300 M. Kędzierski, A. Fryśkowska, M. Wilińska
cd. tabeli 10
T4 |
ScanWorldl |
ScanWorld7 |
0,008 |
T3 |
ScanWorldl |
ScanWorld8 |
0,006 |
T4 |
ScanWorldl |
ScanWorld8 |
0,006 |
T3 |
ScanWorldl |
ScanWorld9 |
0,005 |
T3 |
ScanWorld2 |
ScanWorld5 |
0,006 |
Tl |
ScanWorld2 |
ScanWorld5 |
0,005 |
T3 |
ScanWorld2 |
ScanWorld7 |
0,007 |
T3 |
ScanWorld2 |
ScanWorld8 |
0,003 |
T3 |
ScanWorld2 |
ScanWorld9 |
0,002 |
T3 |
ScanWorld5 |
ScanWorldl |
0,013 |
T4 |
ScanWorld5 |
ScanWorld8 |
0,008 |
T3 |
ScanWorld5 |
ScanWorld8 |
0,008 |
T3 |
ScanWorld5 |
ScanWorld9 |
0,008 |
Tl |
ScanWorld5 |
ScanWorld7 |
0,014 |
T4 |
ScanWorld5 |
ScanWorldl |
0,007 |
T4 |
ScanWorld7 |
ScanWorld8 |
0,003 |
T3 |
ScanWorldl |
ScanWorld8 |
0,005 |
T6U |
ScanWorld7 |
ScanWorld8 |
0,003 |
T6L |
ScanWorldl |
ScanWorld8 |
0,004 |
T3 |
ScanWorld7 |
ScanWorld9 |
0,005 |
T6U |
ScanWorld7 |
ScanWorld9 |
0,003 |
T6L |
ScanWorldl |
ScanWorld9 |
0,004 |
T3 |
ScanWorld8 |
ScanWorld9 |
0,001 |
T6L |
ScanWorld8 |
ScanWorld9 |
0,002 |
Największy błąd średni, równy 0,014 metra, wystąpił przy wyrównaniu pomiarów celu o identyfikatorze Tl, przy łączeniu środowisk ScanWorld5 i ScanWorld7. Spowodowane było to większą odległością celów HDS od skanera niż przy pozostałych tarczach. Całkowity błąd średni wyrównania wszystkich środowisk skanowania, biorących w nim udział, wyniósł 0,006 metra.