Własności statyczne przetworników pomiarowych
Czułość:
$$S = \frac{\text{dU}}{\text{dα}} = \frac{U_{\max}}{\alpha_{\max}} = \frac{62}{300} = 0,20667$$
Stała przetwornika idealnego
$$C = \frac{1}{S} = 4,8387$$
α | Uro | Umal | Uteo | Usr |
---|---|---|---|---|
0 | 0 | 3,36 | 0 | 1,68 |
10 | 1,59 | 5,25 | 2,0667 | 3,42 |
20 | 3,46 | 7,29 | 4,1334 | 5,375 |
30 | 4,99 | 9,12 | 6,2001 | 7,055 |
40 | 6,58 | 11,14 | 8,2668 | 8,86 |
50 | 7,63 | 13,21 | 10,3335 | 10,42 |
60 | 9,12 | 14,97 | 12,4002 | 12,045 |
70 | 10,8 | 17,02 | 14,4669 | 13,91 |
80 | 11,83 | 18,27 | 16,5336 | 15,05 |
90 | 13,67 | 19,7 | 18,6003 | 16,685 |
100 | 15,06 | 21,15 | 20,667 | 18,105 |
110 | 17 | 22,3 | 22,7337 | 19,65 |
120 | 18,93 | 23,5 | 24,8004 | 21,215 |
130 | 21,16 | 24,41 | 26,8671 | 22,785 |
140 | 22,87 | 25,14 | 28,9338 | 24,005 |
150 | 24,73 | 25,97 | 31,0005 | 25,35 |
160 | 26,81 | 26,97 | 33,0672 | 26,89 |
170 | 28,61 | 28,78 | 35,1339 | 28,695 |
180 | 30,68 | 30,72 | 37,2006 | 30,7 |
190 | 32,38 | 32,96 | 39,2673 | 32,67 |
200 | 34,65 | 34,86 | 41,334 | 34,755 |
210 | 36,58 | 37,18 | 43,4007 | 36,88 |
220 | 38,76 | 38,7 | 45,4674 | 38,73 |
230 | 40,8 | 40,8 | 47,5341 | 40,8 |
240 | 42,6 | 42,7 | 49,6008 | 42,65 |
250 | 45,1 | 45,1 | 51,6675 | 45,1 |
260 | 47,2 | 47,3 | 53,7342 | 47,25 |
270 | 48,9 | 49,2 | 55,8009 | 49,05 |
280 | 51 | 51,3 | 57,8676 | 51,15 |
290 | 53,2 | 53,4 | 59,9343 | 53,3 |
300 | 55,1 | 55,1 | 62,001 | 55,1 |