PNOZ X3 GB

background image

1-1

1

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ X3

Emergency stop relay and safety
gate monitor in accordance with
VDE 0113, 11/98, EN 60204-1, 12/97
and IEC 204-1, 11/98, safety
component in accordance with the
Lift Directive 95/16/EC and EN 81-1/
1998

Features

● Monitored manual or automatic

reset can be selected

● 1 semiconductor output (K1/K2)
● Each AC unit can be operated

with 24 VDC

● Safety gate function with

N/C-N/O combination

● Only dual-channel operation will

detect shorts across the input
contacts

Approvals

Technical Details

PNOZ X3

Electrical Data

Supply Voltage

AC: 24, 42, 48, 110, 115, 120, 230, 240 V

DC: 24 V

Tolerance

-15 % ... +10 % U

B

Power Consumption

Approx.2.5 W/5 VA

Voltage and Current at the Input and

24 VDC, 35 mA

Reset Circuits and Feedback Control Loop

Switching Capability in accordance with

EN 60947-4-1, 10/91

AC1:

240 V/8 A/2000 VA

DC1: 24 V/8 A/200 W

EN 60947-5-1, 10/91

AC15: 230 V/5 A; DC13: 24 V/6A

(DC13: 6 cycles/min.)

Output Contacts

3 safety contacts (N/O),

1 auxiliary contact (N/C)

Contact Fuse Protection

10 A quick or 6 A slow

(EN 60947-5-1, 10/91)

Semiconductor Outputs

24 VDC/20 mA, short-circuit protected

External Supply Voltage

24 VDC ±20 %

Times

Delay-on Energisation

Monitored manual reset: max. 100 ms

Auto./ manual reset: max. 0.3 s

Delay-on De-energisation

With E-STOP: max. 30 ms

With power failure: max. 100 ms

Recovery Time

Approx. 100 ms

Simultaneity channel 1/2

¥

Max. Supply Interruption before De-energisation

Approx. 25 ms

Environmental Data

Ambient Temperature

-25 ... +55 °C

Mechanical Data

Maximum Cross Section of

2 x 1.5 mm

2

or 1 x 2.5 mm

2

External Conductors

Single-core or multi-core

with crimp connectors

Dimensions (H x W x D)

87 x 45 x 121 mm

Weight

375 g

Description

● 45 mm, P-93 housing, DIN-Rail

mounting

● Positive-guided relay outputs:

– 3 safety contacts (N/O)
– 1 auxiliary contact (N/C)

● Connections for

– E-STOP button
– safety gate limit switch
– reset button

● Semiconductor output signals

ready for operation

● LEDs for channel 1, channel 2 and

power

● Increase in the number of

safety contacts available by
connecting expander modules.

Operating Modes

● Single-channel operation
● Dual-channel operation
● Automatic reset
● Monitored manual reset

PNOZ X3

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland

NSG-D-2-036-04/03

Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de

background image

1

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ X3

Internal Wiring Diagram

A1

A2

S13

S14

S12

S21

S34

41

42

S11

S22

S32

S31

13

33

14

34

K1

K2

23

24

&

Y32

Y31

CH1

CH2

Start
Unit

S33

AC

DC

B1

B2

+

-

UB

Input circuit

Reset circuit

Safety

contacts

Auxiliary

contact

Input circuit

External Wiring

● Example 1
Single-channel E-STOP wiring with
automatic reset.

S11 S31

S13

S12

S14

S32

S21

S22

S1

● Example 2
Single-channel E-STOP wiring with
monitored manual reset.

S11 S31

S33

S12

S34

S32

S21

S22

S1

S3

● Example 3
Dual-channel E-STOP wiring with
monitored manual reset.

● Example 4
Single-channel safety gate control
with monitored manual reset.

S32

S34

S33

S31

S11

S22

S12

S21

S1

S3

● Example 5
Dual-channel safety gate control with
monitored manual reset.

● Example 6
Dual-channel safety gate control with
automatic reset.

– Key

S1/2:

E-STOP or safety gate switch

S3:

Reset button

Switch operated

Gate open

Gate closed

S21

S22

S12

S34

S32

S33

S11

S31

S1

S3

S12

S34

S33

S11

S21

S32

S22

S31

S1

S2

S3

S12

S14

S13

S11

S21

S32

S22

S1

S2

S31

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland

NSG-D-2-036-04/03

Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de

background image

1-3

1

● Increase in safety contacts
The number of output contacts can
be increased by using expander
modules or relays/contactors with
positive-guided contacts.

– Ooperation with automatic reset.

– Operation with monitored manual

reset.

14

K5

K6

13

S13

S14

K5

K6

1L1

1L2

14

K5

K6

13

S33

S34

K5

K6

1L1

1L2

S3

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ X3

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland

NSG-D-2-036-04/03

Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de

background image

1

Emergency Stop Relays, Safety Gate Monitors

Category 4, EN 954-1
PNOZ X3

Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland

NSG-D-2-036-04/03

Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de

General Technical Data

Unless stated otherwise in the technical details for the specific unit

Electrical Data

Frequency Range AC

50 ... 60 Hz

Residual Ripple DC

160 %

Contact Material

AgSnO

2

Continuous Duty

100 %

Environmental Data

EMC

EN 50081-1, 01/92, EN 50082-2, 03/95

Vibration in accordance with

Frequency: 10 ... 55 Hz,

EN 60068-2-6, 04/95

Amplitude: 0.35 mm

Climatic Suitability

DIN IEC 60068-2-3, 12/86

Airgap Creepage

DIN VDE 0110 part 1, 04/97

Ambient Temperature

-10 ... +55 °C

Storage Temperature

-40 ... +85 °C

Mechanical Data

Torque Setting on Connection Terminals

0.6 Nm (screws)

Mounting Position

Any

Housing Material

Thermoplast Noryl SE 100

Protection

Mounting: IP 54

Housing: IP 40

Terminal Range: IP 20

The units were tested in accordance with the relevant standards current at
the time of development.

Order References

Type

U

B

Order No.

PNOZ X3

24 V AC/24 V DC

774 310

PNOZ X3

42 V AC/24 V DC

774 311

PNOZ X3

48 V AC/24 V DC

774 312

PNOZ X3

110 V AC/24 V DC

774 314

PNOZ X3

115 V AC/24 V DC

774 315

PNOZ X3

120 V AC/24 V DC

774 316

PNOZ X3

230 V AC/24 V DC

774 318

PNOZ X3

240 V AC/24 V DC

774 319


Wyszukiwarka

Podobne podstrony:
PNOZ X3 1 GB
pnoz x3p gb B5VW75QW7OGZ3YAVF6G43JUJXVPZSFBDAWURFWI
pnoz xe1 gb[1] OHVH62VRNRX27UG45CP4SMHI65HT275IHJKNDPA
PNOZ EX GB
PNOZ XV2P GB
PNOZ X3P GB
PNOZ X2P GB
PNOZ 16SP GB
PNOZ X3 Data sheet 1002239 EN 02
PNOZ XE2 GB
PNOZ XV2 1 GB
PNOZ XV3 GB
PNOZ E1P GB
PNOZ 2VQ GB
PNOZ XM1 GB
PNOZ X2C GB
PNOZ 11 GB

więcej podobnych podstron