FIELD SERVICE BULLETIN
FSB Number: LVCCFSB2005-259
Author: Rajesh Verma
Date: August 9, 2005
Total No. of Pages: 2
Subject: GSM V220 FM on Display Flex and PCB Display Connector
Phone Models: GSM V188 and V220
Level of Repair: 2
Problem
Service is aware of an issue, identified from the field, on the GSM V188 and V220.
Some units, returned with customer complaints of No Turn On or No/Intermittent Main
Display were found to be caused by poor connection between the Display Flex and the
PCB Display connector. Analysis revealed, this issue is caused by residue left on
Display Flex connector during brushing process. See Figures 1 and 2 below for
example.
V188- 30 pin connector
V220- 40 pin connector
Figure 1: Residue on connector Figure 2: Enlarged view of v220 Display Flex
Solution
MFS, the Flex supplier implemented the following corrective actions from March 28,
2005 and confirmed 0 DPPM after the implementation date.
1. Stop brushing process to remove flex residue from March 28, 2005
2. Change the cleaning solution on an hourly basis instead every shift.
3. Inspect 100% connector pin after post clean under magnifying scope.
MOTOROLA INTERNAL USE ONLY Page 1
Consumer Solutions & Support
US Competency Center
600 North US Highway 45
`
Libertyville, Illinois 60048
Website: gs.mot.com
Field Service Action
Customer Returns:
When servicing any No Turn On or No/Intermittent Main Display GSM V188 or V220
customer returns, with a Month of Manufacturer of April 2005 or earlier:
1. Power up the phone and verify the following symptoms: PCB current draw is
normal but the flip assembly does not power up (No Display).
a. If the unit PCB turns on and draws normal current but shows
no/intermittent Display symptoms then, disassemble the housing
b. Detach the Display Flex from the PCB Display connector
c. Clean the Display Flex and PCB Display connector using approved
cleaning procedures
d. Re-inspect connector under magnification to ensure pins are free from all
contaminants.
2. Reassemble the unit, and verify that customer complaint is fixed
3. If the unit displays the original failure symptom after cleaning the Display Flex
and PCB Display connector, then follow normal troubleshooting and repair
techniques to repair the unit per the customer complaint.
Note: Reseating or disconnecting/reconnecting the connector may temporarily
recover this failure mode, but failure has the potential to reoccur over-time.
Call Center Action:
When responding to customer inquires on the GSM V188/220 product, with various
customer complaints including No Turn On or No/Intermittent Main Display , please
direct the customer to have their phone serviced per this FSB.
Service Inventory:
Prior to use, make sure to clean with an approved cleaning method the Display Flex
connector on the Flex assembly manufactured before month of April 2005
Service Entry Code
Please ensure that repairs of this type are logged on the Service Link database as
follows:
Global M-Claims Codes:
Customer Complaint Code:
DIM01 (Display Main No Display)
TON01 (Can t switch phone on)
Problem Found Code:
DIM01 (Display Main No Display)
TON01 (No Turn on)
Reference Designator Code: J (Connector)
Repair Code: RAS02 (Reassemble Clean contact)
MOTOROLA INTERNAL USE ONLY Page 2
Wyszukiwarka
Podobne podstrony:
LVCCFSB2005 273 V220 Display Flex TearingLVCCFSB2005 304 GSM V220 DisplayLVCCFSB2004 208s V220 Antenna LooseLVCCFSB2005 6 V3 K Flex DamageLVCCFSB2006 1 V3 Wet Spot DisplayLVCCFSB20066 V3 P Flex CorrosionLVCCFSB2005 7s Ramless TMR Display (7287946Y01)White Main DisplayLVCCFSB2005 1s GSM V500R Display BrightnessLVCCFSB20060 V3i Torn K FlexUsing the Siemens S65 Displaydisplaydisplaydisplay settingsdisplayformatdisplay settingsdisplayformatdisplay (2)flex pierwsza aplikacja we flexwięcej podobnych podstron