EV-T100 TRANSISTOR
MOTOR CONTROLLER
PARAMETER TABLES
E/J2.00-3.20XM
(E/J45-65XM) [F108, A216]
PART NO. 897825
2200 SRM 596
SAFETY PRECAUTIONS
MAINTENANCE AND REPAIR
• When lifting parts or assemblies, make sure all slings, chains, or cables are correctly
fastened, and that the load being lifted is balanced. Make sure the crane, cables, and
chains have the capacity to support the weight of the load.
• Do not lift heavy parts by hand, use a lifting mechanism.
• Wear safety glasses.
• DISCONNECT THE BATTERY CONNECTOR before doing any maintenance or repair
on electric lift trucks. Disconnect the battery ground cable on internal combustion lift
trucks.
• Always use correct blocks to prevent the unit from rolling or falling. See HOW TO PUT
THE LIFT TRUCK ON BLOCKS in the Operating Manual or the Periodic Mainte-
nance section.
• Keep the unit clean and the working area clean and orderly.
• Use the correct tools for the job.
• Keep the tools clean and in good condition.
• Always use HYSTER APPROVED parts when making repairs. Replacement parts
must meet or exceed the specifications of the original equipment manufacturer.
• Make sure all nuts, bolts, snap rings, and other fastening devices are removed before
using force to remove parts.
• Always fasten a DO NOT OPERATE tag to the controls of the unit when making repairs,
or if the unit needs repairs.
• Be sure to follow the WARNING and CAUTION notes in the instructions.
• Gasoline, Liquid Petroleum Gas (LPG), Compressed Natural Gas (CNG), and Diesel fuel
are flammable. Be sure to follow the necessary safety precautions when handling these
fuels and when working on these fuel systems.
• Batteries generate flammable gas when they are being charged. Keep fire and sparks
away from the area. Make sure the area is well ventilated.
NOTE: The following symbols and words indicate safety information in this
manual:
WARNING
Indicates a condition that can cause immediate death or injury!
CAUTION
Indicates a condition that can cause property damage!
EV-T100 Transistor Motor Controller
Table of Contents
TABLE OF CONTENTS
Register Parameters ..........................................................................................................................................
General ...........................................................................................................................................................
Function Numbers .........................................................................................................................................
Control Card Checks and Adjustments ............................................................................................................
Register Parameters Tables ..............................................................................................................................
This section is for the following models:
E/J2.00-3.20XM (E/J45-65XM) [F108, A216]
©2005 HYSTER COMPANY
i
"THE
QUALITY
KEEPERS"
HYSTER
APPROVED
PARTS
2200 SRM 596
Control Card Checks and Adjustments
Register Parameters
GENERAL
This section must be used with the following sections
of this motor controller:
• EV-T100™ Transistor Motor Controller, De-
scription, Adjustments, Troubleshooting, Re-
pairs, and Theory 2200 SRM 581.
• Troubleshooting and Adjustments With a
Computer, EV-100ZX, EV-T100, SR (SEM),
and SP Motor Controllers 2200 SRM 597.
This series of control cards have an electronic device
called
an
EEPROM
(Electrically-Erasable-Pro-
grammable-Read-Only-Memory). The EEPROM has
a number of memory elements called registers.
These registers can have electronic data stored in
them to control an operation. The range of data that
can be stored in the registers is called a parameter.
A parameter is a measurement number that works
with other measurement numbers (parameters) to
define a system. The EEPROM in the control card is
a control system for the operation of the lift truck.
The EEPROM used in this series of control cards has
128 registers.
WARNING
Each register in each control card has a range
of numbers so that the control card can be used
on different models of lift trucks. This varia-
tion is needed for lift trucks of different sizes
and operating voltages. Adjustment of the reg-
ister to the wrong number for your lift truck
model can cause the truck to operate differ-
ently than normal. This different operation of
the truck can cause an injury.
NOTE: The Register Parameters Tables show the per-
mitted ranges and the default setting for each control
function. The Factory Set Parameters are the recom-
mended settings for new units. These settings will
give satisfactory performance for most applications.
Some functions can be adjusted within the permitted
range to change the lift truck operation for a specific
application. Adjustment of a register to a number
that is different than the factory setting is allowed,
but follow the instructions carefully and stay within
the minimum and maximum limits. Adjustments
other than the factory settings will cause the lift
truck to operate differently and can cause increased
wear of parts.
FUNCTION NUMBERS
The Function Numbers are code numbers for the dif-
ferent parameters that can be set for the T100 series
control cards. The Personal Computer or the Hand-
set must be used to adjust the parameters for the
control card. There is a description of the code num-
bers for the different control cards in the Register Pa-
rameters Tables. These Register Parameters Tables
have the correct setting numbers for the parameters
on each control card.
Control Card Checks and Adjustments
A Personal Computer (PC) or a Handset is used to
permit Authorized Personnel to make the follow-
ing checks and adjustments:
• Check the system status codes for both traction and
hydraulic pump SCR systems
• Check for status codes that are not regular nor con-
stant
• Check the state of charge of the battery on mo-
tor controllers with type JH/NH and JY/NY control
cards
• Check the hourmeter readings on the traction cir-
cuit and hydraulic pump SCR controllers
• Monitor or adjust the following control functions:
– Creep Speed
– Controlled Acceleration and 1A Time
– Current Limit
– Steering pump time delay and define signal in-
put (seat switch or directional switch)
– Plugging distance (Current)
– Accelerator pedal position, plug range or disable
– 1A drop out current or disable
– Field Weakening drop-out
– Field Weakening pick-up
– Regenerative Braking current limit
– Regenerative Braking drop-out
– Speed limit points (SL1, SL2, and SL3)
– Internal resistance compensation for battery
state of charge indication
– Battery voltage (36/48V is auto ranging)
• Selection of type of card operation:
– Traction circuit with Field Weakening
1
Register Parameters Tables
2200 SRM 596
– Traction circuit with Regenerative Braking and
Field Weakening
– High or low current limit for all of the above func-
tions
Register Parameters Tables
Parameters must be between the minimum and max-
imum numbers shown. Do NOT adjust a parameter
to a number that is not shown in the correct table.
See Table 1, Table 2, Table 3, Table 4, Table 5, Ta-
ble 6, and Table 7. Make sure you use the correct
table when you make adjustments. It is a good proce-
dure to check the parameter and compare the param-
eter to the number in the table before making the ad-
justment. The factory parameter, and the value (cur-
rent, time, etc.) for that parameter, are shown in the
columns indicated as Default. The minimum and
maximum parameters and their values are shown in
the columns indicated as Permitted Range.
NOTE: Check the label at the top edge of each card
case to identify the control card on your lift truck.
There are some painted letters and numbers followed
by other numbers and letters on the lower part of the
label. The last two letters on the lower part identify
the TYPE of card installed. The table titles show
these card types for the EV-100ZX motor controllers.
NOTE: Check the label at the top edge of each card
case to identify the control card on your lift truck.
There are some painted letters and numbers followed
by other numbers and letters on the lower part of the
label. The last two letters on the lower part identify
the TYPE of card installed. The table titles show
these card types for the EV-T100 motor controllers.
Make sure to read the WARNINGS and CAUTIONS
under each parameter description and in the sec-
tion Parameters, Checks and Adjustments. These
WARNINGS and CAUTIONS must be read before
entering a parameter other than the factory value.
Table 1. EV-T100 Parameters - E/J2.00-3.20XM (36 to 48V) [Traction Card Type JH/NH With
Regenerative Braking and Field Weakening, With Battery Discharge Indicator (BDI)]
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
1
Stored Statue Code
0
1
-
0
1
/255
-
2
Creep Speed
0
5%
0/255
5% to 15%
3
Controlled Acceleration
and 1A Time
20
1.8 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
255
max. amp
0/255
max. amperes
5
Plugging Distance (Current)
134
514 amp
0/141
200 to 530 amperes
6
1A Drop-Out Current
138
900 amp
0/250
2
450 to 1260 amperes
7
Field Weakening Pick-Up
(Current)
36
110 amp
0/110
0 to 228 amperes
8
Field Weakening Drop-Out
(Current)
130
487 amp
0/140
65 to 520 amperes
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
4
without seat brake.
2
2200 SRM 596
Register Parameters Tables
Table 1. EV-T100 Parameters - E/J2.00-3.20XM (36 to 48V) [Traction Card Type JH/NH With
Regenerative Braking and Field Weakening, With Battery Discharge Indicator (BDI)] (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
9
Regenerative Braking
Current Limit
175
328 amp
0/217
75 to 390 amperes
10
Regenerative Braking Start
(% ON time)
80
30%
0/255
0% to 96% ON time
11
Speed Limit 1 (maximum
motor speed, Voltage with NC
switch open) (Not Used)
0
96% of
batt.
volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum
motor speed, Voltage with NC
switch open) (Not Used)
0
96% of
batt.
volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum
motor speed, Voltage with
NC switch open)
120
64% of
batt.
volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
20
3
-
5/25
-
15
Battery Volts
200
36/48 V
184/250
36 or 48 volt operation
16
Pedal Position Plugging
47
228 amp
0/156
100 to 530 amperes
17
Card Type Selection
42
40
42
44
Select control card with
correct functions:
Regenerative Braking
18
Steering Pump Time Delay
(Seat Switch)
0
25
1.5 sec
14 sec
0/128
21/128
4
1.5 sec to 65 sec
12 to 65 sec
4
19
Maintenance Alert (hours)
0
0 to 99
20
Maintenance Alert (hours)
99
100 to 9900
21
Maintenance Speed Limit
0
None
0
180
22
Mode Reference (Reference
register for the instrument
panel display when the
battery is connected.)
-
None
None
-
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
4
without seat brake.
3
Register Parameters Tables
2200 SRM 596
Table 1. EV-T100 Parameters - E/J2.00-3.20XM (36 to 48V) [Traction Card Type JH/NH With
Regenerative Braking and Field Weakening, With Battery Discharge Indicator (BDI)] (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
25
Monitor Register
0
-
None
(Temporary storage
register.)
26
Monitor Register
0
-
None
(Temporary storage
register.)
27
Stop Plugging Set Point
65
9.7%
20/100
13.4% to 6.8%
28
Fault Count Pointer
(Must be reset to zero to
clear Status Codes)
-
-
None
(Temporary storage
register that points
to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0-99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
4
without seat brake.
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
Function Numbers 31 through 47 can be read and cleared with a Handset. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can
only be reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62 enable the lift truck to be set to four performance levels by the operator.
(If the customer does not want this function available to the operator, a service person can set all four levels
to the same setting.) Each time the operator pushes the button on the instrument panel, the performance
level will increase by one step. At the maximum (rabbit) level, the performance levels will begin at the
lowest (turtle) level again.
MODE 1
48
Controlled Acceleration
40
3.5 sec
Fcn. No. 52
255
49
FW Pick-Up Current
0
N/A
0
N/A
50
Speed Limit 1
85
80%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
30
2.6 sec
Fcn. No. 56
Fcn. No. 48
53
FW Pick-Up Current
0
None
Fcn. No. 49
Fcn. No. 57
4
2200 SRM 596
Register Parameters Tables
Table 1. EV-T100 Parameters - E/J2.00-3.20XM (36 to 48V) [Traction Card Type JH/NH With
Regenerative Braking and Field Weakening, With Battery Discharge Indicator (BDI)] (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
54
Speed Limit 1
0
None
Fcn. No. 58
Fcn. No. 50
55
Not Used
MODE 3
56
Controlled Acceleration
20
1.8 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick-Up Current
0
Fcn. No. 53
Fcn. No. 61
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
MODE 4
60
Controlled Acceleration
10
0.94 sec
8
Fcn. No. 56
61
FW Pick-Up Current
0
Fcn. No. 57
110
62
Speed Limit 1
0
None
0
Fcn. No. 58
Description
Default
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter (thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter (tens/units)
Read Only
Secure Auxiliary Hourmeter (thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
5
Register Parameters Tables
2200 SRM 596
Table 1. EV-T100 Parameters - E/J2.00-3.20XM (36 to 48V) [Traction Card Type JH/NH With
Regenerative Braking and Field Weakening, With Battery Discharge Indicator (BDI)] (Continued)
Description
Default
Lift truck number assigned by user
Lift truck number assigned by user
Table 2. EV-T100 Parameters - E2.00-3.20XM (36 to 48V) [Traction Card Type JY/NY Without
Regenerative Braking and Field Weakening, Without Battery Discharge Indicator (BDI)]
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
1
Stored Statue Code
0
1
-
0
1
/255
-
2
Creep Speed
20
5%
0/255
5% to 15%
3
Controlled Acceleration
and 1A Time
20
1.8 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
255
max. amp
0/255
max. amperes
5
Plugging Distance (Current)
85
40 amp
0/92
200 to 416 amperes
6
1A Drop-Out Current
77
700 amp
0/250
2
450 to 1260 amperes
7
Field Weakening Pick-Up
(Current)
Not
Applicable
N/A
Not
Applicable
Not Applicable
8
Field Weakening Drop-Out
(Current)
Not
Applicable
N/A
Not
Applicable
Not Applicable
9
Regenerative Braking
Current Limit
Not
Applicable
N/A
Not
Applicable
Not Applicable
10
Regenerative Braking Start
(% ON time)
Not
Applicable
N/A
Not
Applicable
Not Applicable
11
Speed Limit 1 (maximum
motor speed, Voltage with
NC switch open) (Not Used)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum
motor speed, Voltage with
NC switch open) (Not Used)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum
motor speed, Voltage with
NC switch open)
120
64% of
batt. volts
0/180
96% to 0% of battery
voltage
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
4
without seat brake.
6
2200 SRM 596
Register Parameters Tables
Table 2. EV-T100 Parameters - E2.00-3.20XM (36 to 48V) [Traction Card Type
JY/NY Without Regenerative Braking and Field Weakening, Without Battery
Discharge Indicator (BDI)] (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
14
Internal Resistance
Compensation
20
3
-
5/25
-
15
Battery Volts
200
36/48 V
184/250
36 or 48 volt operation
16
Pedal Position Plugging
47
228 amp
0/156
100 to 530 amperes
17
Card Type Selection
-
2
-
0
2
4
Select control card with
correct functions:
Plugging only
18
Steering Pump Time Delay
(Seat Switch)
0
25
1.5 sec
14 sec
0/128
21/128
4
1.5 sec to 65 sec
12 to 65 sec
4
19
Maintenance Alert (hours)
0
0 to 99
20
Maintenance Alert (hours)
99
100 to 9900
21
Maintenance Speed Limit
0
None
0
180
22
Mode Reference (Reference
register for the instrument
panel display when the
battery is connected.)
None
None
None
-
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
-
None
(Temporary storage
register.)
26
Monitor Register
0
-
None
(Temporary storage
register.)
27
Stop Plugging Set Point
65
9.7%
20/100
13.4% to 6.8%
28
Fault Count Pointer
(Must be reset to zero to
clear Status Codes)
-
-
None
(Temporary storage
register that points to
location of last recorded
fault.)
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
4
without seat brake.
7
Register Parameters Tables
2200 SRM 596
Table 2. EV-T100 Parameters - E2.00-3.20XM (36 to 48V) [Traction Card Type
JY/NY Without Regenerative Braking and Field Weakening, Without Battery
Discharge Indicator (BDI)] (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
29
Set Hourmeter (tens/units)
0
0
0-99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
4
without seat brake.
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
Function Numbers 31 through 47 can be read and cleared with a Handset. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can
only be reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62 enable the lift truck to be set to four performance levels by the operator.
(If the customer does not want this function available to the operator, a service person can set all four levels
to the same setting.) Each time the operator pushes the button on the instrument panel, the performance
level will increase by one step. At the maximum (rabbit) level, the performance levels will begin at the
lowest (turtle) level again.
MODE 1
48
Controlled Acceleration
40
3.5 sec
Fcn. No. 52
255
49
FW Pick-Up Current
0
N/A
0
N/A
50
Speed Limit 1
85
80%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
30
2.6 sec
Fcn. No. 56
Fcn. No. 48
53
FW Pick-Up Current
0
None
Fcn. No. 49
Fcn. No. 57
54
Speed Limit 1
0
None
Fcn. No. 58
Fcn. No. 50
55
Not Used
MODE 3
56
Controlled Acceleration
20
1.8 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick-Up Current
36
110 amps
Fcn. No. 53
Fcn. No. 61
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
8
2200 SRM 596
Register Parameters Tables
Table 2. EV-T100 Parameters - E2.00-3.20XM (36 to 48V) [Traction Card Type
JY/NY Without Regenerative Braking and Field Weakening, Without Battery
Discharge Indicator (BDI)] (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
MODE 4
60
Controlled Acceleration
10
0.94 sec
8
Fcn. No. 56
61
FW Pick-Up Current
83
185 amps
Fcn. No. 57
110
62
Speed Limit 1
0
None
0
Fcn. No. 107
Description
Default
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter (thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter (tens/units)
Read Only
Secure Auxiliary Hourmeter (thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by user (tens/units)
0 to 99
Lift truck number assigned by user (thou-
sands/hundreds)
100 to 9900
9
Register Parameters Tables
2200 SRM 596
Table 3. EV-T100 Parameters - E/J2.00-3.20XM (72 to 80V) (Traction Card Type JH/NH
and JY/NY With Regenerative Braking and Field Weakening)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
1
Stored Statue Code
0
1
-
0
1
/255
-
2
Creep Speed
0
5%
0/255
5% to 15%
3
Controlled Acceleration
and 1A Time
20
2.6 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
125
max. amp
0/255
max. amperes
5
Plugging Distance (Current)
50
388 amp
0/90
200 to 411 amperes
6
1A Drop-Out Current
12
489 amp
0/250
2
450 to 1260 amperes
7
Field Weakening Pick-Up
(Current)
22
88 amp
0/36
0 to 110 amperes
8
Field Weakening Drop-Out
(Current)
55
244 amp
0/70
65 to 293 amperes
9
Regenerative Braking
Current Limit
100
220 amp
0/110
75 to 235 amperes
10
Regenerative Braking Start
(% ON time)
10
3.70%
0/255
0% to 95% of battery
voltage
11
Speed Limit 1 (maximum
motor speed, Voltage with NC
switch open) (Not Used)
0
96% of
batt.
volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum
motor speed, Voltage with NC
switch open) (Not Used)
0
96% of
batt.
volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum
motor speed, Voltage with
NC switch open)
120
64% of
batt.
volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
12
3
-
5/25
-
15
Battery Volts
75
72 V
70/80
72 volt operation
15
Battery Volts
85
80 V
81/183
80 volt operation
16
Pedal Position Plugging
47
228 amp
0/100
100 to 373 amperes
17
Card Type Selection
42
42
Select control card with
correct functions:
Regen. Braking
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
10
2200 SRM 596
Register Parameters Tables
Table 3. EV-T100 Parameters - E/J2.00-3.20XM (72 to 80V) (Traction Card Type JH/NH and
JY/NY With Regenerative Braking and Field Weakening) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
18
Steering Pump Time Delay
(Seat Switch)
25
14 sec
0/128
1.5 sec to 65 seconds
19
Maintenance Alert (hours)
99
0 to 99
20
Maintenance Alert (hours)
99
100 to 9900
21
Maintenance Speed Limit
0
None
0
180
22
Mode Reference (Reference
register for the instrument
panel display when the
battery is connected.)
-
None
None
-
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
-
None
(Temporary storage
register.)
26
Monitor Register
0
-
None
(Temporary storage
register.)
27
Stop Plugging Set Point
65
9.7%
20/100
13.4% to 6.8%
28
Fault Count Pointer
(Must be reset to zero to
clear Status Codes)
-
-
None
(Temporary storage
register that points
to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0-99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
Function Numbers 31 through 47 can be read and cleared with a Handset. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can
only be reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62 enable the lift truck to be set to four performance levels by the operator.
(If the customer does not want this function available to the operator, a service person can set all four levels
to the same setting.) Each time the operator pushes the button on the instrument panel, the performance
level will increase by one step. At the maximum (rabbit) level, the performance levels will begin at the
lowest (turtle) level again.
11
Register Parameters Tables
2200 SRM 596
Table 3. EV-T100 Parameters - E/J2.00-3.20XM (72 to 80V) (Traction Card Type JH/NH and
JY/NY With Regenerative Braking and Field Weakening) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
MODE 1
48
Controlled Acceleration
40
3.5 sec
Fcn. No. 52
255
49
FW Pick-Up Current
0
N/A
0
N/A
50
Speed Limit 1
85
80%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
30
2.6 sec
Fcn. No. 56
Fcn. No. 48
53
FW Pick-Up Current
0
None
Fcn. No. 49
Fcn. No. 57
54
Speed Limit 1
0
None
Fcn. No. 58
Fcn. No. 50
55
Not Used
MODE 3
56
Controlled Acceleration
20
1.8 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick-Up Current
29
Fcn. No. 53
Fcn. No. 61
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
MODE 4
60
Controlled Acceleration
10
0.94 sec
8
Fcn. No. 56
61
FW Pick-Up Current
36
Fcn. No. 57
110
62
Speed Limit 1
0
None
0
Fcn. No. 58
Description
Default
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter (thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter (tens/units)
Read Only
Secure Auxiliary Hourmeter (thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
12
2200 SRM 596
Register Parameters Tables
Table 3. EV-T100 Parameters - E/J2.00-3.20XM (72 to 80V) (Traction Card Type JH/NH and
JY/NY With Regenerative Braking and Field Weakening) (Continued)
Description
Default
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by user
Lift truck number assigned by user
Table 4. EV-T100 Parameters - E2.00-3.20XM (72 to 80V) (Traction Card Type JY/NY) (9-inch
Motor With Regenerative Braking and Without Field Weakening)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
1
Stored Statue Code
0
1
-
0
1
/255
-
2
Creep Speed
0
5%
0/255
5% to 15%
3
Controlled Acceleration
and 1A Time
20
1.8 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
255
Max. amp
0/130
5
Plugging Distance (Current)
80
388 amp
0/55
200 to 373 amperes
6
1A Drop-Out Current
12
489 amp
0/250
2
450 to 1260 amperes
7
Field Weakening Pick-Up
(Current)
0
N/A
Not
Applicable
Not Applicable
8
Field Weakening Drop-Out
(Current)
0
65 amp
0/70
65 to 293 amperes
9
Regenerative Braking
Current Limit
100
220 amp
0/110
75 to 235 amperes
10
Regenerative Braking Start
(% ON time)
10
3.70%
0/255
0% to 95% SCR ON time
11
Speed Limit 1 (maximum
motor speed, Voltage with NC
switch open) (Not Used)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
13
Register Parameters Tables
2200 SRM 596
Table 4. EV-T100 Parameters - E2.00-3.20XM (72 to 80V) (Traction Card Type JY/NY) (9-inch
Motor With Regenerative Braking and Without Field Weakening) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
12
Speed Limit 2 (maximum
motor speed, Voltage with NC
switch open) (Not Used)
0
96% of
batt. volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum
motor speed, Voltage with
NC switch open)
120
64% of
batt. volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
12
3
-
5/25
-
15
Battery Volts
75
72 V
70/80
72 volt operation
15
Battery Volts
85
80 V
81/183
80 volt operation
16
Pedal Position Plugging
47
228 amp
0/100
100 to 373 amperes
17
Card Type Selection
42
Plugging
Regen.
FW
40
42
44
Select control card with
correct functions:
Regenerative Braking
18
Steering Pump Time Delay
(Seat Switch)
25
14 sec
0/128
1.5 sec to 65 seconds
19
Maintenance Alert (hours)
99
0 to 99
20
Maintenance Alert (hours)
99
100 to 9900
21
Maintenance Speed Limit
0
None
None/0
None to 180
22
Mode Reference (Reference
register for the instrument
panel display when the
battery is connected.)
-
None
None
-
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
-
None
(Temporary storage
register.)
26
Monitor Register
0
-
None
(Temporary storage
register.)
27
Stop Plugging Set Point
15%
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
14
2200 SRM 596
Register Parameters Tables
Table 4. EV-T100 Parameters - E2.00-3.20XM (72 to 80V) (Traction Card Type JY/NY) (9-inch
Motor With Regenerative Braking and Without Field Weakening) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
28
Fault Count Pointer
(Must be reset to zero to
clear Status Codes)
-
-
None
(Temporary storage
register that points
to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0-99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
Function Numbers 31 through 47 can be read and cleared with a Handset. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can
only be reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62 enable the lift truck to be set to four performance levels by the operator.
(If the customer does not want this function available to the operator, a service person can set all four levels
to the same setting.) Each time the operator pushes the button on the instrument panel, the performance
level will increase by one step. At the maximum (rabbit) level, the performance levels will begin at the
lowest (turtle) level again.
MODE 1
48
Controlled Acceleration
40
3.5 sec
Fcn. No. 52
255
49
FW Pick-Up Current
0
None
0
Fcn. No. 53
50
Speed Limit 1
85
80%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
30
2.6 sec
Fcn. No. 56
Fcn. No. 48
53
FW Pick-Up Current
0
None
Fcn. No. 49
Fcn. No. 57
54
Speed Limit 1
0
None
Fcn. No. 58
Fcn. No. 50
55
Not Used
MODE 3
56
Controlled Acceleration
20
1.8 sec
Fcn. No. 60
Fcn. No. 52
57
FW Pick-Up Current
0
None
Fcn. No. 53
Fcn. No. 61
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
15
Register Parameters Tables
2200 SRM 596
Table 4. EV-T100 Parameters - E2.00-3.20XM (72 to 80V) (Traction Card Type JY/NY) (9-inch
Motor With Regenerative Braking and Without Field Weakening) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
59
Not Used
MODE 4
60
Controlled Acceleration
10
0.94 sec
8
Fcn. No. 56
61
FW Pick-Up Current
0
None
Fcn. No. 57
None
62
Speed Limit 1
0
None
0
Fcn. No. 58
Description
Default
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter (thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter (tens/units)
Read Only
Secure Auxiliary Hourmeter (thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by user (tens/units)
0 to 99
Lift truck number assigned by user (thou-
sands/hundreds)
100 to 9900
16
2200 SRM 596
Register Parameters Tables
Table 5. EV-T100 Parameters - E2.00-3.20XM (72 to 80V) (Traction Card Type JY/NY) Low Energy
Consumption (9-inch Motor With Regenerative Braking and Without Field Weakening)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
1
Stored Statue Code
0
1
-
0
1
/255
-
2
Creep Speed
0
5%
0/255
5% to 15%
3
Controlled Acceleration
and 1A Time
30
2.6 sec
8/255
0.77 to 21.5 seconds
4
Current Limit (C/L)
255
Max.
amp
0/130
5
Plugging Distance (Current)
80
388 amp
0/55
200 to 411 amperes
6
1A Drop-Out Current
12
489 amp
0/250
2
450 to 1260 amperes
7
Field Weakening Pick-Up
(Current)
0
N/A
Not
Applicable
Not Applicable
8
Field Weakening Drop-Out
(Current)
0
65 amp
0/70
65 to 293 amperes
9
Regenerative Braking
Current Limit
100
220 amp
0/110
75 to 235 amperes
10
Regenerative Braking Start
(% ON time)
10
3.70%
0/255
0% to 95% SCR ON time
11
Speed Limit 1 (maximum
motor speed, Voltage with NC
switch open) (Not Used)
0
96% of
batt.
volts
0/180
96% to 0% of battery
voltage
12
Speed Limit 2 (maximum
motor speed, Voltage with NC
switch open) (Not Used)
0
96% of
batt.
volts
0/180
96% to 0% of battery
voltage
13
Speed Limit 3 (maximum
motor speed, Voltage with
NC switch open)
120
64% of
batt.
volts
0/180
96% to 0% of battery
voltage
14
Internal Resistance
Compensation
12
3
-
5/25
-
15
Battery Volts
75
72 V
70/80
72 volt operation
15
Battery Volts
85
80 V
81/183
80 volt operation
16
Pedal Position Plugging
40
228 amp
0/85
100 to 373 amperes
17
Card Type Selection
42
Plugging
Regen.
FW
40
42
44
Select control card with
correct functions:
Regenerative Braking
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
17
Register Parameters Tables
2200 SRM 596
Table 5. EV-T100 Parameters - E2.00-3.20XM (72 to 80V) (Traction Card Type JY/NY) Low Energy
Consumption (9-inch Motor With Regenerative Braking and Without Field Weakening) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
18
Steering Pump Time Delay
(Seat Switch)
25
14 sec
0/128
1.5 sec to 65 seconds
19
Maintenance Alert (hours)
99
0 to 99
20
Maintenance Alert (hours)
99
100 to 9900
21
Maintenance Speed Limit
0
None
None/0
None to 180
22
Mode Reference (Reference
register for the instrument
panel display when the
battery is connected.)
-
None
None
-
23
Hourmeter (minutes)
0
24
Hourmeter (seconds)
0
25
Monitor Register
0
-
None
(Temporary storage
register.)
26
Monitor Register
0
-
None
(Temporary storage
register.)
27
Stop Plugging Set Point
65
9.7%
20/100
13.4 to 6.8%
28
Fault Count Pointer
(Must be reset to zero to
clear Status Codes)
-
-
None
(Temporary storage
register that points to
location of last recorded
fault.)
29
Set Hourmeter (tens/units)
0
0
0-99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
3
Average value for most batteries. See procedure for more accurate value.
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
Function Numbers 31 through 47 can be read and cleared with a Handset. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can
only be reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62 enable the lift truck to be set to four performance levels by the operator.
(If the customer does not want this function available to the operator, a service person can set all four levels
to the same setting.) Each time the operator pushes the button on the instrument panel, the performance
level will increase by one step. At the maximum (rabbit) level, the performance levels will begin at the
lowest (turtle) level again.
18
2200 SRM 596
Register Parameters Tables
Table 5. EV-T100 Parameters - E2.00-3.20XM (72 to 80V) (Traction Card Type JY/NY) Low Energy
Consumption (9-inch Motor With Regenerative Braking and Without Field Weakening) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
MODE 1
48
Controlled Acceleration
60
5.0 sec
8/288
255
49
FW Pick-Up Current
0
None
0
None
50
Speed Limit 1
120
64%
Fcn. No. 54
180
51
Not Used
MODE 2
52
Controlled Acceleration
40
3.5 sec
8/255
Fcn. No. 48
53
FW Pick-Up Current
0
None
0
None
54
Speed Limit 1
0
None
None
180
55
Not Used
MODE 3
56
Controlled Acceleration
30
2.6 sec
8/255
Fcn. No. 52
57
FW Pick-Up Current
0
None
None
None
58
Speed Limit 1
0
None
Fcn. No. 62
Fcn. No. 54
59
Not Used
MODE 4
60
Controlled Acceleration
20
1.8 sec
8/255
Fcn. No. 56
61
FW Pick-Up Current
0
None
None
None
62
Speed Limit 1
0
None
0/180
Fcn. No. 58
Description
Default
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter (thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter (tens/units)
Read Only
Secure Auxiliary Hourmeter (thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
19
Register Parameters Tables
2200 SRM 596
Table 5. EV-T100 Parameters - E2.00-3.20XM (72 to 80V) (Traction Card Type JY/NY) Low Energy
Consumption (9-inch Motor With Regenerative Braking and Without Field Weakening) (Continued)
Description
Default
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by user (tens/units)
0 to 99
Lift truck number assigned by user (thou-
sands/hundreds)
100 to 9900
Table 6. EV-T100 Parameters - All Lift Trucks (36 to 80 volts) (Hydraulic Pump Card Type LP)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
1
Stored Statue Code
0
1
-
0
1
/255
-
2
Internal Resistance
Compensation Start
10
65 amp
0/255
3
Controlled Acceleration
50
1.04 sec
25/150
0.52 to 3.1 sec
4
Current Limit (C/L)
255
Max.
amp
0/255
Max. amperes
5
Not Used
6
Not Used
7
Controlled Acceleration
Compensation
15
8
Not Used
9
Not Used
10
Not Used
11
Speed Limit 1
70
13 volts
30/70
11 to 26 volts
12
Speed Limit 2
80
21 volts
30/70
11 to 26 volts
13
Speed Limit 3
165
Maxi-
mum
volts
30/255
11 to maximum volts
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
20
2200 SRM 596
Register Parameters Tables
Table 6. EV-T100 Parameters - All Lift Trucks (36 to 80 volts) (Hydraulic
Pump Card Type LP) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
14
Speed Limit 4
165
Maxi-
mum
volts
30/255
11 to maximum volts
15
Not Used
16
Internal Resistance
Compensation
10
2.28 volts
17
Card Type Selection with
BDI Low Function
54 High Current Limit with lockout function
57 High Current Limit with lockout function
62 High Current Limit with lockout function
17
Card Type Selection without
BDI Function
36 High Current Limit without lockout function
40 High Current Limit without lockout function
44 High Current Limit without lockout function
18
Not Used
19
Not Used
20
Not Used
21
Not Used
22
Not Used
23
Not Used
24
Not Used
25
Monitor Register
0
-
None
(Temporary storage
register.)
26
Monitor Register
0
(Temporary storage
register.)
27
Not Used
28
Fault Count Pointer
(Must be reset to zero to
clear Status Codes)
-
-
None
(Temporary storage
register that points to
location of last recorded
fault.)
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
21
Register Parameters Tables
2200 SRM 596
Table 6. EV-T100 Parameters - All Lift Trucks (36 to 80 volts) (Hydraulic
Pump Card Type LP) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
29
Set Hourmeter (tens/units)
0
0
0-99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
1
Any number other than "zero" can be read as a possible fault.
2
Settings greater than 250 will disable the 1A Drop-Out function
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
Function Numbers 31 through 47 can be read and cleared with a Handset. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can
only be reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62 enable the lift truck to be set to four performance levels by the operator.
(If the customer does not want this function available to the operator, a service person can set all four levels
to the same setting.) Each time the operator pushes the button on the instrument panel, the performance
level will increase by one step. At the maximum (rabbit) level, the performance levels will begin at the
lowest (turtle) level again.
MODE 1
48
Controlled Acceleration
120
2.5 sec
25
(0.52 sec)
150 (3.1 sec)
49
Speed Limit 2
66
25 volts
60 (22 volts)
106 (40 volts)
50
Speed Limit 3
133
50 volts
70 (26 volts)
255 (Maximum volts)
51
Not Used
MODE 2
52
Controlled Acceleration
80
1.7 sec
25
(0.52 sec)
150 (3.1 sec)
53
Speed Limit 2
80
30 volts
60 (22 volts)
106 (40 volts)
54
Speed Limit 3
155
58 volts
70 (26 volts)
255 (Maximum volts)
55
Not Used
MODE 3
56
Controlled Acceleration
50
1.04 sec
25
(0.52 sec)
150 (3.1 sec)
57
Speed Limit 2
101
38 volts
60 (22 volts)
106 (40 volts)
58
Speed Limit 3
255
Maxi-
mum
volts
70 (26 volts)
255 (Maximum volts)
22
2200 SRM 596
Register Parameters Tables
Table 6. EV-T100 Parameters - All Lift Trucks (36 to 80 volts) (Hydraulic
Pump Card Type LP) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
59
Not Used
MODE 4
60
Controlled Acceleration
25
25
(0.52 sec)
150 (3.1 sec)
61
Speed Limit 2
106
40 volts
60 (22 volts)
106 (40 volts)
62
Speed Limit 3
179
67 volts
70 (26 volts)
255 (Maximum volts)
Description
Default
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter (thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter (tens/units)
Read Only
Secure Auxiliary Hourmeter (thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by user
Lift truck number assigned by user
23
Register Parameters Tables
2200 SRM 596
Table 7. EV-T100 Parameters - All Lift Trucks (24 to 80 volts) (Hydraulic Pump Card Type HP)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
1
Stored Statue Code
0
1
-
0
1
/255
-
2
Internal Resistance
Compensation Start
10
65 amp
0/255
3
Controlled Acceleration
50
1.04 sec
25/150
0.52 to 3.1 sec
4
Current Limit (C/L)
255
Max.
amp
0/255
Max. amperes
5
Not Used
6
Not Used
7
Controlled Acceleration
Compensation
15
8
Not Used
9
Not Used
10
Not Used
11
Speed Limit 1
70
26 volts
60/106
22 to 40 volts
12
Speed Limit 2
80
30 volts
60/106
22 to 40 volts
13
Speed Limit 3
255
Maxi-
mum
volts
60/255
22 to maximum volts
14
Speed Limit 4
255
Maxi-
mum
volts
60/255
22 to maximum volts
15
Not Used
16
Internal Resistance
Compensation
10
2.28 volts
17
Card Type Selection with
BDI Low Function
54 High Current Limit with lockout function
57 High Current Limit with lockout function
62 High Current Limit with lockout function
17
Card Type Selection without
BDI Function
36 High Current Limit without lockout function
40 High Current Limit without lockout function
44 High Current Limit without lockout function
18
Not Used
19
Not Used
20
Not Used
21
Not Used
22
Not Used
1
Any number other than "zero" can be read as a possible fault.
24
2200 SRM 596
Register Parameters Tables
Table 7. EV-T100 Parameters - All Lift Trucks (24 to 80 volts) (Hydraulic
Pump Card Type HP) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Min/Max
Parameter
Value
(Min/Max)
23
Not Used
24
Not Used
25
Monitor Register
0
-
None
(Temporary storage
register.)
26
Monitor Register
0
(Temporary storage
register.)
27
Not Used
28
Fault Count Pointer
(Must be reset to zero to
clear Status Codes)
-
-
None
(Temporary storage
register that points
to location of last
recorded fault.)
29
Set Hourmeter (tens/units)
0
0
0-99
30
Set Hourmeter
(thousands/hundreds)
0
0
100 to 9900
1
Any number other than "zero" can be read as a possible fault.
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
Function Numbers 31 through 47 can be read and cleared with a Handset. These registers store the fault
codes and other data that the controller senses during the operation of the lift truck. These registers can
only be reset to zero. The PC software program automatically resets these registers to zero.
Function Numbers 48 through 62 enable the lift truck to be set to four performance levels by the operator.
(If the customer does not want this function available to the operator, a service person can set all four levels
to the same setting.) Each time the operator pushes the button on the instrument panel, the performance
level will increase by one step. At the maximum (rabbit) level, the performance levels will begin at the
lowest (turtle) level again.
MODE 1
48
Controlled Acceleration
120
2.5 sec
25
(0.52 sec)
150 (3.1 sec)
49
Speed Limit 2
66
25 volts
60 (22 volts)
106 (40 volts)
50
Speed Limit 3
133
50 volts
70 (26 volts)
255 (Maximum volts)
51
Not Used
MODE 2
52
Controlled Acceleration
80
1.7 sec
25
(0.52 sec)
150 (3.1 sec)
53
Speed Limit 2
80
30 volts
60 (22 volts)
106 (40 volts)
25
Register Parameters Tables
2200 SRM 596
Table 7. EV-T100 Parameters - All Lift Trucks (24 to 80 volts) (Hydraulic
Pump Card Type HP) (Continued)
Default
Permitted Range
Fcn.
No.
Description
Factory
Parameter
Factory
Value
Minimum
Parameter
Maximum
Parameter
54
Speed Limit 3
160
60 volts
70 (26 volts)
255 (Maximum volts)
55
Not Used
MODE 3
56
Controlled Acceleration
50
1.04 sec
25
(0.52 sec)
150 (3.1 sec)
57
Speed Limit 2
101
38 volts
60 (22 volts)
106 (40 volts)
58
Speed Limit 3
255
Maxi-
mum
volts
70 (26 volts)
255 (Maximum volts)
59
Not Used
MODE 4
60
Controlled Acceleration
25
25
(0.52 sec)
150 (3.1 sec)
61
Speed Limit 2
106
40 volts
60 (22 volts)
106 (40 volts)
62
Speed Limit 3
255
Maxi-
mum
volts
70 (26 volts)
255 (Maximum volts)
Description
Default
The following registers store information used by the controller and the HYTECH software and do not have
function numbers assigned.
Not Used
Secure Hourmeter (tens/units)
Read Only
Secure Hourmeter (thousands/hundreds)
Read Only
Secure Auxiliary Hourmeter (tens/units)
Read Only
Secure Auxiliary Hourmeter (thousands/hundreds)
Read Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Reserved for use by GE
GE Use Only
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
Lift Truck Serial Number
26
2200 SRM 596
Register Parameters Tables
Table 7. EV-T100 Parameters - All Lift Trucks (24 to 80 volts) (Hydraulic
Pump Card Type HP) (Continued)
Description
Default
Lift Truck Serial Number
Lift Truck Serial Number
Lift truck number assigned by user
Lift truck number assigned by user
27
NOTES
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
28
TECHNICAL PUBLICATIONS