PNOZmulti
Legend
Failsafe - possible
Standard - possible
8 1
2 3 4 5
6
7
Product portfolio - PNOZmulti product range
Features
Description
Order no.
Fieldbus
Base unit
1 2 3 4 5 6 7 8
Basic features
Base unit, from 3 ... 6 safety functions
20 digital inputs, 4 digital semiconductor outputs, 2 relay outputs PNOZ m0p
773 110
only fieldbus modules can be connected
* * * * * * * *
1
Base unit, from 4 safety functions and for standard
control functions
20 digital inputs, 4 digital semiconductor outputs, 2 relay outputs PNOZ m1p
773 100
depends on the expansion module
Base unit, specifically for press applications
20 digital inputs, 4 digital semiconductor outputs, 2 relay outputs PNOZ m2p
773 120
depends on the expansion module
Standard - expansion modules
Input module
8 inputs
PNOZ mi2p
773 410
max. 8
7 Output module
16 digital auxiliary outputs in semiconductor technology
PNOZ mc1p
773 700
max. 8
Fieldbus modules
8 Fieldbus module PROFIBUS-DP
Slave on PROFIBUS-DP
PNOZ mc3p
773 221
max. 1
Fieldbus module Device-Net
Slave on Device-Net
PNOZ mc4p
773 722
max. 1
Fieldbus module Interbus
Slave on Interbus
PNOZ mc5p
773 723
max. 1
Fieldbus module CANopen
Slave on CANopen
PNOZ mc6p
773 724
max. 1
Fieldbus module CC-Link
Slave on CC-Link
PNOZ mc7p
773 726
max. 1
Failsafe - expansion modules
2 Safe input module
8 safe inputs
PNOZ mi1p
773 400
max. 8
3 Semiconductor output module, single-pole
4 digital semiconductor outputs, single-pole
PNOZ mo1p
773 500
max. 6
Semiconductor output module, dual-pole
2 digital semiconductor outputs, dual-pole (cat. 4)
PNOZ mo3p
773 510
4 Relay output module
2 relay outputs
PNOZ mo2p
773 520
max. 6
5 Relay output module
4 relay outputs
PNOZ mo4p
773 536
max. 6
6 Standstill / speed monitoring module
2 input device PNP inputs or 2 encoder inputs
PNOZ ms1p
773 800
max. 4 = 8 axes
Standstill / speed monitoring module
2 input device PNP inputs or 2 encoder inputs, independent from
the supply voltage on the incremental encoder
PNOZ ms2p
773 810
max. 4 = 8 axes
* Fieldbus modules can be connected, no other expansion modules can be connected
Status: December 2004
Module configuration
No. of modules on the base unit
Overview of the PNOZmulti modular safety system
Pilz GmbH & Co. KG Safe Automation
PNOZmulti, many functions - one solution!