
GD2C
GM1C
GM2C
GM1C
GM2C
GM5C
GM6C
GD1C, GM2C, GM5C, Frame A Drives
GD2C, GM1C, GM5C, Frame A Drives
GM1C, GM2C, Frame A Drives
GM1C, GM2C, GM5C, Frame A Drives
HABC
HAPC
HA1C
HA2C
AA
AA
AA
AA
AF, AJ, HAPC, HA1C, HA2C, HJPC, HJ2C,
HJPEC, HJ3EC
AF, AJ, HABC, HA1C, HA2C, HJPC, HJ2C,
HJPEC, HJ3EC
AF, AJ, D10, D17, D18, D19, HABC, HAPC,
HA2C, HJPC, HJ2C, HJPEC, HJ3EC
AF, AJ, D10, D17, D18, D19, HABC, HAPC,
HA1C, HJPC, HJ2C, HJPEC, HJ3EC
HJPC
HJ2C
AF or AJ
AF or AJ
AA, HABC, HAPC, HA1C, HA2C, HJ2C,
HJPEC, HJ3EC
AA, D10, D17, D18, D19, HABC, HAPC,
HA1C, HA2C, HJPC, HJPEC, HJ3EC
HJPEC
HJ3EC
AA or AJ
AA or AJ
AF, HABC, HAPC, HA1C, HA2C, HJ3EC,
HJPC, HJ2C
AF, D10, D17, D18, D19, HABC, HAPC, HA1C,
HA2C, HJPEC, HJPC, HJ2C
HJPEC
HJ3EC
AA or AJ
AA or AJ
AF, HABC, HAPC, HA1C, HA2C, HJ3EC,
HJPC, HJ2C
AF, D10, D17, D18, D19, HABC, HAPC, HA1C,
HA2C, HJPEC, HJPC, HJ2C
HNBC
HNPC
HN1C
HN2C
HNPC, HN1C, HN2C
HNBC, HN1C, HN2C
HNBC, HNPC, HN2C
HNBC, HNPC, HN1C
IT3C
IT4C
DE3C, DE4C, EN3C, EN4C, ES3C, ES4C,
FR3C, FR4C, IT4C
DE3C, DE4C, EN3C, EN4C, ES3C, ES4C,
FR3C, FR4C, IT3C
JA
N2
JC, JF
JL
JS
JM, JR
JS
JL
JT
KD
KM
KM
JF
BA, BC, BD, BM, BP, BS, KD
L4C
L4EC
L5C
L5EC
L6EC
L4EC, L5C, L5EC, L6EC, D12, D14, D16
L4C, L5C, L5EC, L6EC, D12, D14, D16
L4C, L4EC, L5EC, L6EC
L4C, L4EC, L5C, L6EC
L4C, L4EC, L5C, L5EC
LQ
AA
AF, AJ, LT, LW
LR
AA
AF, AJ, LT, LW
LT
AF or AJ
AA, LR, LQ
LW
AF or AJ
AA, LR, LQ
MB
ME
JR
MH
MH2
JR
JR
MH2
MH
MK
BA, BC, BD, BM, BP, BS, MT
MT
BA, BC, BD, BM, BP, BS, MK
MQ
MQ2
MQ2
MQ
N2
JA
N3
N4C
N5C, N5T, N4T
N4T
N5C, N5T, N4C
N5C
N4C, N4T, N5T
N5T
N4C, N4T, N5C
N6A
N7A, N8A, N9
N7A
N6A, N8A, N9
N8A
N6A, N7A, N9
N9
N6A, N7A, N8A
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
177
Worst Case Enclosure Dimensions
Dimensions subject to change. Contact Allen-Bradley for certified dimension data.
.
CONFIGURED DRIVES PROGRAM
Drive & Basic
Options
(Wall Mount)
Drive & Basic
Options
(Wall Mount)
Drive & Basic
Options
(1-Bay, Free-Standing)
Drive & Basic
Options
(2-Bay, Free-Standing)
Special
Options
(Add-On Box)
Special
Options
(Add-On Box)
Drive & Drive
Mounted Options
(3-Bay, Free-Standing)
Drive
Options
(Add-On Box)
Bypass
Options
(Add-On Box)
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
H2
H1
H1
W1
W1
W1
W2
W3
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
178
Allen-Bradley
Worst Case Enclosure Dimensions
➋
➊
Options that require the add-on enclosure include; BA, BM, CC, DT, D41, D42 & JS. Options BC, BD, BP, BS, CM, LR, LT and JL may or may not require the
add-on or a custom enclosure — consult factory for further information.
➋
The “Worst Case Enclosure Dimensions” shown are for basic estimating purposes only. Careful attention must be made to the footnotes. For exact dimension
requirements, refer to publication 1336 PLUS-1.3.
CONFIGURED DRIVES PROGRAM
Drive Rating
IP 20 (NEMA Type 1) Enclosure Dimensions — mm (inches)
IP 54 (NEMA Type 12) Dimensions — mm (inches)
Volts
Constant
Torque
Frame Figure
H1
H2
W1
W2
W3
Depth
Figure
H1
H2
W1
W2
W3
Depth
230V
0.37-0.75 kW
(0.5-1 HP)
A1
1 or 2
500
(19.69)
1000
➊
(39.37)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
686
(27.00)
1194
➊
(47.00)
665
(26.17)
N/A
N/A
548
(21.59)
1.2-1.5 kW
(1.5-2 HP)
A2
1 or 2
500
(19.69)
1000
➊
(39.37)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
686
(27.00)
1194
➊
(47.00)
665
(26.17)
N/A
N/A
548
(21.59)
2.2-3.7 kW
(3-5 HP)
A3
1 or 2
500
(19.69)
1000
➊
(39.37)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
686
(27.00)
1194
➊
(47.00)
665
(26.17)
N/A
N/A
548
(21.59)
5.5-11 kW
(7.5-15 HP)
B
1 or 2
650
(25.59)
1150
➊
(45.28)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
940
(37.00)
1550
➊
(61.00)
919
(36.17)
N/A
N/A
548
(21.59)
15-22 kW
(20-30 HP)
C
1 or 2
900
(35.43)
1550
➊
(61.02)
855
(33.66)
N/A
N/A
375
(14.78)
1 or 2
1321
(52.00)
1930
➊
(76.00)
919
(36.17)
N/A
N/A
548
(21.59)
30-45 kW
(40-60 HP)
D
3 or 4
2350
(92.50)
N/A
635
(25.00)
1143
➊
(45.00)
N/A
607
(23.90)
3 or 4
2350
(92.50)
N/A
1022
(40.25)
1530
➊
(60.25)
N/A
607
(23.9)
56-93kW
(75-125HP)
E
3 or 4
2350
(92.50)
N/A
889
(35.00)
1397
➊
(55.00)
N/A
654
(25.75)
3 or 4
2350
(92.50)
N/A
1276
(50.25)
1784
➊
(70.25)
N/A
654
(25.75)
460V
0.37-1.2 kW
(0.5-1.5 HP)
A1
1 or 2
500
(19.69)
1000
➊
(39.37)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
686
(27.00)
1194
➊
(47.00)
665
(26.17)
N/A
N/A
548
(21.59)
1.5-2.2 kW
(2-3 HP)
A2
1 or 2
500
(19.69)
1000
➊
(39.37)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
686
(27.00)
1194
➊
(47.00)
665
(26.17)
N/A
N/A
548
(21.59)
3.7 kW
(5 HP)
A3
1 or 2
500
(19.69)
1000
➊
(39.37)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
686
(27.00)
1194
➊
(47.00)
665
(26.17)
N/A
N/A
548
(21.59)
5.5-7.5 kW
(7.5-10 HP)
A4
1 or 2
650
(25.59)
1150
➊
(45.28)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
940
(37.00)
1550
➊
(61.00)
919
(36.17)
N/A
N/A
548
(21.59)
5.5-22 kW
(7.5-30 HP)
B
1 or 2
650
(25.59)
1150
➊
(45.28)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
940
(37.00)
1550
➊
(61.00)
919
(36.17)
N/A
N/A
548
(21.59)
30-45 kW
(40-60 HP)
78.2 A
C
1 or 2
900
(35.43)
1550
➊
(61.02)
855
(33.66)
N/A
N/A
375
(14.78)
1 or 2
1321
(52.00)
1930
➊
(76.00)
919
(36.17)
N/A
N/A
548
(21.59)
45-112 kW
96.9A
(60-X150 HP)
D
3 or 4
2350
(92.50)
N/A
635
(25.00)
1143
➊
(45.00)
N/A
607
(23.90)
3 or 4
2350
(92.50)
N/A
1022
(40.25)
1530
➊
(60.25)
N/A
607
(23.90)
112-187 kW
(150-250 HP)
E
3 or 4
2350
(92.50)
N/A
889
(35.00)
1397
➊
(55.00)
N/A
654
(25.75)
3 or 4
2350
(92.50)
N/A
1276
(50.25)
1784
➊
(70.25)
N/A
654
(25.75)
187-336 kW
(250-450 HP)
F
4 or 5
2350
(92.50)
N/A
N/A
1270
(50.00)
2032
➊
(80.00)
851
(33.50)
4 or 5
2350
(92.50)
N/A
N/A
2230
(87.80)
2992
➊
(117.80)
851
(33.50)
187-448 kW
(250-600 HP)
G
4 or 5
2350
(92.50)
N/A
N/A
1270
(50.00)
2032
➊
(80.00)
724
(28.50)
4 or 5
2350
(92.50)
N/A
N/A
2230
(87.80)
2992
➊
(117.80)
724
(28.50)
575V
0.75-3.7 kW
(1-5 HP)
A4
1 or 2
650
(25.59)
1150
➊
(45.28)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
940
(37.00)
1550
➊
(61.00)
919
(36.17)
N/A
N/A
548
(21.59)
5.5-15 kW
(7.5-20 HP)
B
1 or 2
650
(25.59)
1150
➊
(45.28)
655
(25.79)
N/A
N/A
375
(14.78)
1 or 2
940
(37.00)
1550
➊
(61.00)
919
(36.17)
N/A
N/A
548
(21.59)
18.5-45 kW
(25-60 HP)
C
1 or 2
900
(35.43)
1550
➊
(61.02)
855
(33.66)
N/A
N/A
375
(14.78)
1 or 2
1321
(52.00)
1930
➊
(76.00)
919
(36.17)
N/A
N/A
548
(21.59)
56-93 kW
(75-125 HP)
D
3 or 4
2350
(92.50)
N/A
635
(25.00)
1143
➊
(45.00)
N/A
607
(23.90)
3 or 4
2350
(92.50)
N/A
1022
(40.25)
1530
➊
(60.25)
N/A
607
(23.90)
112-187 kW
(150-250 HP)
E
3 or 4
2350
(92.50)
N/A
889
(35.00)
1397
➊
(55.00)
N/A
654
(25.75)
3 or 4
2350
(92.50)
N/A
1276
(50.25)
1784
➊
(70.25)
N/A
654
(25.75)
187-448 kW
(250-600 HP)
G
4 or 5
2350
(92.50)
N/A
N/A
1270
(50.00)
2032
➊
(80.00)
724
(28.50)
4 or 5
2350
(92.50)
N/A
N/A
2230
(87.80)
2992
➊
(117.80)
724
(28.50)
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
Allen-Bradley
179
PLUS Ratings – 380-480V, 400V & 480V Drives
CONFIGURED DRIVES PROGRAM
Cat. No.
Constant Torque
Variable Torque
Variable Torque
Input kVA
Input Amps
Output kVA
Output Amps
Input kVA
Input Amps
Output kVA
Output Amps
Input kVA
Input Amps
Output kVA
Output Amps
380-480V DRIVES
480V DRIVES
400V DRIVES
BRF05
BRF07
BRF10
BRF15
BRF20
BRF30
BRF50
BRF75
BRF100
B007
B010
B015
B020
B025
B030
BX040
B040
B050
BX060
B060
B075
B100
B125
BX150
B150
B200
B250
BP/BPR250
BX250
B300
BP/BPR300
B350
BP/BPR350
B400
BP/BPR400
B450
BP/BPR450
B500
B600
0.9-1.0
1.3-1.6
1.7-2.1
2.2-2.6
3.0-3.7
4.2-5.1
6.6-8.0
9.5-11.6
12.2-14.7
8-11
11-14
16-21
21-26
26-33
30-38
40-50
38-48
48-60
62
54-68
69-87
90-114
113-143
148
130-164
172-217
212-268
212-268
212-268
228-288
235-297
261-330
277-350
294-371
310-392
326-412
347-438
372-470
437-552
1.3
2.0
2.6
3.3
4.6
6.4
10.0
14.5
18.5
13
17
25
32
40
46
61
58
73
75
82
105
137
172
178
197
261
322
322
322
347
357
397
421
446
471
496
527
565
664
0.9
1.3
1.7
2.2
3.0
4.2
6.7
11.2
13.9
10
13
19
25
31
36
47
48
60
61
68
84
110
138
143
159
210
259
259
259
279
287
319
339
359
378
398
424
454
534
1.1
1.6
2.1
2.8
3.8
5.3
8.4
14.0
17.5
12.5
16.1
24.2
31
39
45
59
60
75
77
85
106
138
173
180
199
263
325
325
325
360
360
425
425
475
475
525
532
590
670
1.1
1.7
2.2
2.8
3.8
5.7
8.5
13.0
18.6
12
18
23
29
36
41
50
52
62
62
77
99
124
148
148
198
241
268
297
288
330
350
371
392
412
438
470
438
552
552
1.4
2.1
2.8
3.5
4.8
7.2
10.7
15.7
22.4
14
22
28
35
43
49
61
63
75
75
93
119
149
178
178
238
290
322
357
347
397
421
446
471
496
527
565
527
664
664
1.0
1.4
1.8
2.4
3.2
4.8
7.2
12.3
17.5
11
17
22
27
33
38
47
52
61
61
76
96
120
143
143
191
233
259
287
279
319
339
359
378
398
424
454
424
534
534
1.2
1.7
2.3
3.0
4.0
6.0
9.0
15.4
22
14
21
27
34
42
48
59
65
77
77
96
120
150
180
180
240
292
325
360
360
425
425
475
475
525
532
590
532
670
670
0.9
1.4
1.8
2.3
3.2
4.7
7.0
10.3
14.7
9
14
18
23
28
32
40
41
49
62
61
78
98
117
148
157
191
212
235
228
261
277
294
310
326
347
372
347
437
437
1.4
2.1
2.8
3.5
4.8
7.2
10.7
15.7
22.4
14
22
28
35
43
49
61
63
75
75
93
119
149
178
178
238
290
322
357
347
397
421
446
471
496
527
565
527
664
664
1.0
1.4
1.8
2.4
3.2
4.8
7.2
12.3
17.5
11
17
22
27
33
38
47
52
61
61
76
96
120
143
143
191
233
259
287
279
319
339
359
378
398
424
454
424
534
534
1.33
1.89
2.55
3.33
4.44
6.66
9.99
19.43
22.00
15.54
23.31
29.97
37.74
46.62
53.28
66.60
72.15
83.25
85.47
106.56
133.20
166.50
199.80
199.80
266.40
324.12
360.75
399.60
399.60
471.75
471.75
527.25
527.25
582.75
532.05
654.90
532.00
743.70
743.70
Bulletin 1336 PLUS
Adjustable Frequency AC Drive
180
Allen-Bradley
Notes