ELECTRIC STARTER
o
If the switch 'CLICK' is not heard, measure the voltage be-tween the yellow/red 1+) and green/red (-) wires of the relay connector. The battery voltage should come when the starter switch button is depressed with the ignition switch ON and neutral position.
Perform the following inspection if the battery voltage ap-peared between the yellow/red and green/red wires.
Remove the starter relay switch.
Connect an ohmmeter to the starter relay switch large termi-nals.
Connect a fully charged 1 2 V battery positive wire to the starter relay switch Yellow/Red wire terminal and battery negative wire to the Green/Red wire terminal.
Check for continuity between the starter relay switch termi-nals.
There should be continuity while 12 V battery is connected to the starter relay switch terminals and should be no continuity when the battery is disconnected.
CLUTCH DIODĘ
NOTĘ
• Clutch diodę is located in the fuse box.
Check for continuity with an ohmmeter at the connector.
NORMAL DIRECTION: CONTINUITY REVERSE DIRECTION: NO CONTINUITY
18-7