89 TransAlp Manualºttery Charging System 6
BATTERY/CHARGING SYSTEM
When the timer reaches the "Trickle" position, the charging cycle is complete. Tum the Power Switch OFF and disconnect the clamps.
NOTĘ
• The charger will automatically switch to the Trickle modę after the set charging time has elapsed.
Re-test the battery using the Honda Battery Tester and re-charge if necessary using the above steps.
NOTĘ
INSTALLATION
Install the battery in the reverse order of the removal.
After installing the battery, coat the terminals with clean grease.
CAUTION
• Ronie the breather tubę as shown on the battery cautłon labę/.
• Make surę the breather tubę does not bend, after the battery has been instal/ed into the case.
|
[A CAUTION
(2) PIPING AS SHOWN BEkOW
(3) BATT. BREATHER TUBĘ (4> BATT. ELBOW | |
|
(bHllMbtKi i Mt / / R ATT RRFATHFR r1. |
Tl |
JBE SECURELYI ^ M
<6) CLIP \ni
(o# w |
|
CHARGING SYSTEM
NOTĘ
• When inspecting the charging system, check the system components and lines step-by-step according to the troubleshooting on page 16-2.
• With large capacity circuits that exceed the ratings of the fuse contained in the tester, measuring errors can cause damage to testing equipment.
Before starting each test, set the tester at the high capacity rangÄ™ first, then adjust it to the smali capacity circuits rangÄ™ in order that you have the correct rangÄ™.
LEAKAGE INSPECTION
CAUTION
• When measuring smali capacity circuits, keep the ignition switch off. If the switch is suddenly turned on during a test, the tester fuse may blow.
Check the battery ampere leakage before making the regulated voltage inspection.
Turn the ignition switch off and disconnect the battery nega-tive cable from the battery.
Connect the tester between the negative cable and the nega-tive battery terminal.
The tester should indicate within 1 mA with the ignition switch OFF.
16-6
(2) BATTERY NEGATIN/E CABLE
1
For accurate test results, let the battery cool for at least ten minutes or until gassing subsides after charging.
Wyszukiwarka
Podobne podstrony:
89 TransAlp Manual?ttery Charging System 1 16. BATTERY/CHARGING SYSTEM SERVICE INFORMATION 16-1 C89 TransAlp Manual?ttery Charging System 3 BATTERY/CHARGING SYSTEM BATTERY/CHARGING SYSTEMBATTERY A89 TransAlp Manual?ttery Charging System 4 BATTERY/CHARGING SYSTEMTESTING NOTĘ • Refer to the Servi89 TransAlp Manual?ttery Charging System 5 BATTERY/CHARGING SYSTEM BATTERY/CHARGING SYSTEM I-1 GREE89 TransAlp Manual?ttery Charging System 7 BATTERY/CHARGING SYSTEMREGULATED VOLTAGE INSPECTION £ i89 TransAlp Manual?ttery Charging System 8 BATTERY/CHARGING SYSTEMUNIT INSPECTION Provided the Circ89 TransAlp Manual Cooling System 5 1 SERN/ICE INFORMATION 5-1 TROUBLESHOOTING 5-1 SYSTEM TESTING89 TransAlp Manual Cooling System 5 COOLING SYSTEMRESERVE TANK REMOVAL Remove the starter motor (pa89 TransAlp Manual Cooling System 5 2 COOLING SYSTEMSYSTEM TESTING COOLANT MIXTURE Test the coolant89 TransAlp Manual Cooling System 5 3 COOLING SYSTEMCOOLANT REPLACEMENT Awarning • The engłne must b89 TransAlp Manual Cooling System 5 4 COOLING SYSTEMINSPECTION Inspect the thermostat visually for d89 TransAlp Manual Cooling System 5 5 COOLING SYSTEM COOLING SYSTEM C r* r THERMOSENSORREMOVAL Drai89 TransAlp Manual Cooling System 5 6 COOLING SYSTEMRADIATORREMOVAL Drain the coolant (page 5-3). Re89 TransAlp Manual Cooling System 5 7 COOLING SYSTEM Remove the nut and fan. Remove the fan motor mo89 TransAlp Manual Cooling System 5 8 COOLING SYSTEMWATER PUMP MECHANICAL SEAL INSPECTION Remove the89 TransAlp Manual Cooling System 5 9 COOLING SYSTEMINSTALLATION Install a new O-ring on the water p89 TransAlp Manual Fuel System 4 1 4. FUEL SYSTEM SERVICE INFORMATION 4-1 CARBURETOR89 TransAlp Manual Fuel System 4 FUELSYSTEM (1) FLOAT CHAMBERFLOAT CHAMBER, FLOAT AND JETS Remove t89 TransAlp Manual Fuel System 4 FUELSYSTEM Inspect the float valve seat and filter for grooves, niwięcej podobnych podstron