LVCCFSB2005 259 V220 Display Flex


Consumer Solutions & Support
US Competency Center
600 North US Highway 45
`
Libertyville, Illinois 60048
Website: gs.mot.com
FIELD SERVICE BULLETIN
FSB Number: LVCCFSB2005-259
Author: Rajesh Verma
Date: August 9, 2005
Total No. of Pages: 2
Subject: GSM V220  FM on Display Flex and PCB Display Connector
Phone Models: GSM V188 and V220
Level of Repair: 2
Problem
Service is aware of an issue, identified from the field, on the GSM V188 and V220.
Some units, returned with customer complaints of  No Turn On or  No/Intermittent Main
Display were found to be caused by poor connection between the Display Flex and the
PCB Display connector. Analysis revealed, this issue is caused by residue left on
Display Flex connector during brushing process. See Figures 1 and 2 below for
example.
V188- 30 pin connector
V220- 40 pin connector
Figure 1: Residue on connector Figure 2: Enlarged view of v220 Display Flex
Solution
MFS, the Flex supplier implemented the following corrective actions from March 28,
2005 and confirmed 0 DPPM after the implementation date.
1. Stop brushing process to remove flex residue from March 28, 2005
2. Change the cleaning solution on an hourly basis instead every shift.
3. Inspect 100% connector pin after post clean under magnifying scope.
MOTOROLA INTERNAL USE ONLY Page 1
Consumer Solutions & Support
US Competency Center
600 North US Highway 45
`
Libertyville, Illinois 60048
Website: gs.mot.com
Field Service Action
Customer Returns:
When servicing any  No Turn On or  No/Intermittent Main Display GSM V188 or V220
customer returns, with a Month of Manufacturer of April 2005 or earlier:
1. Power up the phone and verify the following symptoms: PCB current draw is
normal but the flip assembly does not power up (No Display).
a. If the unit PCB turns on and draws normal current but shows
no/intermittent Display symptoms then, disassemble the housing
b. Detach the Display Flex from the PCB Display connector
c. Clean the Display Flex and PCB Display connector using approved
cleaning procedures
d. Re-inspect connector under magnification to ensure pins are free from all
contaminants.
2. Reassemble the unit, and verify that customer complaint is fixed
3. If the unit displays the original failure symptom after cleaning the Display Flex
and PCB Display connector, then follow normal troubleshooting and repair
techniques to repair the unit per the customer complaint.
Note: Reseating or disconnecting/reconnecting the connector may temporarily
recover this failure mode, but failure has the potential to reoccur over-time.
Call Center Action:
When responding to customer inquires on the GSM V188/220 product, with various
customer complaints including  No Turn On or  No/Intermittent Main Display , please
direct the customer to have their phone serviced per this FSB.
Service Inventory:
Prior to use, make sure to clean with an approved cleaning method the Display Flex
connector on the Flex assembly manufactured before month of April 2005
Service Entry Code
Please ensure that repairs of this type are logged on the Service Link database as
follows:
Global M-Claims Codes:
Customer Complaint Code:
DIM01 (Display Main  No Display)
TON01 (Can t switch phone on)
Problem Found Code:
DIM01 (Display Main  No Display)
TON01 (No Turn on)
Reference Designator Code: J (Connector)
Repair Code: RAS02 (Reassemble  Clean contact)
MOTOROLA INTERNAL USE ONLY Page 2


Wyszukiwarka

Podobne podstrony:
LVCCFSB2005 273 V220 Display Flex Tearing
LVCCFSB2005 304 GSM V220 Display
LVCCFSB2004 208s V220 Antenna Loose
LVCCFSB2005 6 V3 K Flex Damage
LVCCFSB2006 1 V3 Wet Spot Display
LVCCFSB20066 V3 P Flex Corrosion
LVCCFSB2005 7s Ramless TMR Display (7287946Y01)White Main Display
LVCCFSB2005 1s GSM V500R Display Brightness
LVCCFSB20060 V3i Torn K Flex
Using the Siemens S65 Display
display
display
display settings
displayformat
display settings
displayformat
display (2)
flex pierwsza aplikacja we flex

więcej podobnych podstron