Service Information Bulletin
Model : KU990/U990
LG Electronics
Revision : V1.0 (13 / Aug / 2008)
LGE Internal Use Only
2
LGE Internal Use Only
No
Date
Revision
Country
Carrier
Description
Page
1
13 / Aug /
2008
1.0
Global
All
Over current, Burning smell,
smoking
Page.3
2
3
4
5
Change History
Contact Point : Jeffrey KIm (jaehyunk@lge.com)
3
LGE Internal Use Only
Model
KU990/U990
Date
13 / Aug / 2008
Country /
Carrier
Global / All Carriers
Failure
Info
Failure Symptom by Customer
Root Cause
Factory Modification Info.
1. Battery short life time
2. Burning smell, smoking
and crackling noise
over-current caused by
abnormal charging circuit on
strobe module
Modification must be applied t
o S/N
: from Apr. to Jul. 2008
Change History
Repair Guide
Notice) If you don't repair with this guide, you
should
check & test the other point is NOT mentioned on
this SIB
Strobe Module Issue
[
□ SW □ HW
]
Modification Type (Solution)
Part Information
Category
Old Strobe Module
New Strobe
Module
Part No.
SMZY0016801
SMZY0016801
Silicon
Color
Gray
White
Feature
In case you receive the defected phone like this symptom,
follow below guide
1. Check production month on Serial No. of phone label
2. If the production month is between Apr and Jul.
you should check a capacitor on
strobe module is damaged like picture
3. If it is damaged, you should
replace it with new one
4. After replacement, you should
download the latest SW.
5. After reassembly, you should check & test fully
Check Flow
Code Guide
Defect Code : P5, Repair Code :
F5
• When capacitor is damaged, replace with new one
• Download the improving SW version