Schemat stanowiska
1. komora pomiarowa
2. wentylator
3. walec kołowy
4. kątomierz
5.króciec pomiaru uśrednionego ciśnienia całkowitego
6. króciec pomiaru uśrednionego ciśnienia statycznego
7. mikromanometr z rurką
Tabela pomiarowo-obliczeniowa
Lp. | α | α[rad] | cosα | h | p | pcosα | |p| |
---|---|---|---|---|---|---|---|
1 | 0 | 0 | 1 | 5 | -40,4663 | -40,4663 | -5 |
2 | 10 | 0,174532925 | 0,984808 | -3 | 24,27975 | 23,91089 | 3 |
3 | 20 | 0,34906585 | 0,939693 | -17 | 137,5853 | 129,2878 | 17 |
4 | 30 | 0,523598776 | 0,866025 | -26 | 210,4245 | 182,233 | 26 |
5 | 40 | 0,698131701 | 0,766044 | -36 | 291,357 | 223,1924 | 36 |
6 | 50 | 0,872664626 | 0,642788 | -46 | 372,2895 | 239,3031 | 46 |
7 | 60 | 1,047197551 | 0,5 | -54 | 437,0355 | 218,5178 | 54 |
8 | 70 | 1,221730476 | 0,34202 | -58 | 469,4085 | 160,5472 | 58 |
9 | 80 | 1,396263402 | 0,173648 | -53 | 428,9423 | 74,48504 | 53 |
10 | 90 | 1,570796327 | 6,13E-17 | -52 | 420,849 | 2,58E-14 | 52 |
11 | 100 | 1,745329252 | -0,17365 | -49 | 396,5693 | -68,8635 | 49 |
12 | 110 | 1,919862177 | -0,34202 | -48 | 388,476 | -132,867 | 48 |
13 | 120 | 2,094395102 | -0,5 | -47 | 380,3828 | -190,191 | 47 |
14 | 130 | 2,268928028 | -0,64279 | -47 | 380,3828 | -244,505 | 47 |
15 | 140 | 2,443460953 | -0,76604 | -47 | 380,3828 | -291,39 | 47 |
16 | 150 | 2,617993878 | -0,86603 | -47 | 380,3828 | -329,421 | 47 |
17 | 160 | 2,792526803 | -0,93969 | -46 | 372,2895 | -349,838 | 46 |
18 | 170 | 2,967059728 | -0,98481 | -45 | 364,1963 | -358,663 | 45 |
19 | 180 | 3,141592654 | -1 | -46 | 372,2895 | -372,29 | 46 |
20 | 190 | 3,316125579 | -0,98481 | -47 | 380,3828 | -374,604 | 47 |
21 | 200 | 3,490658504 | -0,93969 | -47 | 380,3828 | -357,443 | 47 |
22 | 210 | 3,665191429 | -0,86603 | -47 | 380,3828 | -329,421 | 47 |
23 | 220 | 3,839724354 | -0,76604 | -47 | 380,3828 | -291,39 | 47 |
24 | 230 | 4,01425728 | -0,64279 | -47 | 380,3828 | -244,505 | 47 |
25 | 240 | 4,188790205 | -0,5 | -47 | 380,3828 | -190,191 | 47 |
26 | 250 | 4,36332313 | -0,34202 | -47 | 380,3828 | -130,099 | 47 |
27 | 260 | 4,537856055 | -0,17365 | -50 | 404,6625 | -70,2689 | 50 |
28 | 270 | 4,71238898 | -1,8E-16 | -52 | 420,849 | -7,7E-14 | 52 |
29 | 280 | 4,886921906 | 0,173648 | -53 | 428,9423 | 74,48504 | 53 |
30 | 290 | 5,061454831 | 0,34202 | -60 | 485,595 | 166,0833 | 60 |
31 | 300 | 5,235987756 | 0,5 | -53 | 428,9423 | 214,4711 | 53 |
32 | 310 | 5,410520681 | 0,642788 | -45 | 364,1963 | 234,1008 | 45 |
33 | 320 | 5,585053606 | 0,766044 | -35 | 283,2638 | 216,9926 | 35 |
34 | 330 | 5,759586532 | 0,866025 | -26 | 210,4245 | 182,233 | 26 |
35 | 340 | 5,934119457 | 0,939693 | -18 | 145,6785 | 136,893 | 18 |
36 | 350 | 6,108652382 | 0,984808 | -4 | 32,373 | 31,88118 | 4 |
Wykres rozkładu ciśnień
Obliczenia
wilgotność ϕ = 0,65
temperatura T = 22 [0C]
ciśnienie geometryczne 74,6 [mmHg]
średnica walca dw = 40 [mm]
przełożenie manometru α = 1 : 4,98
lepkość kinematyczna υ = 13,8*10-6 [m2/s]
warunki odniesienia:
temperatura Tn = 273 [K]
ciśnienie pn = 105 [Pa]
gęstość ρ = 1,276 [kg/m3]
dane dla powietrza wilgotnego:
ciśnienie p” =2210,4 [Pa]
gęstość ρ” = 0,0164 [kg/m3]
gęstość powietrza wilgotnego:
ciśnienie
prędkość
liczba Reynoldsa
Dla obliczonej liczby Reynoldsa odczytana z wykresu wartość współczynnika oporu
Cx = 0,83