Wyznaczanie współczynnika przepływu w zwężkach pomiarowych dla cieczy



pi srednica
















3.14159265358979 0.02735




















Δp [mm Hg] V [m3/h] t [s] h [m] m [kg/s] Δp [Pa] alfa moduł V [m3/s] w0 [m/s] Re
580 16 4.4 0.1 5.0141 71572.22 0.7133 0.299 5.0141E-03 8.535 233421.97
514 15 4.9 0.1 4.5024 63427.80 0.6804 0.299 4.5024E-03 7.664 209603.40
450 14 5.2 0.1 4.2427 55530.17 0.6853 0.299 4.2427E-03 7.222 197510.90 śr. rury [m]
390 13 5.8 0.1 3.8038 48126.15 0.6599 0.299 3.8038E-03 6.475 177078.74 0.05
330 12 6.0 0.1 3.6770 40722.13 0.6935 0.299 3.6770E-03 6.259 171176.11
278 11 6.7 0.1 3.2928 34305.31 0.6767 0.299 3.2928E-03 5.605 153292.04
230 10 7.0 0.1 3.1517 28382.09 0.7120 0.299 3.1517E-03 5.365 146722.38
204 9 7.8 0.1 2.8284 25173.68 0.6785 0.299 2.8284E-03 4.814 131673.93
146 8 9.0 0.1 2.4513 18016.46 0.6951 0.299 2.4513E-03 4.172 114117.41
108 7 10.4 0.1 2.1213 13327.24 0.6994 0.299 2.1213E-03 3.611 98755.45
104 6 12.8 0.1 1.7236 12833.64 0.5791 0.299 1.7236E-03 2.934 80238.80
50 5 15.4 0.1 1.4326 6170.02 0.6942 0.299 1.4326E-03 2.438 66691.99







































srednica

















0.03183




















Δp [mm Hg] V [m3/h] t [s] h [m] m [kg/s] Δp [Pa] alfa moduł V [m3/h] w0 [m/s] Re
310 16 4.4 0.1 5.0141 38254.12 0.7204 0.405 5.0141E-03 6.301 200568.36
274 15 4.9 0.1 4.5024 33811.70 0.6881 0.405 4.5024E-03 5.658 180102.20
242 14 5.2 0.1 4.2427 29862.89 0.6899 0.405 4.2427E-03 5.332 169711.69
214 13 5.8 0.1 3.8038 26407.68 0.6578 0.405 3.8038E-03 4.780 152155.31
178 12 6.0 0.1 3.6770 21965.27 0.6972 0.405 3.6770E-03 4.621 147083.46
152 11 6.7 0.1 3.2928 18756.86 0.6756 0.405 3.2928E-03 4.138 131716.54
126 10 7.0 0.1 3.1517 15548.45 0.7103 0.405 3.1517E-03 3.961 126071.54
98 9 7.8 0.1 2.8284 12093.24 0.7228 0.405 2.8284E-03 3.555 113141.13
80 8 9.0 0.1 2.4513 9872.03 0.6933 0.405 2.4513E-03 3.081 98055.64
60 7 10.4 0.1 2.1213 7404.02 0.6928 0.405 2.1213E-03 2.666 84855.84
44 6 12.8 0.1 1.7236 5429.62 0.6573 0.405 1.7236E-03 2.166 68945.37
32 5 15.4 0.1 1.4326 3948.81 0.6406 0.405 1.4326E-03 1.800 57305.25















srednica










0.03355




















Δp [mm Hg] V [m3/h] t [s] h [m] m [kg/s] Δp [Pa] alfa moduł V [m3/h] w0 [m/s] Re
224 16 4.4 0.1 5.0141 27641.69 0.7628 0.450 5.0141E-03 5.672 190285.87
208 15 4.9 0.1 4.5024 25667.28 0.7108 0.450 4.5024E-03 5.093 170868.94
182 14 5.2 0.1 4.2427 22458.87 0.7161 0.450 4.2427E-03 4.799 161011.12
162 13 5.8 0.1 3.8038 19990.86 0.6805 0.450 3.8038E-03 4.303 144354.80
134 12 6.0 0.1 3.6770 16535.65 0.7233 0.450 3.6770E-03 4.159 139542.97
116 11 6.7 0.1 3.2928 14314.44 0.6961 0.450 3.2928E-03 3.725 124963.85
96 10 7.0 0.1 3.1517 11846.44 0.7324 0.450 3.1517E-03 3.565 119608.26
76 9 7.8 0.1 2.8284 9378.43 0.7387 0.450 2.8284E-03 3.199 107340.75
60 8 9.0 0.1 2.4513 7404.02 0.7206 0.450 2.4513E-03 2.773 93028.65
46 7 10.4 0.1 2.1213 5676.42 0.7122 0.450 2.1213E-03 2.400 80505.56
34 6 12.8 0.1 1.7236 4195.61 0.6730 0.450 1.7236E-03 1.950 65410.77
12 5 15.4 0.1 1.4326 1480.80 0.9416 0.450 1.4326E-03 1.620 54367.39



























srednica










0.03555




















Δp [mm Hg] V [m3/h] t [s] h [m] m [kg/s] Δp [Pa] alfa moduł V [m3/h] w0 [m/s] Re
134 16 4.4 0.1 5.0141 16535.65 0.8784 0.506 5.0141E-03 5.051 179580.62
120 15 4.9 0.1 4.5024 14808.05 0.8335 0.506 4.5024E-03 4.536 161256.06
104 14 5.2 0.1 4.2427 12833.64 0.8437 0.506 4.2427E-03 4.274 151952.83
92 13 5.8 0.1 3.8038 11352.84 0.8042 0.506 3.8038E-03 3.832 136233.57
98 12 6.0 0.1 3.6770 12093.24 0.7532 0.506 3.6770E-03 3.704 131692.45
62 11 6.7 0.1 3.2928 7650.82 0.8481 0.506 3.2928E-03 3.317 117933.54
52 10 7.0 0.1 3.1517 6416.82 0.8863 0.506 3.1517E-03 3.175 112879.24
42 9 7.8 0.1 2.8284 5182.82 0.8851 0.506 2.8284E-03 2.850 101301.89
36 8 9.0 0.1 2.4513 4442.41 0.8285 0.506 2.4513E-03 2.470 87794.97
26 7 10.4 0.1 2.1213 3208.41 0.8437 0.506 2.1213E-03 2.137 75976.41
18 6 12.8 0.1 1.7236 2221.21 0.8239 0.506 1.7236E-03 1.736 61730.84
12 5 15.4 0.1 1.4326 1480.80 0.8387 0.506 1.4326E-03 1.443 51308.75

























Wyszukiwarka

Podobne podstrony:
Wyznaczanie współczynnika przepływu w zwężkach pomiarowych dla cieczy
Wyznaczanie współczynnik przepływu w zwężkach pomiarowych dla cieczy, pwr biotechnologia(I stopień),
Wyznaczanie współczynnika przepływu w zwężkach pomiarowych dla cieczy
Wyznaczanie współczynnika przepływu w zwężkach pomiarowych dla cieczy
sprawozdanie tc cz.1 , Wyznaczenie współczynnika lepkości dynamicznej i kinematycznej badanej cieczy
Wyznaczanie współczynnika przepływu alfa., Laboratorium mechaniki płynów
Wstęp 60, Studia, Pracownie, I pracownia, 60 Wyznaczanie współczynnika załamania światła ciał stałyc
Wyznaczanie współczynnika załamania światła z pomiarów kąta z, Nazwisko Kraczkowski
Wyznaczanie współczynnika załamania światła z pomiarów kąta załamania oraz kąta ugięcia, Pollub MiBM
Sprawozdanie 60, Studia, Pracownie, I pracownia, 60 Wyznaczanie współczynnika załamania światła ciał
Wyznaczanie współczynnik załamania światła z pomiarów kąta załamania oraz kąta granicznego CZURYŁ
Wzorcowanie zwężek pomiarowych dla cieczy
Wyznaczanie współczynnika załamania światła z pomiarów kąta załamania oraz kąta granicznego MAZUREK
ćw 76 wyznaczanie współczynnika pochłaniania promieniowania gamma dla różnych materiałów
wyznaczanie współczynnika strat lokalnych energi przy przepływie cieczyw ukaładach hydraulicznych

więcej podobnych podstron