PNOZ EX GB

background image

1-1

1

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ Ex

Emergency stop relay and safety
gate monitor in accordance with
VDE 0113-1, 11/98, EN 60204-1,
12/97 and IEC 204-1, 11/98.

Features

● AC operating voltage only
● For Ex-protection [EEx ia] II B(C)
● Dual-channel operation only
● Monitored manual or automatic

reset can be selected

Approvals

Technical Details

PNOZ Ex

Electrical Data

Supply Voltage

AC: 115, 120, 230 V

Tolerance

85 ... 110 %

Power Consumption

Approx. 9 VA

Voltage and Current at the Input and

6 VDC/ 25 mA

Reset Circuits and Feedback Control Loop

Switching Capability in accordance with

EN 60947-4-1, 10/91

AC1:

240 V/4 A/1000 VA

DC1: 24 V/2 A/50 W

EN 60947-5-1, 10/91

AC15: 230 V/4 A; DC13: 24 V/5A

(DC13: 6 cycles/min.)

Output Contacts

3 safety contacts (N/O)

1 auxiliary contact (N/C)

in intrinsically safe area:

2 auxiliary contacts (N/O)

Contact Material

AgSnO

2

in intrinsically safe area:

Rhodium

Contact Fuse Protection

6 A quick or 4 A slow

(EN 60947-5-1, 10/91)

Times

Delay-on Energisation

Approx. 150 ms

Delay-on De-energisation K1/2

Approx. 50 ms

Delay-on De-energisation K3

Approx. 90 ms

Switch-on Delay

Approx. 150 ms

Simultaneity channel 1/2

Approx. 90 ms or

¥

Max. Supply Interruption before De-energisation

Approx. 35 ms

Environmental Data

Ambient Temperature

-20 ... +55 °C

Mechanical Data

Maximum Cross Section of

2 x 1.5 mm

2

External Condutors

Single-core or multi-core

with crimp connectors

Dimensions (H x W x D)

75 x 112.5 x 121 mm

Weight

727 g

Description

● 112.5 mm P-93 housing, DIN Rail

mounting

● Positive-guided relay outputs:

– 3 safety contacts (N/O)
– 1 auxiliary contact (N/O) for

intrinsically safe area

– 1 auxiliary contact (N/O) for

fusing in the intrinsically safe
area

– 1 auxiliary contact (N/C) for

the non-intrinsically safe area

● Connections for

– E-STOP button
– safety gate limit switch
– reset button

● LEDs for power, channel 1,

channel 2, fuse, ch.1/ch.2 on and
fault

● Increase in the number of

safety contacts available by
connecting expander modules.

Operating Modes

● Dual-channel operation
● Manual reset
● Monitored manual reset

NSG-D-2-061-10/03

PNOZ Ex

background image

1

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de

K2

K3

K1

K1

K2 K3

K3

K3

K1

K2

~

K4

S11

S52

S12 S21 S22 S33 S34 Y36 Y37

A2

A1

-

+

K8

53 54

K9*

63 64

Y1
Y2

24

14

34 42

K1

K2

K3

K5

K6

K7

41

33

23

13

K7

K4

K5

K6

K8

K2

K7

F1

~

-

+

K9

U

B

Feedback
control loop

Safety
contacts

Auxiliary
contact

Intrinsically safe area [EEx ia]

* K9: Signal
contact for
fusing

Auxiliary contacts

Input circuits

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ Ex

Internal Wiring Diagram

External Wiring

● Example 1
Dual-channel E-STOP wiring with
manual reset in the non-intrinsically
safe area.

● Example 2
Dual-channel E-STOP wiring with
manual reset in the intrinsically safe
area.

S11 S21

Y1

S12

S12

S34

Y2

S22

Y36

S52

S3

S1

Intrinsically safe area

S11 S21

Y1

S12

S12

S34

Y2

S22

Y36

S52

S1

S3

Intrinsically safe area

● Example 4
Dual-channel E-STOP wiring with
monitored manual reset in the
intrinsically safe area.

S11 S21

S33

S12

S12

S34 Y37

S22

Y36

S52

Y1

Y2

S1

S3

Intrinsically safe area

● Example 3
Dual-channel E-STOP wiring with
monitored manual reset in the non-
intrinsically safe area.

S11 S21

Y1

S12

S12

S34

Y2

S22

Y36

S52

S33

Y37

S1

S3

Intrinsically safe area

● Example 5
Dual-channel safety gate control with
position monitoring in the intrinsically
safe area.

S11

S33

S34

S52

S1

S2

Y1

S12
S11

S12

Y2

Intrinsically safe area

S21

S22

– Key

S1/2:

E-STOP or safety gate switch

S3:

Reset button

Switch operated

Gate open

Gate closed

● Increase in safety contacts
The number of output contacts can
be increased by using expander
modules or relays/contactors with
positive-guided contacts.

14

K4

K5

13

Y1

Y2

K4

K5

1L1

1L2

NSG-D-2-061-10/03

background image

1-3

1

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ EX

NSG-D-2-061-10/03

General Technical Data

Unless stated otherwise in the technical details for the specific unit

Electrical Data

Frequency Range AC

50 ... 60 Hz

Residual Ripple DC

160 %

Contact Material

AgSnO

2

Continuous Duty

100 %

Environmental Data

EMC

EN 50081-1, 01/92, EN 50082-2, 03/95

Vibration in accordance with

Frequency: 10 ... 55 Hz,

EN 60068-2-6, 04/95

Amplitude: 0.35 mm

Climatic Suitability

DIN IEC 60068-2-3, 12/86

Airgap Creepage

DIN VDE 0110 part 1, 04/97

Ambient Temperature

-10 ... +55 °C

Storage Temperature

-40 ... +85 °C

Mechanical Data

Torque Setting on Connection Terminals

0.6 Nm (screws)

Mounting Position

Any

Housing Material

Thermoplast Noryl SE 100

Protection

Mounting: IP 54

Housing: IP 40

Terminal Range: IP 20

The units were tested in accordance with the relevant standards current at
the time of development.

Order References

Type

U

B

Order No.

PNOZ Ex

115 V AC

774 104

PNOZ Ex

120 V AC

774 105

PNOZ Ex

230 V AC

774 100

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de


Wyszukiwarka

Podobne podstrony:
pnoz x3p gb B5VW75QW7OGZ3YAVF6G43JUJXVPZSFBDAWURFWI
pnoz xe1 gb[1] OHVH62VRNRX27UG45CP4SMHI65HT275IHJKNDPA
PNOZ XV2P GB
PNOZ X3P GB
PNOZ X2P GB
PNOZ 16SP GB
PNOZ XE2 GB
PNOZ XV2 1 GB
PNOZ XV3 GB
PNOZ E1P GB
PNOZ 2VQ GB
PNOZ XM1 GB
PNOZ X2C GB
PNOZ X3 1 GB
PNOZ 11 GB
PNOZ 16 GB
PNOZ X13 GB

więcej podobnych podstron