PNOZ X2 5P GB

background image

1

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ X2.5P

Emergency stop relay and safety
gate monitor to VDE 0113 Part 1,
11/98 and EN 60204-1, 12/97

Features

● Dual-channel operation which

detects shorts across the input
contacts

● Supply voltage: 24 VDC

● 2 safety contacts

● 1 semiconductor output for PLC

● Plug-in connection terminals

Approvals

Technical details

PNOZ X2.5P

Electrical data

Supply voltage

DC: 24 V

Tolerance

85 ... 110 %

Power consumption

approx. 2 W

Voltage and current at input circuit

Single-channel 24 VDC, 50 mA

Dual-channel: 24 VDC, 25 mA

Switching capability to

EN 60947-4-1, 02/01

AC1:

240 V/6 A/1500 VA

DC1:

24 V/4 A/100 W

EN 60947-5-1, 11/97

AC15:

230 V/5 A; DC13: 24 V/4A

(DC13: 6 switching operations/min)

Output contacts

2 safety contacts (N/O)

Contact fuse protection

6 A quick or 4 A slow

to EN 60947-5-1, 11/97

Semiconductor outputs

24 VDC/100 mA, NPN short-circuit-proof

external power supply

24 VDC ±20 %

Timers

Switch-on delay

Automatic reset: max. 200 ms

Manual reset: max. 55 ms

Delay-on de-energisation

Max. 30 ms

Recovery time

Approx. 1 s

Simultaneity channel 1/2

¥

Supply interruption before de-energisation Approx. 10 ms

Mechanical data

Max. cros-section of external conductor

Single-core

Flexible without crimp connector:

0.2 ... 2.5 mm

2

Flexible with crimp connector:

0.25 ... 2.5 mm

2

Multi-core (2 conductors of the same

Flexible with crimp connector without

cross-section)

plastic sleeve: 0.25 ... 1 mm

2

Flexible with TWIN crimp connector with

plastic sleeve: 0.5 ... 1.5 mm

2

Torque setting for connection terminals

0.5 ... 0.6 Nm (screws)

Dimensions (H x W x D)

94 x 22.5 x 121 mm

Weight

190 g

Description

● 22.5 mm P-99 housing, DIN rail

mounting

● Positive-guided relay outputs:

2 safety contacts (N/O)

● 1 semiconductor output

● Connections for

- emergency stop button or

safety gate limit switch

- reset button

● Detects shorts across the input

contacts

● LEDs for switch status, channel

1/2 and semiconductor output

● Increase in the number of safety

contacts available by connecting
expander modules

Operating modes

● Single-channel operation

● Dual-channel operation

● Automatic reset

● Manual reset

Pilz GmbH & Co., Felix-Wankel-Strasse 2, 73760 Ostfildern, Germany

NSG-D-2-290-03/03

Telefon +49 (7 11) 34 09-0,Telefax +49 (7 11) 34 09-1 33, E-mail: pilz.gmbh@pilz.de

PNOZ X2.5P

PNOZ X2.5P

background image

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ X2.5P

Internal wiring diagram

External wiring

● Example 1
Single-channel E-STOP wiring with
automatic reset.

● Example 4
Dual-channel safety gate control with
automatic reset.

S34

S33

S21

S32

S22
S31

S1

S1

S2

S12

S11

● Example 2
Single-channel E-STOP wiring with
manual reset

S31

S32

S34

S22

S33

S21

S1

S3

S12

S11

● Example 3
Dual-channel E-STOP wiring with
manual reset

K3

S33

S34

K4

K3

K4

23

24

L1

N

● Increase in safety contacts
The number of output contacts can
be increased by using expander
modules or relays/contactors with
positive-guided contacts.

Gate open

Switch operated

Gate closed

S1/S2: E-STOP or safety gate

switch

S3:

Reset button

- Key

S31

S32

S34

S22

S33

S21

S11

S12

S1

S3

S31

S32

S34

S22

S33

S21

S11

S12

S1

Pilz GmbH & Co., Felix-Wankel-Strasse 2, 73760 Ostfildern, Germany

NSG-D-2-290-03/03

Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-mail: pilz.gmbh@pilz.de

● Example 5
If a fault occurs, the PLC input goes
high

Y11

Y12

A1 (L+)

A2 (L-)

S22

S31

S21

S32

S33

23

24

K1

K2

33

34

S34

Start

Unit

Start

Unit

S11 S12

&

Input
circuit

Reset circuit/
feetback
control loop

Input
circuit

Safety
contacts

Input circuit

E0.0

+ 24V

0V

PLC

PNOZ X2.5P

24

Y12

A2

S32 S21 S22

34

S31

Y11 23

33

S11

S34

S33

A1

S12

● Example 6
If a fault occurs, the PLC input goes
low

E0.0

+ 24V

0V

PLC

PNOZ X2.5P

24

Y12

A2

S32 S21 S22

34

S31

Y11 23

33

S11

S34

S33

A1

S12

background image

1

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ X2.5P

Pilz GmbH & Co., Felix-Wankel-Strasse 2, 73760 Ostfildern, Germany

NSG-D-2-290-03/03

Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-mail: pilz.gmbh@pilz.de

General data

Unless stated otherwise in the technical details for the specific

unit

Electrical data

AC frequency range

50 ... 60 Hz

DC residual ripple

160 %

Contact material

AgSnO

2

Continuous duty

100 %

Environmental data

EMC

EN 50081-1, 01/92, EN 61000-6-2, 03/00

Vibration to EN 60068-2-6, 01/00

Frequency: 10 ... 55 Hz,

Amplitude: 0.35 mm

Climatic suitability

DIN IEC 60068-2-3, 12/86

Airgap creepage

DIN VDE 0110-1, 04/97

Ambient temperature

-10 ... +55 °C

Storage temperature

-40 ... +85 °C

Mechanical data

Torque setting for connection terminals

0.6 Nm (screws)

Mounting position

Any

Housing material

Thermoplastic Noryl SE 100

Protection types

Mounting: IP 54

Housing: IP 40

Terminal area: IP 20

The units were tested in accordance with the standards applicable at the
time of development.

Order reference

Type

U

B

Order number

PNOZ X2.5P

24 VDC

777 308


Wyszukiwarka

Podobne podstrony:
pnoz x2 8p gb N6UOWRFWK2SGXLCONW7K7QZNBF6QBZQMGRHLKEQ
pnoz x2 7p gb TFLL2KJYRRWLH57VUHMA4GNT5EFCG5Y7YNKDHWI
PNOZ X2 3P GB
PNOZ X2 1VP GB
PNOZ X2 4V gb
PNOZ X2 7P GB
PNOZ X2 GB
PNOZ E1 1P GB
PNOZ XV3 1P GB
PNOZ XV2 1P GB
PNOZ E3 1P gb
pnoz x3p gb B5VW75QW7OGZ3YAVF6G43JUJXVPZSFBDAWURFWI
pnoz xe1 gb[1] OHVH62VRNRX27UG45CP4SMHI65HT275IHJKNDPA
PNOZ EX GB
PNOZ XV2P GB
PNOZ X3P GB
PNOZ X2P GB

więcej podobnych podstron