OBLICZANIE SZUKANYCH PRZEMIESZCZEŃ OD OBCIĄŻENIA SIŁAMI
PRZEMIESZCZENIA OD OBCIĄŻEŃ SIŁAMI |
---|
OZNACZENIE PRETA |
A-4 |
A-6 |
A-5 |
6,0-5,0 |
4,0-5,0 |
4,0-3,0 |
5,0-1,0 |
5,0-3,0 |
1,0-3,0 |
1,0-2,0 |
3,0-2,0 |
3-B |
B-2 |
więź sprężysta |
SKŁADOWA POZIOMA PRZESUŃIĘCIA WĘZŁA NR 6 WYNOSI: ΔF = -0,00868 m = -0,868 cm
OBLICZANIE SZUKANYCH PRZEMIESZCZEŃ OD ZMIAN TEMPERATURY
PRZEMIESZCENIA OD ZMIAN TEMPERATURY |
---|
OZNACZENIE PRETA |
A-4 |
A-6 |
A-5 |
6,0-5,0 |
4,0-5,0 |
4,0-3,0 |
5,0-1,0 |
5,0-3,0 |
1,0-3,0 |
1,0-2,0 |
3,0-2,0 |
3-B |
B-2 |
SKŁADOWA POZIOMA PRZESUŃIĘCIA WĘZŁA NR 6 WYNOSI: ΔT = 0,00640 m = 0,64 cm
OBLICZANIE SZUKANYCH PRZEMIESZCZEŃ OD BŁĘDÓW MONTAŻU I PRZEMIESZCZEŃ PODPÓR
PRZEMIESZCZENIA PODPÓR I OD BŁĘDU MONTAŻU |
---|
OZNACZENIE PRETA |
A-4 |
A-6 |
A-5 |
6,0-5,0 |
4,0-5,0 |
4,0-3,0 |
5,0-1,0 |
5,0-3,0 |
1,0-3,0 |
1,0-2,0 |
3,0-2,0 |
3-B |
B-2 |
SKŁADOWA POZIOMA PRZESUŃIĘCIA WĘZŁA NR 6 WYNOSI: ΔR = -0,59 m = 5,9 cm